SPECIFICATIONS FOR LCD MODULE

A MP I R E
SPECIFICATIONS FOR
LCD MODULE
CUSTOMER
CUSTOMER PART NO.
AMPIRE PART NO.
AF-240160EFIQW
APPROVED BY
DATE
þ Approved For Specifications
o Approved For Specifications & Sample
APPROVED BY
CHECKED BY
Date : 2005/9/5
AMPIRE CO., LTD.
ORGANIZED BY
1
RECORD OF REVISION
Revision Date
Contents
2005/1/21
New Release
2005/5/12
Modify White LED back- light characteristics
2005/9/5
Modify the module electronic characteristics
Date : 2005/9/5
Editor
Rosaline
AMPIRE CO., LTD.
Tony
Lorry
2
1 FEATURES
(1) Display format : 240×160 dots, 1/160 duty, 1/13 bias.
(2) Construction : LCD panel, Edge LED White backlight and COF technology.
(3) Display type : FSTN, Transflective, Positive , 6 o’clock view.
(4) Controller : “ULTRACHIP” UC1611
(5) Interface for 8080 or 6800 series family MPU, select by BM0, BM1 setting.
2 MECHANICAL DATA
Parameter
Stand Value
Unit
Dot size
0.23(W) × 0.23(H)
mm
Dot pitch
0.24(W) × 0.24(H)
mm
Active area
57.59(W) × 38.39(H)
mm
Viewing area
63.0(W) × 42.5(H)
mm
Module size
81.0(W) × 115.5(H) × 6.5Max.(T)
mm
3 ABSOLUTE MAXIMUM RATINGS
Parameter
Symbol
Min
Max
Unit
Logic Circuit Supply Voltage
VDD-VSS
-0.3
+4.0
V
LCD Driving Voltage
VLCD
-4
+18.0
V
Input Voltage
VI
-0.3
VDD+0.3
V
Operating Temp.
TOP
0
50
°C
Storage Temp.
TSTG
-20
70
°C
Date : 2005/9/5
AMPIRE CO., LTD.
3
4 ELECTRO-OPTICAL CHARACTERISTICS
Parameter
Symbol
Condition Min
Typ
Max
----- Electronic Characteristics -----
Unit
Logic Circuit
Supply Voltage
VDD-VSS
--
2.4
2.8
3.3
V
LCD Driving
Voltage
(FSTN )
VLCD
-20 °C
--
--
--
V
0 °C
--
--
--
25 °C
--
14.5*
--
50 °C
--
--
--
70 °C
--
--
--
Input Voltage
VIH
VIL
---
0.8VDD
-0
---
VDD
0.2 VDD
V
V
Logic Supply
Current
IDD
VDD=2.8V
--
0.9
1.2
mA
Note
* The LCD
driving should be
decided by real
design.
----- Optical Characteristics ( FSTN ) ----Contrast
CR
25°C
--
5
--
Note 1
Rise Time
tr
25°C
--
200
--
ms
Fall Time
tf
25°C
--
200
--
ms
Viewing Angle
Range
θf
25°C &
--
40
--
θb
CR≥2
--
35
--
θl
--
35
--
θr
--
35
--
Note 2
Note 3
Deg.
Frame Frequency
fF
-70
-Hz
25°C
----- White LED Back-light Characteristics -----
Parameter
Symbol
Condition
Min
Typ
Max
Unit
Note
Forward Voltage
VF
IF=60mA
--
3.2
3.5
V
Supply Voltage
between A&K
Note 5
Forward Current
IF
VF=3.3V
IF=60mA
---
60
20
80
--
mA
Note 4
Note 4
IF=60mA
IF=60mA
0.28
0.29
0.31
0.32
0.34
0.35
LCM Luminous
intensity
LED C.I.E
X
Y
cd/m2
Note 6
(NOTE 4): Luminous intensity is decided by forward current of White LED.
(NOTE 5): White LEDs are with voltage tolerance
(NOTE 6): White LEDs are with color tolerance
Date : 2005/9/5
AMPIRE CO., LTD.
4
* LED Dice number = 4
A
K
(NOTE 1) Contrast ratio :
CR = (Brightness in OFF state) / (Brightness in ON state)
( NOTE 2 ) Response time :
(NOTE 3) Viewing angle
Date : 2005/9/5
AMPIRE CO., LTD.
5
Date : 2005/9/5
AMPIRE CO., LTD.
6
5 BLOCK DIAGRAM & POWER SUPPLY
R1
R3
R2
R4
DOT 1
. . . .
. . . .
240 x 160
Dots
R159
R160
Seg1
R2
Seg240
C1
C240
UC1611
R160
R1
R159
Passive
Component
1
42
Default Setting:
Symbol
H/L
VCM
OPEN
VS1
OPEN
VS0
PUMP_DN
OPEN
Leave that pin “open” in single LCM situation.
OPEN
DISP_ON
OPEN
SCLK
SM
Description
OPEN
L
Master mode or default in other situation
Date : 2005/9/5
AMPIRE CO., LTD.
7
6 INTERFACE
No.
Symbol
Function
1
NC
2
VDD
Power supply for logic and other analog circuits.
3
VSS
Ground (0V)
4
BM0
5
BM1
Bus modes :
BM[1:0]
6
WR1
Bus Type : 8080 mode “/RD” ; 68mode “E”
7
WR0
Bus Type : 8080 mode “/WR” ; 68 mode “R/W”
8
CD
No Connection
“HL” : 8 bit 8080
“LL” : 4 bit 8080
“HH” : 8 bit 6800
“LH” : 4 bit 6800
Select Control data or Display data for read/write operation.
(“H”: Display data, “L”: control data)
9
CS1
Chip Select. Chip is selected when CS1=”H”. When the chip is
not selected, D[7:0] will be high impedance.
10
RST
When RST=”L”, all control register are re-initialized by their
default state and/or by their pin configurations if applicable.
11
D0
12
D1
13
D2
14
D3
15
D4
16
D5
17
D6
18
D7
19
VSS
Ground (0V)
20
NC
No Connection
4 bits Data Bus for 8080 or 6800
series
8 bits Data Bus for 8080 or
6800 series
Date : 2005/9/5
AMPIRE CO., LTD.
8
7 INSTRUCTION SET
Date : 2005/9/5
AMPIRE CO., LTD.
9
DATA FORMAT :
Date : 2005/9/5
AMPIRE CO., LTD.
10
CONTROL REGISTERS :
Date : 2005/9/5
AMPIRE CO., LTD.
11
Date : 2005/9/5
AMPIRE CO., LTD.
12
8 TIMING CHARACTERISTICS
8080-SYSTEM
Date : 2005/9/5
AMPIRE CO., LTD.
13
6800-SYSTEM
Date : 2005/9/5
AMPIRE CO., LTD.
14
POWER ON/OFF SEQUENCE :
Power-ON Sequence :
UC1611 power-up sequence is simplified by built-in “Power Ready” flags and by the
automatic invocation of System-Reset command after Power-ON-Reset. System
programmer are only commands to UC1611. No additional commands or waits are
required between enabling of the charge pump, turning on the display drivers, writing to
RAM or any other commands.
Power-OFF Sequence :
To prevent the charge stored in capacitors CBX+, CB X-, and CLCD from damaging the LCD
when VDD is switched off, use Reset mode to enable the built-in charge draining circuit
to discharge these external capacitors.
Reference Power-ON sequence
Date : 2005/9/5
Reference Power-OFF sequence
AMPIRE CO., LTD.
15
9 QUALITY AND RELIABILITY
9.1
TEST CONDITIONS
Tests should be conducted under the following conditions :
Ambient temperature : 25 ± 5°C
Humidity
: 60 ± 25% RH.
9.2
SAMPLING PLAN
Sampling method shall be in accordance with MIL-STD-105E , level II, normal
single sampling plan .
9.3 ACCEPTABLE QUALITY LEVEL
A major defect is defined as one that could cause failure to or materially reduce the
usability of the unit for its intended purpose. A minor defect is one that does not materially
reduce the usability of the unit for its intended purpose or is an infringement from established
standards and has no significant bearing on its effective use or operation.
9.4 APPEARANCE
An appearance test should be conducted by human sight at approximately 30 cm
distance from the LCD module under fluorescent light. The inspection area of LCD panel
shall be within the range of following limits.
Date : 2005/9/5
AMPIRE CO., LTD.
16
9.5
INSPECTION QUALITY CRITERIA
Item
Description of defects
Function
Dimension
Black spots
Short circuit or Pattern cut
Deviation from drawings
Ave . dia . D
area A
area B
Disregard
D≤0.2
3
4
0.2<D≤0.3
2
3
0.3<D≤0.4
0.4<D
0
1
Width W, Length L
A
B
disregard
W≤0.03
3
4
0.03<W≤0.05
1
1
0.05<W≤0.07 , L≤3.0
See line criteria
Average diameter D 0.2 < D < 0.5 mm
for N = 4 , D > 0.5 for N = 1
Rainbow color or Newton ring.
Black lines
Bubbles in
polarizer
Color
uniformity
Glass
Scratches
Contrast
ratio
Response
time
Viewing
angle
Class of
Defects
Major
Major
Minor
Acceptable level
(%)
0.65
1.5
2.5
Minor
2.5
Minor
2.5
Minor
2.5
Obvious visible damage.
Minor
2.5
See note 1
Minor
2.5
See note 2
Minor
2.5
See note 3
Minor
2.5
Zone A active area
Zone B viewing area
Date : 2005/9/5
AMPIRE CO., LTD.
17
9.6 RELIABILITY
Test Conditions
Test Item
Extended Temp. type
High Temperature Operation
70±3°C , t=96 hrs
Low Temperature Operation
-20±3°C , t=96 hrs
High Temperature Storage
Low Temperature Storage
Thermal Shock Test
Humidity Test
Note
80±3°C , t=96 hrs
1,2
-30±3°C , t=96 hrs
1,2
-20°C ~ 25°C ~ 70°C
30 m in. 5 min. 30 min. ( 1 cycle ) 1,2
Total 5 cycle
40 °C, Humidity 90%, 96 hrs
1,2
Sweep frequency : 10 ~ 55 ~ 10 Hz/1min
Amplitude : 0.75mm
Vibration Test (Packing)
2
Test direction : X.Y.Z/3 axis
Duration : 30min/each axis
Note 1 : Condensation of water is not permitted on the module.
Note 2 : The module should be inspected after 1 hour storage in normal conditions
(15-35°C , 45-65%RH).
Definitions of life end point :
l Current drain should be smaller than the specific value.
l Function of the module should be maintained.
l Appearance and display quality should not have degraded noticeably.
l Contrast ratio should be greater than 50% of the initial value.
Date : 2005/9/5
AMPIRE CO., LTD.
18
10 HANDLING PRECAUTIONS
(1) A LCD module is a fragile item and should not be subjected to strong mechanical shocks.
(2) Avoid applying pressure to the module surface. This will distort the glass and cause a
change in color.
(3) Under no circumstances should the position of the bezel tabs or their shape be modified.
(4) Do not modify the displa y PCB in either shape or positioning of components.
(5) Do not modify or move location of the zebra or heat seal connectors.
(6) The device should only be soldered to during interfacing. Modification to other areas of
the board should not be carried out.
(7) In the event of LCD breakage and resultant leakage of fluid do not inhale, ingest or make
contact with the skin. If contact is made rinse immediately.
(8) When cleaning the module use a soft damp cloth with a mild solvent, such as Isopropyl or
Ethyl alcohol. The use of water, ketone or aromatic is not permitted.
(9) Prior to initial power up input signals should not be applied.
(10) Protect the module against static electricity and observe appropriate anti-static
precautions.
Date : 2005/9/5
AMPIRE CO., LTD.
19
晶采 光 電 科技
11 OUTLINE DIMENSION
Date : 2005/9/5
AMPIRE CO., LTD.
20