UNISONIC TECHNOLOGIES CO., LTD 12N30

UNISONIC TECHNOLOGIES CO., LTD
12N30
Preliminary
Power MOSFET
12A, 300V N-CHANNEL
POWER MOSFET

DESCRIPTION
The UTC 12N30 is an N-channel mode power MOSFET using
UTC’ s advanced technology to provide customers with planar stripe
and DMOS technology. This technology specializes in allowing a
minimum on-state resistance and superior switching performance. It
also can withstand high energy pulse in the avalanche and
commutation mode.
The UTC 12N30 is universally applied in electronic lamp ballast
based on half bridge topology and high efficient switched mode
power supply.

FEATURES
* RDS(ON) < 0.47Ω @ VGS=10V, ID=12A
* High switching speed

SYMBOL
2.Drain
1.Gate
3.Source

ORDERING INFORMATION
Ordering Number
Note:

12N30G-TN3-R
Pin Assignment: G: Gate D: Drain
Package
TO-252
1
G
Pin Assignment
2
3
D
S
Packing
Tape Reel
S: Source
MARKING
www.unisonic.com.tw
Copyright © 2015 Unisonic Technologies Co., Ltd
1 of 5
QW-R502-787.b
12N30

Preliminary
Power MOSFET
ABSOLUTE MAXIMUM RATINGS (TC=25°C, unless otherwise specified)
PARAMETER
SYMBOL
RATINGS
UNIT
Drain-Source Voltage
VDSS
300
V
Gate-Source Voltage
VGSS
±20
V
ID
12
A
Continuous (TC=25°C)
Drain Current
Pulsed (Note 2)
IDM
48
A
Single Pulsed Avalanche Energy
EAS
300
mJ
Power Dissipation
PD
83
W
Junction Temperature
TJ
+150
°C
Storage Temperature
TSTG
-55~+150
°C
Note: 1. Absolute maximum ratings are those values beyond which the device could be permanently damaged.
Absolute maximum ratings are stress ratings only and functional device operation is not implied.
2. Repetitive Rating: Pulse width limited by maximum junction temperature
3. Starting TJ=25°C, IAS=12A, VDD=50V, L=4.1mH.

THERMAL DATA
PARAMETER
Junction to Ambient
Junction to Case

SYMBOL
θJA
θJC
RATINGS
62.5
1.5
UNIT
°C/W
°C/W
ELECTRICAL CHARACTERISTICS (TC=25°C, unless otherwise noted)
PARAMETER
SYMBOL
TEST CONDITIONS
OFF CHARACTERISTICS
Drain-Source Breakdown Voltage
BVDSS
ID=250µA, VGS=0V
Drain-Source Leakage Current
IDSS
VDS=300V, VGS=0V
Forward
VGS=+20V, VDS=0V
Gate- Source Leakage Current
IGSS
Reverse
VGS=-20V, VDS=0V
ON CHARACTERISTICS
Gate Threshold Voltage
VGS(TH)
VDS=VGS, ID=250µA
Static Drain-Source On-State Resistance
RDS(ON)
VGS=10V, ID=6A
DYNAMIC PARAMETERS
Input Capacitance
CISS
VGS=0V, VDS=25V, f=1.0MHz
Output Capacitance
COSS
Reverse Transfer Capacitance
CRSS
SWITCHING PARAMETERS
Total Gate Charge
QG
VDD=50V, VGS=10V, ID=1.3A
Gate-Source Charge
QGS
IG=100µA (Note 1, 2)
Gate-Drain Charge
QGD
Turn-ON Delay Time
tD(ON)
Rise Time
tR
VDD=30V, ID=0.5A, RG=25Ω
VGS=10V (Note 1, 2)
Turn-OFF Delay Time
tD(OFF)
Fall-Time
tF
SOURCE- DRAIN DIODE RATINGS AND CHARACTERISTICS
Drain-Source Diode Forward Voltage
VSD
IS=12A, VGS=0V
Maximum Body-Diode Continuous Current
IS
Maximum Body-Diode Pulsed Current
ISM
Notes: 1. Pulse Test: Pulse width ≤ 300µs, Duty cycle ≤ 2%
2. Essentially independent of operating temperature
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
MIN TYP MAX UNIT
300
2.0
V
1
µA
+100 nA
-100 nA
4.0
0.40 0.47
V
Ω
810
165
65
pF
pF
pF
24
5
5.6
42
50
137
52
nC
nC
nC
ns
ns
ns
ns
1.4
12
48
V
A
A
2 of 5
QW-R502-787.b
12N30

Preliminary
Power MOSFET
TEST CIRCUITS AND WAVEFORMS
D.U.T.
+
VDS
-
+
-
L
RG
Driver
VGS
VDD
* dv/dt controlled by RG
* ISD controlled by pulse period
* D.U.T.-Device Under Test
Same Type
as D.U.T.
Peak Diode Recovery dv/dt Test Circuit
VGS
(Driver)
Period
D=
P.W.
P. W.
Period
VGS= 10V
IFM, Body Diode Forward Current
ISD
(D.U.T.)
di/dt
IRM
Body Diode Reverse Current
Body Diode Recovery dv/dt
VDS
(D.U.T.)
VDD
Body Diode
Forward Voltage Drop
Peak Diode Recovery dv/dt Waveforms
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
3 of 5
QW-R502-787.b
12N30

Preliminary
Power MOSFET
TEST CIRCUITS AND WAVEFORMS
VDS
90%
VGS
10%
tD(ON)
tD(OFF)
tF
tR
Switching Test Circuit
Switching Waveforms
BVDSS
IAS
ID(t)
VDS(t)
VDD
tp
Unclamped Inductive Switching Test Circuit
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
Time
Unclamped Inductive Switching Waveforms
4 of 5
QW-R502-787.b
12N30
Preliminary
Power MOSFET
UTC assumes no responsibility for equipment failures that result from using products at values that
exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or
other parameters) listed in products specifications of any and all UTC products described or contained
herein. UTC products are not designed for use in life support appliances, devices or systems where
malfunction of these products can be reasonably expected to result in personal injury. Reproduction in
whole or in part is prohibited without the prior written consent of the copyright owner. The information
presented in this document does not form part of any quotation or contract, is believed to be accurate
and reliable and may be changed without notice.
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
5 of 5
QW-R502-787.b