Preliminary The contents of this document are confidential and must not be disclosed wholly or in part to any third part without the prior written consent of AMPIRE CO., LTD SPECIFICATIONS FOR LCD MODULE CUSTOMER CUSTOMER PART NO. AMPIRE PART NO. APPROVED AM-800480STMQW-A0 BY DATE ; Approved For Specifications Approved For Specifications & Sample AMPIRE CO., LTD. 2F., No.88, Sec. 1, Sintai 5th Rd., Sijhih City, Taipei County 221, Taiwan (R.O.C.)台北縣汐止市新台五路一段 88 號 2 樓(東方科學園區 D 棟) TEL:886-2-26967269 , FAX:886-2-26967196 or 26967270 APPROVED BY Date : 2009/09/25 CHECKED BY AMPIRE CO., LTD. ORGANIZED BY 1 Preliminary The contents of this document are confidential and must not be disclosed wholly or in part to any third part without the prior written consent of AMPIRE CO., LTD RECORD Revision Date Page 2009/09/03 -- 2009/09/09 -- 2009/09/25 OF REVISION Contents Editor New Release Emil Issued the official part No. to AM-800480STMQW-A0. Emil 21,22 Update the Mechanical drawing. Emil 2009/09/25 7 Update the optical specifications. Emil 2009/09/25 13 Addition the TTL RGB interface timing. Emil Date : 2009/09/25 AMPIRE CO., LTD. 2 Preliminary The contents of this document are confidential and must not be disclosed wholly or in part to any third part without the prior written consent of AMPIRE CO., LTD 1. Features 7 inch module is a color active matrix thin film transistor (TFT) liquid crystal display (LCD) that uses amorphous silicon TFT as a switching device. This model is composed of a TFT LCD panel, a driving circuit and a back light system. This TFT LCD has a 7.0 (16:9) inch diagonally measured active display area with WVGA (800 horizontal by 480 vertical pixel) resolution. (1) Construction: 7” a-Si TFT active matrix, White LED Backlight. (2) Resolution (pixel): 800(R.G.B) X 480 (3) Number of the Colors : 262K colors ( R , G , B 6 bit digital each) (4) LCD type : Transmissive , normally White (5) Power Supply Voltage: 3.0V for logic voltage. (7) Viewing Direction: 6 O’clock ( The direction it’s hard to be discolored ) (8) Interface : LVDS interface 2. PHYSICAL SPECIFICATIONS Item LCD size Outline Dimension (Include connecter) Specifications unit 7 inch (Diagonal) 165.0 x 104.44 x 7.96 (typ.) mm Number of Pixel 800 RGB (H) x 480 (V) pixels Pixel pitch 0.1905 (H) x 0.1905 (V) mm Pixel arrangement Display mode Surface treatment Weight Back-light Power consumption (without B/L system) Date : 2009/09/25 RGB Vertical stripe Normally white Antiglare, Hard-Coating (3H) with EWV film 135 (typ.) g Single LED (Side-Light type) 2.3. (max.) AMPIRE CO., LTD. W 3 Preliminary The contents of this document are confidential and must not be disclosed wholly or in part to any third part without the prior written consent of AMPIRE CO., LTD 3. ABSOLUTE MAX. RATINGS 3-1 Electrical Absolute Rating 3-1-1 TFT LCD Module Item Symbol Power voltage VCC Voltage range at any terminal 3-2 Values UNIT Note 4.0 V GND=0V -0.5 VCC+0.3 V Min. Max. -0.5 Environment Absolute Rating Item Symbol Min. Max. Unit Operating Temperature Topa -20 70 ℃ Storage Temperature Tstg -30 80 ℃ Date : 2009/09/25 AMPIRE CO., LTD. Note 4 Preliminary The contents of this document are confidential and must not be disclosed wholly or in part to any third part without the prior written consent of AMPIRE CO., LTD 4. ELECTRICAL CHARACTERISTICS 4-1 TFT LCD Module Date : 2009/09/25 AMPIRE CO., LTD. 5 Preliminary The contents of this document are confidential and must not be disclosed wholly or in part to any third part without the prior written consent of AMPIRE CO., LTD 4-2 Backlight Unit Item Symbol Min. Typ. Max. Unit Note ILED =270mA Ta=25℃ LED voltage VAK -- 9.9 -- V LED current ILED -- 160 -- mA Ta=25℃ -- 145 -- mA Ta=60℃ LED Life Time - 10K 20K -- Hour Note (2) Note (1) The constant current source is needed for white LED back-light driving. When LCM is operated over 60 deg.C ambient temperature, the ILED of the LED back-light should be adjusted to 135mA max Allowable Forward Current IF (mA) Note (2) Brightness to be decreased to 50% of the initial value. 180 160 140 120 -20 -10 0 10 20 30 40 50 60 70 LED Light Bar Circuit Date : 2009/09/25 AMPIRE CO., LTD. 6 Preliminary The contents of this document are confidential and must not be disclosed wholly or in part to any third part without the prior written consent of AMPIRE CO., LTD 5. Optical Specifications 5-1 Optical specification Item Viewing Angle Symbol Min. Typ. Max. Unit Note 50 60 -- 60 70 -- deg. (1)(2)(3) 60 70 -- 60 70 -- 250 400 -- -- (1)(3) Tr -- 5 10 ms (1)(4) Tf -- 11 16 ms (1)(4) Wx 0.249 0.299 0.349 Wy 0.278 0.328 0.378 0.522 0.572 0.622 0.308 0.358 0.408 Gx 0..291 0.341 0.391 -- (1) Gy 0.534 0.584 0.634 Bx 0.082 0.132 0.182 By 0.083 0.133 0.183 Front θf Back θb Left θl Right θr Contrast ratio CR Response Time White Red Color chromaticity Green Blue Luminance Luminance Uniformity Rx Ry Condition CR≧10 Θ=Φ=0° Θ=Φ=0° L Θ=Φ=0° 300 350 -- cd/m2 (1)(5) ΔL Θ=Φ=0° 70 -- -- % (1)(5)(6) Note 1: Ta=25°C. To be measured on the center area of panel after 10 minutes operation. Note 2: Definition of Viewing Angle Date : 2009/09/25 AMPIRE CO., LTD. 7 Preliminary The contents of this document are confidential and must not be disclosed wholly or in part to any third part without the prior written consent of AMPIRE CO., LTD Note 3: Definition of contrast ratio: Contrast ratio is calculated with the following formula. Contrast ratio(CR)= Photo detector output when LCD is at ”White” state Photo detector Output when LCD is at “Black” state Note 4: Definition of response time: The output signals of photo detector are measured when the input signals are changed from “black“ to “white”(falling time) and from ”white” to “black” (rising time) respectively. The response time is defined as the time interval between the 10% and 90% of amplitudes. Refer to figure as below. Note 5 : Luminance is measured at point 5 of the display. Note 6 : Definition of Luminance Uniformity ΔL = [ L(min.) of 9 points / L(max.) of 9 points] X 100% Date : 2009/09/25 AMPIRE CO., LTD. 8 Preliminary The contents of this document are confidential and must not be disclosed wholly or in part to any third part without the prior written consent of AMPIRE CO., LTD 6. Block Diagram 800 (RGB) x 480 TFT LCD Panel TFT LCD Panel Unit Power Unit and LVDS Unit IN0+, IN0-, IN1+, IN1-, IN2+, IN2- Date : 2009/09/25 CLK+, CLK- VCC GND AMPIRE CO., LTD. LED A LED K 9 Preliminary The contents of this document are confidential and must not be disclosed wholly or in part to any third part without the prior written consent of AMPIRE CO., LTD 7. INTERFACE Pin No. Symbol Function 1 VDD POWER SUPPLY:3.3V 2 VDD POWER SUPPLY:3.3V 3 Gnd Power Ground 4 Gnd Power Ground 5 IN0- Transmission Data of Pixels 6 IN0+ Transmission Data of Pixels 7 Gnd Power Ground 8 IN1- Transmission Data of Pixels 1 9 IN1+ Transmission Data of Pixels 1 10 Gnd Power Ground 11 IN2- Transmission Data of Pixels 2 12 IN2+ Transmission Data of Pixels 2 13 Gnd Power Ground 14 CLK- Sampling Clock 15 CLK+ Sampling Clock 16 Gnd Power Ground 17 LEDADJ 18 VLED 19 Gnd Power Ground 20 Gnd Power Ground LED Dimming Pin; (Keep this pin NC in this model). LED Driver IC Power Supply 3.3V~5.0V; (Keep this pin NC in this model). Note: The LCM AM-800480STMQW-A0 does not build-in LED driver circuit. please keep pin 17 and 18 NC. Date : 2009/09/25 AMPIRE CO., LTD. 10 Preliminary The contents of this document are confidential and must not be disclosed wholly or in part to any third part without the prior written consent of AMPIRE CO., LTD 8. INPUT SIGNAL : 8-1 LVDS Signal Date : 2009/09/25 AMPIRE CO., LTD. 11 Preliminary The contents of this document are confidential and must not be disclosed wholly or in part to any third part without the prior written consent of AMPIRE CO., LTD Date : 2009/09/25 AMPIRE CO., LTD. 12 Preliminary The contents of this document are confidential and must not be disclosed wholly or in part to any third part without the prior written consent of AMPIRE CO., LTD 8-2 TTL RGB Interface Timing Date : 2009/09/25 AMPIRE CO., LTD. 13 Preliminary The contents of this document are confidential and must not be disclosed wholly or in part to any third part without the prior written consent of AMPIRE CO., LTD 9. DISPLAYED COLOR AND INPUT DATA Basic Color Color & Gray Scale R5 R4 R3 R2 R1 R0 G5 G4 G3 G2 G1 G0 B5 B4 B3 B2 B1 B0 Black 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Red(63) 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 Green(63) 0 0 0 0 0 0 1 1 1 1 1 1 0 0 0 0 0 0 Blue(63) 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 Cyan 0 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 Magenta 1 1 1 1 1 1 0 0 0 0 0 0 1 1 1 1 1 1 Yellow 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 0 White 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Black 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Red(1) 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 Red(2) 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 : : : : : : : : : : : : : : : : : : : Red(31) 0 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 : : : : : : : : : : : : : : : : : : : Red(62) 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 Red(63) 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 Black 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Green(1) 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 Green(2) 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 : : : : : : : : : : : : : : : : : : : Green(31) 0 0 0 0 0 0 0 1 1 1 1 0 0 0 0 0 0 0 : : : : : : : : : : : : : : : : : : : Green(62) 0 0 0 0 0 0 1 1 1 1 1 0 0 0 0 0 0 0 Green(63) 0 0 0 0 0 0 1 1 1 1 1 1 0 0 0 0 0 0 Black 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Blue(1) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 Blue(2) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 : : : : : : : : : : : : : : : : : : : Blue(31) 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 : : : : : : : : : : : : : : : : : : : Blue(62) 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 0 Blue(63) 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 DATA SIGNAL Red Green Blue Date : 2009/09/25 AMPIRE CO., LTD. 14 Preliminary The contents of this document are confidential and must not be disclosed wholly or in part to any third part without the prior written consent of AMPIRE CO., LTD 10. RELIABILITY TEST CONDITIONS 10.1. Test Conditions Tests should be conducted under the following conditions : Ambient temperature : 25 ± 5°C Humidity : 60 ± 25% RH. 10.2. Sampling Plan Sampling method shall be in accordance with MIL-STD-105E , level II, normal single sampling plan . 10.3. Acceptable Quality Level A major defect is defined as one that could cause failure to or materially reduce the usability of the unit for its intended purpose. A minor defect is one that does not materially reduce the usability of the unit for its intended purpose or is an infringement from established standards and has no significant bearing on its effective use or operation. 10.4. Appearance An appearance test should be conducted by human sight at approximately 30 cm distance from the LCD module under florescent light. The inspection area of LCD panel shall be within the range of following limits. 10.5. Incoming Inspection Standard Date : 2009/09/25 AMPIRE CO., LTD. 15 Preliminary The contents of this document are confidential and must not be disclosed wholly or in part to any third part without the prior written consent of AMPIRE CO., LTD Defect Type Limit φ<0.15mm Spot Visual Defect Fiber Internal Polarizer Bubble Mura Bright Dot 0.15mm≦φ≦0.5mm 0.5mm<φ 0.1mm<W≦0.5mm, L≦1.5mm 1.0mm<W, 1.5mm<L φ<0.15mm Note Ignore N≦4 N=0 N≦4 N=0 Ignore 0.15mm≦φ≦0.5mm N≦4 0.5mm<φ N=0 It’ OK if mura is slight visible through 6%ND filter A Grade B Grade C O C O Total Total Area Area Area Area N≦0 N≦2 N≦2 N≦2 N≦3 N≦5 (1) (1) (3) (2) N≦2 N≦4 N≦4 N≦3 N≦5 N≦8 Dark Dot Electrical Defect (1) N≦4 Total Dot Two Adjacent Dot N≦0 N≦5 N≦6 N≦8 (2) N≦1 N≦1 N≦1 N≦1 N≦1 pair pair pair pair pair (4) Three or More Adjacent Dot Not Allowed Line Defect Not Allowed (1) One pixel consists of 3 sub-pixels, including R,G, and B dot.(Sub-pixel = Dot) (2) LITTLE BRIGHT DOT acceptable under 6% ND-Filter [Note1] W : Width[mm], L : Length[mm], N : Number, φ: Average Diameter [Note2] Bright dot is defined through 6% transmission ND Filter as following. Date : 2009/09/25 AMPIRE CO., LTD. 16 Preliminary The contents of this document are confidential and must not be disclosed wholly or in part to any third part without the prior written consent of AMPIRE CO., LTD [Note3] C Area: Center of display area C Area: Outer of display area [Note4] Judge defect dot and adjacent dot as following. Allow below (as A, B, C and D status) adjacent defect dots, including bright and dart adjacent dot. And they will be counted 2 defect dots in total quantity. (1) The defects that are not defined above and considered to be problem shall be reviewed and discussed by both parties. (2) Defects on the Black Matrix, out of Display area, are not considered as a defect or counted. 10.6. Reliability Test Date : 2009/09/25 AMPIRE CO., LTD. 17 Preliminary The contents of this document are confidential and must not be disclosed wholly or in part to any third part without the prior written consent of AMPIRE CO., LTD Test Item High Temperature Operation Low Temperature Operation High Temperature Storage Low Temperature Storage Thermal Shock Test Humidity Test Test Conditions Note 70±3°C , t=96 hrs -20±3°C , t=96 hrs 80±3°C , t=96 hrs -30±3°C , t=96 hrs -20°C ~ 70°C 30 m in. ~ 30 min. ( 1 cycle ) Total 100cycle 60 °C, Humidity 90%, 240 hrs 1,2 1,2 1,2 1,2 Sweep frequency : 10 ~ 500 ~ 10 Hz/1min Amplitude : 0.75mm Vibration Test (Packing) 2 Test direction : X.Y.Z/3 axis Duration : 30min/each axis Note 1 : Condensation of water is not permitted on the module. Note 2 : The module should be inspected after 1 hour storage in normal conditions (15-35°C , 45-65%RH). Definitions of life end point : z z z z Current drain should be smaller than the specific value. Function of the module should be maintained. Appearance and display quality should not have degraded noticeably. Contrast ratio should be greater than 50% of the initial value. Date : 2009/09/25 AMPIRE CO., LTD. 18 Preliminary The contents of this document are confidential and must not be disclosed wholly or in part to any third part without the prior written consent of AMPIRE CO., LTD 11. USE PRECAUTIONS 11.1. Handling precautions 1) The polarizing plate may break easily so be careful when handling it. Do not touch, press or rub it with a hard-material tool like tweezers. 2) Do not touch the polarizing plate surface with bare hands so as not to make it dirty. If the surface or other related part of the polarizing plate is dirty, soak a soft cotton cloth or chamois leather in benzine and wipe off with it. Do not use chemical liquids such as acetone, toluene and isopropyl alcohol. Failure to do so may bring chemical reaction phenomena and deteriorations. 3) Remove any spit or water immediately. If it is left for hours, the suffered part may deform or decolorize. 4) If the LCD element breaks and any LC stuff leaks, do not suck or lick it. Also if LC stuff is stuck on your skin or clothing, wash thoroughly with soap and water immediately. 11.2. Installing precautions 1) The PCB has many ICs that may be damaged easily by static electricity. To prevent breaking by static electricity from the human body and clothing, earth the human body properly using the high resistance and discharge static electricity during the operation. In this case, however, the resistance value should be approx. 1MΩ and the resistance should be placed near the human body rather than the ground surface. When the indoor space is dry, static electricity may occur easily so be careful. We recommend the indoor space should be kept with humidity of 60% or more. When a soldering iron or other similar tool is used for assembly, be sure to earth it. 2) When installing the module and ICs, do not bend or twist them. Failure to do so may crack LC element and cause circuit failure. 3) To protect LC element, especially polarizing plate, use a transparent protective plate (e.g., acrylic plate, glass etc) for the product case. 4) Do not use an adhesive like a both-side adhesive tape to make LCD surface (polarizing plate) and product case stick together. Failure to do so may cause the polarizing plate to peel off. Date : 2009/09/25 AMPIRE CO., LTD. 19 Preliminary The contents of this document are confidential and must not be disclosed wholly or in part to any third part without the prior written consent of AMPIRE CO., LTD 11.3. Storage precautions 1) Avoid a high temperature and humidity area. Keep the temperature between 0°C and 35°C and also the humidity under 60%. 2) Choose the dark spaces where the product is not exposed to direct sunlight or fluorescent light. 3) Store the products as they are put in the boxes provided from us or in the same conditions as we recommend. 11.4. Operating precautions 1) Do not boost the applied drive voltage abnormally. Failure to do so may break ICs. When applying power voltage, check the electrical features beforehand and be careful. Always turn off the power to the LC module controller before removing or inserting the LC module input connector. If the input connector is removed or inserted while the power is turned on, the LC module internal circuit may break. 2) The display response may be late if the operating temperature is under the normal standard, and the display may be out of order if it is above the normal standard. But this is not a failure; this will be restored if it is within the normal standard. 3) The LCD contrast varies depending on the visual angle, ambient temperature, power voltage etc. Obtain the optimum contrast by adjusting the LC dive voltage. 4) When carrying out the test, do not take the module out of the low-temperature space suddenly. Failure to do so will cause the module condensing, leading to malfunctions. 5) Make certain that each signal noise level is within the standard (L level: 0.2Vdd or less and H level: 0.8Vdd or more) even if the module has functioned properly. If it is beyond the standard, the module may often malfunction. In addition, always connect the module when making noise level measurements. 6) The CMOS ICs are incorporated in the module and the pull-up and pull-down function is not adopted for the input so avoid putting the input signal open while the power is ON. 7) The characteristic of the semiconductor element changes when it is exposed to light emissions, therefore ICs on the LCD may malfunction if they receive light emissions. To prevent these malfunctions, design and assemble ICs so that they are shielded from light emissions. 8) Crosstalk occurs because of characteristics of the LCD. In general, crosstalk occurs when the regularized display is maintained. Also, crosstalk is affected by the LC drive Date : 2009/09/25 AMPIRE CO., LTD. 20 Preliminary The contents of this document are confidential and must not be disclosed wholly or in part to any third part without the prior written consent of AMPIRE CO., LTD voltage. Design the contents of the display, considering crosstalk. 11.5. Other 1) Do not disassemble or take the LC module into pieces. The LC modules once disassembled or taken into pieces are not the guarantee articles. 2) The residual image may exist if the same display pattern is shown for hours. This residual image, however, disappears when another display pattern is shown or the drive is interrupted and left for a while. But this is not a problem on reliability. 3) AMIPRE will provide one year warrantee for all products and three months warrantee for all repairing products. Date : 2009/09/25 AMPIRE CO., LTD. 21 Preliminary The contents of this document are confidential and must not be disclosed wholly or in part to any third part without the prior written consent of AMPIRE CO., LTD 12. OUTLINE DIMENSION Date : 2009/09/25 AMPIRE CO., LTD. 22 Preliminary The contents of this document are confidential and must not be disclosed wholly or in part to any third part without the prior written consent of AMPIRE CO., LTD Date : 2009/09/25 AMPIRE CO., LTD. 23