AT-320240Q4 - DEMA Electronic AG

A MP I R E
SPECIFICATIONS FOR
LCD MODULE
CUSTOMER
CUSTOMER PART NO.
AMPIRE PART NO.
AT-320240Q4
(Built-in Controller)
APPROVED BY
DATE
APPROVED BY
Date : 2006/9/12
CHECKED BY
AMPIRE CO., LTD.
ORGANIZED BY
1
RECORD OF REVISION
Revision Date Page
2006/9/12
Date : 2006/9/12
--
Contents
New Release
AMPIRE CO., LTD.
Editor
Tony
2
1
FEATURES
(1)
Display format: 320 × 240 dot- matrix, 1/240 duty.
(2)
Construction: FSTN LCD, TAB type LCD driver and PCB.
(3)
Option: EL backlight, EL driver, Touch Panel, Touch Panel controller. (Default built- in
EL driver while choosing EL backlight)
(4)
Controller : RA8835
(5)
New Driving Method CMOS LCD Driver for Low Power Consumption Driving.
(6)
5V or 3.3V single power input. Built- in specific power supplies circuit for LCD
driving. Ultra Low Power Consumption.
(7)
Normal / Extended temperature type.
(8)
Portrait(Default) or Landscape Display Type Selectable by Jumper Setting.
(9)
80 or 68 Family MPU Selectable by Jumper Setting
1.1 Advantage than AT-320240Q
(1) New power supply circuit. More excellent power saving and better display.
(2) New T/P controller TSC2046 to replace the unavailable TR88L803.
(3) New EL driver IMP528 to improve the EL back- light brightness.
2 NUMBERING SYSTEM
AT-320240Q4 _ _ _ _ - _ - _
1234 5 6
No
1
2
3
4
5
6
Code Value
F
A
I
None
E
None
B
W
03
04
05
None
H
Date : 2006/9/12
Description
FSTN type LCD
Reflective type / 6:00 view
Transflective type / 6:00 view
Without backlight
EL
Without backlight
Blue
White
Without Touch Panel
With Touch Panel
With Touch Panel and T/P controller
Normal temperature type
Extended temperature type
AMPIRE CO., LTD.
Remark
LCD Type
Polarizer / Viewing Angel
Backlight type
Backlight color
Touch Panel option
LCM temperature type
3
3 MECHANICAL DATA
Parameter
Stand Value
Unit
Dot size
0.225(W) × 0.225(H)
mm
Dot pitch
0.24(W) × 0.24(H)
mm
Viewing area
62.0 (W) × 81.8 (H)
mm
Module size
73.0(W) × 92.2(H) × 7.6 max (T)
mm
Module size
(w/ Touch panel)
73.0(W) × 92.2(H) × 9.0 max (T)
mm
4 ABSOLUTE MAXIMUM RATINGS
Parameter
Symbol
Min
Max
Unit
Logic Circuit Supply Voltage
VCC-VSS
-0.3
7.0
V
LCD Driving Voltage
--
-0.3
26.0
V
Input Voltage
VI
-0.3
VDD+0.3
V
Operating Temp.
TOP
0
50
°C
Storage Temp.
TSTG
-20
70
°C
Operating Temp.
TOP
-20
70
°C
Storage Temp.
TSTG
-30
80
°C
Normal
temp. type
Extended
temp. type
Date : 2006/9/12
AMPIRE CO., LTD.
4
5 ELECTRO-OPTICAL CHARACTERISTICS
Parameter
Symbol
Logic Circuit
Supply Voltage
Condition Min
Typ
Max
----- Electronic Characteristics ----2.6
-5.5
VDD-VSS
--20 °C
--
Unit
V
25 °C
22.7
20.7
23.9
21.8
25.1
22.9
70 °C
18.8
19.8
20.8
VIH
--
0.7 VDD
--
VDD
VIL
ICC
--
VSS
--
-20
--
--
50
Contrast
CR
----- Optical Cha racteristics ----FSTN type
2
5
Rise Time
tr
25°C
--
175
255
ms
Fall Time
tf
25°C
--
380
570
ms
Viewing Angle
Range
θf
25°C &
40
--
--
θb
CR≥2
25
--
--
θl
40
--
--
θr
30
--
--
--
70
--
LCD Driving
Voltage
Input Voltage
Logic Supply
Current
Supply Current
with EL driver
Frame Frequency
fF
25°C
Note
-20 ~ 70 °C for
Extended Temp.
type
V
V
0.3 VDD V
-mA
--
mA Logic + EL driver
Note 1
Note 2
Note 3
Deg.
Hz
EL Back-light Electrical Specification
Parameter
Specification
Unit
Color
Blue / White
-
Voltage
Vrms = 60
V(AC)
Frequency
Current Density
Sine Wave = 380
0.12
Hz
mA / cm2
Bare EL Initial Brightness
15
cd / m2
LCM Initial Brightness
5
cd / m2
(NOTE 1) Contrast ratio :
CR = (Brightness in OFF state) / (Brightness in ON state)
Date : 2006/9/12
AMPIRE CO., LTD.
5
( NOTE 2 ) Response time :
(NOTE 3) Viewing angle
Touch Panel Electrical Specification
Parameter
ON Resistance
Insulating Resistance
Chattering
Date : 2006/9/12
Specification
400 Ω ~ 800 Ω
260 Ω ~ 600 Ω
More than 10MΩ
Less Than 15 ms
AMPIRE CO., LTD.
Condition
X Axis
Y Axis
DC 25 V
100KΩ Pull- Up
6
6 BLOCK DIAGRAM
From
MPU
FLM
/RESET
/RD
/WR Controller
RA8835
/CS
A0
DB0~7
LP, M, YDIS
COM.
Driver
LCD Panel
240
320 x 240 Dots
320
SRAM
SEG.
Driver
CP,D0~D3
* Please use the YDIS pin and the inner command of the RA8835 to control Display On/Off.
Power Supply Example
VCC
LCD MODULE
New driving
method LCD
driver
R1
VCTL
VR
R2
VSS
0V
LCD power
circuit
Note: VR = 20 K, VCTL =0.3~0.5V
Date : 2006/9/12
AMPIRE CO., LTD.
7
7 INTERFACE DEFINITION
PIN NO.
1
SIGNAL
/RESET
LEVEL
FUNCTION
H/L
Reset Signal
80 Series: Read Signal
H/L
68 Series: Enable Signal(E)
80 Series: Write Signal
H/L
68 Series: R/W Signal
H/L
Chip Select Signal
H/L
Data Type Selection
2
/RD
3
/WR
4
5
/CS
A0
6 ~ 13
DB0~DB7
H/L
14
15
VCC
VSS
-
Power Supply for Logic (+5V or 3.3V)
Power Supply(Ground : 0V)
16
VCTL
-
Contrast Adjustment Input
17
EL_ON
H/L
Data Input(8 bits)
EL On/Off Signal; H: EL On L: EL Off
Serial Clock
18*
SK / X1
Touch Panel Left Signal in X Axis
Data Output
19*
DO / X2
Touch Panel Right Signal in X Axis
Data In
20*
DI / Y1
Touch Panel Upper Signal in Y Axis
Chip Select
21*
CS / Y2
Touch Panel Lower Signal in X Axis
22*
INT
Interrupt
EL power input while using external EL driver
23,24
EL1,EL2
(Switch the EL_JP1, EL_JP2)
* 18~22 : SK, DO, DI, CS, INT for Touch Panel controller TSC2046
/ X1, X2, Y1, Y2 for Touch Panel (without TSC2046)
Date : 2006/9/12
AMPIRE CO., LTD.
8
8 TIMING CHARACTERISTICS
8.1
8080 Family Interface Timing
Parameter
Condition
Symbol
Min
Address Hold Time
tAH8
10
Address Setup Time
tAW8
0
System Cycle Time
tCYC
Note
Strobe Pulse Width
CL=100 pF
tOC
150
VDD=2.7~4.5
Data Setup Time
tDS8
120
Data Hold Time
tDH8
5
/RD Access Time
tACC8
Output Disable Time
tOH8
10
Note: For memory control and system control commands:
tCYC8=2tC+tOC+tCEA+75 > tACV +245
For all other commands:
tCYC8=4tC+tOC+30
Max
80
55
Unit
ns
ns
ns
ns
ns
ns
ns
ns
Remark
A0,/CS
/WR,/RD
DB0~DB7
A0,/CS
/WR,/RD
DB0~DB7
(Write)
DB0~DB7
(Read)
Date : 2006/9/12
AMPIRE CO., LTD.
9
8.2
6800 Family Interface Timing
Parameter
Condition
Symbol
Min
System Cycle Time
tCYC6
Note
Address Setup Time
tAW6
10
Address Hold Time
tAH6
0
Data Setup Time
CL=100 pF
tDS6
120
VDD=2.7~4.5
Data Hold Time
tDH6
0
Output Disable Time
tOH6
10
Access Time
tACC6
Enable Pulsewidth
tEW
150
Note: For memory control and system control commands:
tCYC6=2tC+tEW+tCEA+75 > tACV +245
For all other commands:
tCYC6=4tC+tEW+30
Max
75
130
-
Unit
ns
ns
ns
ns
ns
ns
ns
ns
Remark
A0,/CS,
R/W
DB0~DB7
E
E
R/W
A0, /CS
DB0~DB7
(Write)
DB0~DB7
(Read)
AC Electrical Characteristics
Date : 2006/9/12
AMPIRE CO., LTD.
10
9 INSTRUCTION SET
Code
Class
Command
Hex
/RD /WR A0
SYSTEM
System SET
Control
SLEEP IN
D7
D6
D5
D4
D3
D2
D1
D0
1
0
1
0
1
0
0
0
0
0
0
1
0
1
0
1
0
1
0
0
1
Command Description
Command read
parameters
Number of
Section
byters
40 Initialized Device and display
8
8.2.1
1
53 Enter Standby mode
0
8.2.2
58, Enable and disable display and
59 display flashing
44 set Display start address and
display regions
1
8.3.1
10
8.3.2
5D Set cursor byte
2
8.3.3
5C Set start address of character
generator RAM
CD CD 4C Set direction of cursor
to movement
1
0
4F
2
8.3.6
0
8.3.4
DISP
ON/OFF
1
0
1
0
1
0
1
1
0
0
D
SCROLL
1
0
1
0
1
0
0
0
1
0
0
CSRFORM
1
0
1
0
1
0
1
1
1
0
1
Display CGRAM
Control ADDR.
1
0
1
0
1
0
1
1
1
CSRDIR
1
0
1
0
1
0
0
1
1
HDOT SCR
1
0
1
0
1
0
1
1
OVLAY
1
0
1
0
1
0
1
1
Drawing CSRW
Control
CSRR
1
0
1
0
1
0
0
1
0
1
0
1
0
Memory MWRITE
Control
MREAD
1
0
1
0
1
1
0
1
0
1
0
0
1
0
5A set horizontal scroll position
1
8.3.7
0
1
1
5B set display overlay format
1
8.3.5
0
1
1
0
46 set cursor address
2
8.4.1
0
0
1
1
1
47 read cursor address
2
8.4.2
0
0
0
0
1
0
42 write to display memory
-
8.5.1
0
0
0
0
1
1
43 read from display memory
-
8.5.2
Note:
1. In general, the internal registers of the RA8835 are modified as each command parameter
is input. However, the microprocessor does not have to set all the parameters of a
command and may send a new command before all parameters have been input. The
internal registers for the parameters that have been input will have been changed but the
remaining parameter registers are unchanged.
2 bytes parameters( where two bytes are treated as 1 data item) are handled as following:
a. CSRW, CSRR: Each byte is processed individually. The microprocessor may read or
write just the low byte of the cursor address.
b. SYSTEM SET, SCROLL, CGRAM ADR. : Both parameter bytes are processed together.
If the command is changed after half of the parameter has been input, the single byte is
ignored.
2. APL and APH are 2-byte parameters, but are treated as two 1-byte parameters.
3. Please refer to RA8835 LCD Controller Data Book for detail.
Date : 2006/9/12
AMPIRE CO., LTD.
11
10 INNER DATA FORMAT
COM1
COM240
#1
D3
D3
D3
D3
#2
D2
D2
D2
D2
D1
D1
D1
D1
D0
D0
D0
D0
D3
#320
D3
D2
D2
D2
D1
D1
D1
D0
D0
D0
Portrait Display Type (Top View)
Date : 2006/9/12
AMPIRE CO., LTD.
12
SEG1
SEG320
#1
D3
D2
D1
D0
D3
D2
#2
D3
D2
D1
D0
D3
#240
D3
D2
D1
D0
D3
-
D3
D2
D1
D0
D2
D3
D2
D1
D0
D2
D3
D2
D1
D0
Landscape Display Type(Top View)
* Regardless Portrait or Landscape type, both are 1/240 duty. The only difference is the
opposite scan direction on Common driver. The character mode of RA8835 could only be
used on Landscape type. The character will be Mirrored on Portrait type.
11 JUMPER SETTING
Item
Option
Jumper Setting
Display Type
Portrait (default)
Landscape
80 family (default)
Pin 1,2 short on JP1&JP2
Pin 2,3 short on JP1&JP2
Pin 1,2 short on JP4
68 family
Pin 2,3 short on JP4
MPU
Date : 2006/9/12
AMPIRE CO., LTD.
Remark
13
12 QUALITY AND RELIABILITY
12.1 TEST CONDITIONS
Tests should be conducted under the following conditions :
Ambient temperature : 25 ± 5°C
Humidity
: 60 ± 25% RH.
12.2
SAMPLING PLAN
Sampling method shall be in accordance with MIL-STD-105E , level II, normal
single sampling plan .
12.3 ACCEPTABLE QUALITY LEVEL
A major defect is defined as one that could cause failure to or materially reduce the
usability of the unit for its intended purpose. A minor defect is one that does not materially
reduce the usability of the unit for its intended purpose or is an infringement from established
standards and has no significant bearing on its effective use or operation.
12.4 APPEARANCE
An appearance test should be conducted by human sight at approximately 30 cm
distance from the LCD module under flourescent light. The inspection area of LCD panel
shall be within the range of following limits.
Date : 2006/9/12
AMPIRE CO., LTD.
14
12.5 INSPECTION QUALITY CRITERIA
Item
Description of defects
Function
Dimension
Black spots
Short circuit or Pattern cut
Deviation from drawings
Ave . dia . D
area A
area B
Disregard
D≤0.2
3
4
0.2<D≤0.3
2
3
0.3<D≤0.4
0.4<D
0
1
Width W, Length L
A
B
disregard
W≤0.03
3
4
0.03<W≤0.05
1
1
0.05<W≤0.07 , L≤3.0
See line criteria
Average diameter D 0.2 < D < 0.5 mm
for N = 4 , D > 0.5 for N = 1
Rainbow color or newton ring.
Black lines
Bubbles in
polarizer
Color
uniformity
Glass
Scratches
Contrast
ratio
Response
time
Viewing
angle
Class of
Defects
Major
Major
Minor
Acceptable level
(%)
0.65
1.5
2.5
Minor
2.5
Minor
2.5
Minor
2.5
Obvious visible damage.
Minor
2.5
See note 1
Minor
2.5
See note 2
Minor
2.5
See note 3
Minor
2.5
ZONE A active area
ZONE B viewing area
Date : 2006/9/12
AMPIRE CO., LTD.
15
12.6 RELIABILITY
Test Conditions
Test Item
Normal Temp. type
Extended Temp. type
High Temperature Operation
50±3°C , t=96 hrs
70±3°C , t=96 hrs
Low Temperature Operation
0±3°C , t=96 hrs
-20±3°C , t=96 hrs
High Temperature Storage
Low Temperature Storage
Thermal Shock Test
Humidity Test
Note
70±3°C , t=96 hrs
80±3°C , t=96 hrs
1,2
-20±3°C , t=96 hrs
-30±3°C , t=96 hrs
1,2
-20°C ~ 25°C ~ 70°C
-30°C ~ 25°C ~ 80°C
30 m in. 5 min. 30 min. 30 min. 5 min. 30 min. 1,2
( 1 cycle )
( 1 cycle )
Total 5 cycle
Total 5 cycle
40 °C, Humidity 90%, 96 hrs
1,2
Sweep frequency : 10 ~ 55 ~ 10 Hz/1min
Amplitude : 0.75mm
Vibration Test (Packing)
2
Test direction : X.Y.Z/3 axis
Duration : 30min/each axis
Note 1 : Condensation of water is not permitted on the module.
Note 2 : The module should be inspected after 1 hour storage in normal conditions
(15-35°C , 45-65%RH).
Definitions of life end point :
l Current drain should be smaller than the specific value.
l Function of the module should be maintained.
l Appearance and display quality should not have degraded noticeably.
l Contrast ratio should be greater than 50% of the initial value.
Date : 2006/9/12
AMPIRE CO., LTD.
16
13 HANDLING PRECAUTIONS
(1) A LCD module is a fragile item and should not be subjected to strong mechanical shocks.
(2) Avoid applying pressure to the module surface. This will distort the glass and cause a
change in color.
(3) Under no circumstances should the position of the bezel tabs or their shape be modified.
(4) Do not modify the display PCB in either shape or positioning of components.
(5) Do not modify or move location of the zebra or heat seal connectors.
(6) The device should only be soldered to during interfacing. Modification to other areas of
the board should not be carried out.
(7) In the event of LCD breakage and resultant leakage of fluid do not inhale, ingest or make
contact with the skin. If contact is made rinse immediately.
(8) When cleaning the module use a soft damp cloth with a mild solvent, such as Isopropyl or
Ethyl alcohol. The use of water, ketone or aromatic is not permitted.
(9) Prior to initial power up input signals should not be applied.
(10) Protect the module against static electricity and observe appropriate anti-static
precautions.
Date : 2006/9/12
AMPIRE CO., LTD.
17
晶 采 光 電 科技
14 OUTLINE DIMENSION
Date : 2006/9/12
AMPIRE CO., LTD.
18