SPECIFICATIONS FOR LCD MODULE

SPECIFICATIONS FOR
LCD MODULE
CUSTOMER
CUSTOMER PART NO.
AMPIRE PART NO.
APPROVED
AM-800600LTNQW-D0H
BY
DATE
†Approved For Specifications
; Approved For Specifications & Sample
AMPIRE CO., LTD.
2F., No.88, Sec. 1, Sintai 5th Rd., Sijhih City, Taipei County 221,
Taiwan (R.O.C.)台北縣汐止市新台五路一段 88 號 2 樓(東方科學園區 D 棟)
TEL:886-2-26967269 , FAX:886-2-26967196 or 26967270
APPROVED BY
Date : 2009/11/19
CHECKED BY
ORGANIZED BY
AMPIRE CO., LTD.
1
RECORD
Revision Date Page
2009/09/11
2009/09/16
2009/09/17
2009/09/18
2009/09/18
2009/10/07
2009/11/17
8
17,18
19
-
2009/11/19
Date : 2009/11/19
10
OF
REVISION
Contents
Editor
New Release
Modify the Optical and electrical characteristics.
Modify the section of interface.
Update the mechanical drawing (front cover of the drawing).
Addition a packing drawing.
Issued the official part No. to AM800600LTNQW-D0H.
Remark the revising records:
Replace the connecter:
Emil
Emil
Emil
Emil
Emil
Emil
Emil
CN1
HRS DF19K-20P 1H
CN2
JST SM04B-SRSS-TB (LF) (SN)
Add new PCB (800600L-D0 Rev. A)
Add Date Code Label
AMPIRE CO., LTD.
Kokai
2
1. INSTRUCTION
Ampire 10.4” Display Module is a color active matrix TFT-LCD that uses amorphous
silicon TFT as a switching device. This model is composed of a TFT-LCD panel and LED
Backlight. This TFT-LCD has a high resolution (800(R.G.B) X 600) and can display up to
262,144 colors.
1.1 Features
(1) Construction: a-Si TFT-LCD with driving system, White LED Backlight and LED Driver IC.
(2) LCD type : Transmissive , Normally White
(3) Number of the Colors : 262K colors (R,G,B 6 bit digital each)
(4) LVDS Interface.
(5) LCD Power Supply Voltage : 3.3V
(6) Build-in LED Driver IC (VLED=3.3V~5V).
2. PHYSICAL SPECIFICATIONS
Item
Specifications
unit
Display resolution(dot)
800RGB (W) x 600(H)
dots
Active area
211.2 (W) x 158.4(H)
mm
Pixel pitch
264 (W) x 264 (H)
um
Color configuration
R.G.B -stripe
Overall dimension
236.0(W)x176.9(H)x11.26(D)
mm
Weight
312
g
Brightness
300
cd/m2
Backlight unit
LED
Display color
262,144
Date : 2009/11/19
AMPIRE CO., LTD.
colors
3
3. ABSOLUTE MAXIMUM RATINGS
Item
Symbol
Min.
Max.
Unit
VCC
-0.3
6
V
VLED
-0.3
6
V
Operation
-20
70
℃
Storage
-30
80
℃
Power Voltage
Temperature Range
(1). All of the voltages listed above are with respective to GND =0V
(2). Device is subject to be damaged permanently if stresses beyond those absolute
maximum ratings listed above.
4. OPTICAL CHARACTERISTICS
Item
Symbol
Response Time
Contrast ratio
Typ.
Max.
Unit
Note
-
25
50
ms
(1)
300
400
-
-
(2)(3)
35
45
-
55
65
-
55
65
-
Deg.
(5)
ΘR
55
65
-
L
240
300
-
cd/m2
(3)
ΔL
-
80
-
%
(4)
Rx
Ry
Gx
Gy
Bx
By
Wx
Wy
0.550
0.296
0.283
0.516
0.092
0.065
0.259
0.284
0.600
0.364
0.333
0.566
0.142
0.115
0.309
0.334
0.650
0.396
0.383
0.616
0.192
0.165
0.359
0.384
-
CR
Vertical
Viewing
Angle
Min.
Tr +Tf
Horizontal
Luminance
Luminance Uniformity
Red
Green
Chormaticity
Blue
White
Condition
Θ=Φ=0°
ΘT
ΘB
ΘL
CR≧10
Θ=Φ=0°
NOTE :
● These items are measured by BM-5A(TOPCON) or CA-1000(MINOLTA) in the dark room
(no ambient light) After 5 minutes operation, the optical properties are measured at the center point of
the LCD screen.
Date : 2009/11/19
AMPIRE CO., LTD.
4
(1) Definition of Response Time (White-Black)
(2) Definition of Contrast Ratio
Contrast ratio is calculated with the following formula :
Contrast Ratio(CR)=(White)Luminance of ON ÷ (Black)Luminance of OFF
(3) Definition of Luminance:
Measure the luminance of white state at center point.
(4)Definition of Luminance Uniformity :
Measured Maximum luminance [L(MAX)] and Minimum luminance[L(MIN)] on the 9
points.
Luminance Uniformity is calculated with the following formula:
ΔL =[ L(MIN) / L (MAX) ] X 100%
(5)Definition of Viewing Angle
Date : 2009/11/19
AMPIRE CO., LTD.
5
5. ELECTRICAL CHARACTERISTICS
5.1 TFT LCD Module voltage
ITEM
Power Voltage For LCD
Digital Supply current
Consumption
Logic Input Voltage
SYMBOL
MIN
TYP
MAX
UNIT
VCC
3.0
3.3
3.6
V
IVCC
290
VIH
VCC*0.7
--
VCC
V
VIL
0
--
VCC*0.3
V
5.2 Backlight Driving Circuit
ITEM
SYMBOL
LED Driver
VLED
Power Voltage
LED Current
ILED
LED Life Time(MTBF)
LED Driver
Power Current
Date : 2009/11/19
mA
ILED(VLED=5V)
NOTE
Black Pattern
MIN
TYP
MAX
UNIT
3.3
5
5.5
V
-30K
90
--
---
mA
Hr
Note1
Note2
-
500
--
mA
Ta=25℃
AMPIRE CO., LTD.
NOTE
6
Note 1 : There are 6 Groups LED shown as below , VLEDA-LEDK=19.2V ,Ta=25℃
LED_A
20mA
120mA
90mA
15mA
LED_K
Note2 : Condition: Ta=25℃, continuous lighting
Life time is estimated data.
Definitions of failure:
1. LCM brightness becomes half of the minimum value.
2. LED doesn’t light normally.
5.3
PWM Dimming Control
F=100~200Hz
3.3V
0V
Date : 2009/11/19
AMPIRE CO., LTD.
7
6. INTERFACE
LVDS INTERFACE CN1: HRS DF19K-20P 1H
Pin No.
Symbol
I/O
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
VDD
VDD
GND
GND
IN0IN0+
GND
IN1IN1+
GND
IN2IN2+
GND
CLKCLK+
GND
NC
NC
GND
GND
P
P
P
P
I
I
P
I
I
P
I
I
P
I
I
P
I
P
Description
Note
Power supply for digital circuit (3.3V)
Power supply for digital circuit (3.3V)
Power ground
Power ground
LVDS receiver negative signal channel 0
LVDS receiver positive signal channel 0
Power ground
LVDS receiver negative signal channel 1
LVDS receiver positive signal channel 1
Power ground
LVDS receiver negative signal channel 2
LVDS receiver positive signal channel 2
Power ground
LVDS receiver negative signal clock
LVDS receiver positive signal clock
Power ground
No connection
No connection
Power ground
Adjust the LED brightness by PWM
CN2: JST SM04B-SRSS-TB (LF) (SN)
Pin No.
Symbol
I/O
1
2
3
4
VLED
LED_EN
GND
ADJ
P
I
I
P
Date : 2009/11/19
Description
Note
Voltage for LED circuit (3.3V~5.0V)
LED BLU ON/OFF
Power ground
Adjust the LED brightness by PWM
AMPIRE CO., LTD.
8
7. AC Timing characteristic
7-1 Timing Specification.
Date : 2009/11/19
AMPIRE CO., LTD.
9
7-2 Power ON/OFF Sequence
8. Date Code Label
AM800600L
AMPIRE Part Number: AM800600LTNQW-D0H
TNQW-D0H
46.09
B4588
Date : 2009/11/19
Date code: 09: 2009 year. 46 : 46th week
Production Lot Number : D47609
AMPIRE CO., LTD.
10
8. QUALITY AND RELIABILITY
8.1
TEST CONDITIONS
Tests should be conducted under the following conditions :
Ambient temperature : 25 ± 5°C
Humidity
: 60 ± 25% RH.
8.2
SAMPLING PLAN
Sampling method shall be in accordance with MIL-STD-105E , level II, normal single
sampling plan .
8.3
ACCEPTABLE QUALITY LEVEL
A major defect is defined as one that could cause failure to or materially reduce the
usability of the unit for its intended purpose. A minor defect is one that does not materially
reduce the usability of the unit for its intended purpose or is an infringement from established
standards and has no significant bearing on its effective use or operation.
8.4
APPEARANCE
An appearance test should be conducted by human sight at approximately 30 cm
distance from the LCD module under florescent light. The inspection area of LCD panel shall
be within the range of following limits.
Date : 2009/11/19
AMPIRE CO., LTD.
11
8.5
INCOMING INSPECTION STANDARD FOR
DEFECT TYPE
TFT-LCD PANEL
Note
LIMIT
φ<0.15mm
SPOT
DEFECT
0.15mm≦φ≦0.5mm
FIBER
VISUAL
INTERNAL
POLARIZER
BUBBLE
0.5mm<φ
0.03mm<W≦0.1mm, L≦
5mm
1.0mm<W, 1.5mm<L
φ<0.15mm
0.15mm≦φ≦0.5mm
0.5mm<φ
Note1
N=0
N≦3
N=0
Ignore
N≦2
N=0
Note1
Note1
It’ OK if mura is slight visible through
6%ND filter
Mura
A Grade
BRIGHT DOT
DARK DOT
B Grade
C Area O Area
Total
C Area O Area
Total
Note3
N≦0
N≦2
N≦2
N≦2
N≦3
N≦5
Note2
N≦2
N≦3
N≦3
N≦3
N≦5
N≦8
N≦5
N≦6
N≦8
Note2
N≦1
pair
N≦1
pair
N≦1
pair
Note4
N≦4
TOTAL DOT
ELECTRICAL
DEFECT
Ignore
N≦4
TWO ADJACENT DOT
N≦0
N≦1
pair
N≦1
pair
THREE OR MORE
NOT ALLOWED
ADJACENT DOT
LINE DEFECT
NOT ALLOWED
(1) One pixel consists of 3 sub-pixels, including R,G, and B dot.(Sub-pixel = Dot)
(2) LITTLE BRIGHT DOT ACCEPTABLE UNDER 6 % ND-Filter
[Note1] W : Width[mm], L : Length[mm], N : Number, φ: Average Diameter
[Note2] Bright dot is defined through 6% transmission ND Filter as following.
Date : 2009/11/19
AMPIRE CO., LTD.
12
[Note3]
C Area: Center of display area
C Area: Outer of display area
[Note4]
Judge defect dot and adjacent dot as following. Allow below (as A, B, C and D status)
adjacent defect dots, including bright and dart adjacent dot. And they will be counted 2
defect dots in total quantity.
(1) The defects that are not defined above and considered to be problem shall be reviewed
and discussed by both parties.
(2) Defects on the Black Matrix, out of Display area, are not considered as a defect or counted.
Date : 2009/11/19
AMPIRE CO., LTD.
13
8.6 Reliability Test
Test Item
Test Conditions
High Temperature Operation
70±3°C , t=96 hrs
Low Temperature Operation
-20±3°C , t=96 hrs
High Temperature Storage
80±3°C , t=96 hrs
Low Temperature Storage
Thermal Shock Test
Humidity Test
Note
1,2
-30±3°C , t=96 hrs
-20°C ~ 25°C ~ 70°C
30 m in.
5 min. 30 min. ( 1 cycle )
Total 5 cycle
60 °C, Humidity 90%, 96 hrs
z
z
z
2
Current drain should be smaller than the specific value.
Function of the module should be maintained.
Appearance and display quality should not have degraded noticeably.
Contrast ratio should be greater than 50% of the initial value.
Date : 2009/11/19
AMPIRE CO., LTD.
1,2
1,2
Sweep frequency : 10 ~ 55 ~ 10 Hz/1min
Amplitude : 0.75mm
Vibration Test (Packing)
Test direction : X.Y.Z/3 axis
Duration : 30min/each axis
Note 1 : Condensation of water is not permitted on the module.
Note 2 : The module should be inspected after 1 hour storage in normal conditions
(15-35°C , 45-65%RH).
Definitions of life end point :
z
1,2
14
9. USE PRECAUTIONS
9.1 Handling precautions
1) The polarizing plate may break easily so be careful when handling it. Do not touch, press or
rub it with a hard-material tool like tweezers.
2) Do not touch the polarizing plate surface with bare hands so as not to make it dirty. If the
surface or other related part of the polarizing plate is dirty, soak a soft cotton cloth or
chamois leather in benzine and wipe off with it. Do not use chemical liquids such as
acetone, toluene and isopropyl alcohol. Failure to do so may bring chemical reaction
phenomena and deteriorations.
3) Remove any spit or water immediately. If it is left for hours, the suffered part may deform or
decolorize.
4) If the LCD element breaks and any LC stuff leaks, do not suck or lick it. Also if LC stuff is stuck on
your skin or clothing, wash thoroughly with soap and water immediately.
9.2 Installing precautions
1) The PCB has many ICs that may be damaged easily by static electricity. To prevent
breaking by static electricity from the human body and clothing, earth the human body
properly using the high resistance and discharge static electricity during the operation. In
this case, however, the resistance value should be approx. 1MΩ and the resistance should
be placed near the human body rather than the ground surface. When the indoor space is
dry, static electricity may occur easily so be careful. We recommend the indoor space
should be kept with humidity of 60% or more. When a soldering iron or other similar tool is
used for assembly, be sure to earth it.
2) When installing the module and ICs, do not bend or twist them. Failure to do so may crack
LC element and cause circuit failure.
3) To protect LC element, especially polarizing plate, use a transparent protective plate (e.g.,
acrylic plate, glass etc) for the product case.
4) Do not use an adhesive like a both-side adhesive tape to make LCD surface (polarizing
plate) and product case stick together. Failure to do so may cause the polarizing plate to
peel off.
9.3 Storage precautions
1) Avoid a high temperature and humidity area. Keep the temperature between 0°C and 35°C
and also the humidity under 60%.
2) Choose the dark spaces where the product is not exposed to direct sunlight or fluorescent
light.
3) Store the products as they are put in the boxes provided from us or in the same conditions
as we recommend.
Date : 2009/11/19
AMPIRE CO., LTD.
15
9.4 Operating precautions
1) Do not boost the applied drive voltage abnormally. Failure to do so may break ICs. When
applying power voltage, check the electrical features beforehand and be careful. Always
turn off the power to the LC module controller before removing or inserting the LC module
input connector. If the input connector is removed or inserted while the power is turned on,
the LC module internal circuit may break.
2) The display response may be late if the operating temperature is under the normal
standard, and the display may be out of order if it is above the normal standard. But this is
not a failure; this will be restored if it is within the normal standard.
3) The LCD contrast varies depending on the visual angle, ambient temperature, power
voltage etc. Obtain the optimum contrast by adjusting the LC dive voltage.
4) When carrying out the test, do not take the module out of the low-temperature space
suddenly. Failure to do so will cause the module condensing, leading to malfunctions.
5) Make certain that each signal noise level is within the standard (L level: 0.2Vdd or less and
H level: 0.8Vdd or more) even if the module has functioned properly. If it is beyond the
standard, the module may often malfunction. In addition, always connect the module when
making noise level measurements.
6) The CMOS ICs are incorporated in the module and the pull-up and pull-down function is not
adopted for the input so avoid putting the input signal open while the power is ON.
7) The characteristic of the semiconductor element changes when it is exposed to light
emissions, therefore ICs on the LCD may malfunction if they receive light emissions. To
prevent these malfunctions, design and assemble ICs so that they are shielded from light
emissions.
8) Crosstalk occurs because of characteristics of the LCD. In general, crosstalk occurs when
the regularized display is maintained. Also, crosstalk is affected by the LC drive voltage.
Design the contents of the display, considering crosstalk.
9.5
Other
1) Do not disassemble or take the LC module into pieces. The LC modules once
disassembled or taken into pieces are not the guarantee articles.
2) The residual image may exist if the same display pattern is shown for hours. This residual
image, however, disappears when another display pattern is shown or the drive is
interrupted and left for a while. But this is not a problem on reliability.
3) AMIPRE will provide one year warranty for all products and three months warrantee for all
repairing products.
Date : 2009/11/19
AMPIRE CO., LTD.
16
10. OUTLINE DIMENSION
Date : 2009/11/19
AMPIRE CO., LTD.
17
Date : 2009/11/19
AMPIRE CO., LTD.
18
11 Packing Condition
Date : 2009/11/19
AMPIRE CO., LTD.
19