FSH10AR - Cynergy3

FSH10AR
Flow switch for G1”, G2”, G3” or G4” pipes
General purpose switch for loads of up to 4A inductive
20 l/min turn on flow rate
Automatic shut down on flow stop
Adjustable time delay from 0 to 10 seconds for
pump stop
1”BSP pipe connections for mounting
Technical Specification
Screw mount Material
Enclosure material
Enclosure rating
Start up flow rate
Max Pressure
Max Temperature
Pipe connections
Pump stop delay range
Brass
Polyamide
IP54
Q. min
P max
T max
l/min
bar
°C
BSP
sec
Electrical Specification
Supply Voltage
Switching Voltage Max
Switching Power Max
Switching Current Max
Vac
Vac
kW
A
Standard Parts
FSH10AR
On flow rate
20 l/min
20
10
100
1”
0 - 10
24 or 240
250
1
10 for resistive load
4A for motor load
Max Power
750
Max Load current
4A
The FSH10AR can be used to control a
pump or some other equipment or process
via a relay output. If used in a pumped
system, the device has to be fitted in the
pipe after the pump.
95
It could be for controlling a circulating or
centrifugal electric pump that is providing
increased pressure or flow within water
systems with storage tanks.
The FSH10 switches the output, once the
flow rate through the pipe exceeds 20
l/min. When used to activate a pump, it
can give an increased flow and pressure,
dependant on the pump capacity.
The turn off time delay is adjustable
between 0 and 10 seconds.
A flow of less than 20 l/min, whether due
to a lack of supply (e.g. tank empty) or to a
decrease in demand(e.g. tap closing), will
turn the output off again.
94
22
113
Cynergy3 Components Ltd.
7 Cobham Road
Ferndown Industrial Estate
Wimborne, Dorset BH21 7PE
Telephone +44 (0) 1202 897969
Email:[email protected]
ISO9001 C E R T I F I E D
www.cynergy3.com
© 2012 Cynergy3 Components, All Rights Reserved. Specifications are subject to change without prior notice. Cynergy3 Components and the Cynergy3 Components logo are trademarks of Cynergy3 Components Limited.
FSH10AR
Flow switch for G1”, G2”, G3” or G4” pipes
Installation information
The flow switch is designed to be used in a horizontal pipe
with the switch mounted through a side entry. Pipe
connection is G1” (1”BSP). The device relies on the flow of
liquid working in opposition to the spring loaded paddle to
operate the relay.
G1” socket connection
The liquid flow moves paddle within the pipe, when the flow
increases beyond the minimum specified level. A magnet
mounted on the head of the paddle closes a magnetic switch
in the control circuit, so causing this to operate the output
relay.
The output relay will remain energised for the time delay set,
if the flow drops below the specified level and the paddle
has returned to the rest position, and will then be deenrgised.
Flow
Direction
The output relay will be energised for the time delay set, if
the unit is disconnected then reconnected to the supply
voltage or the test button is pushed.
G1” - G4” pipe size
G1” mounting thread
The unit can operate on a supply voltage of either 24 or
240ac.
“o” ring seal
The output is a SPCO electromechanical relay with contacts
rated to 10(4)A 250Vac.
Adaptor ring
“o” ring seal
There is a spare terminal connected to the 240Vac supply
that can be used, if a 240Vac supply is being used, to link to
the common contact of the relay, if a 240Vac output is
required.
Output at Zero Flow
Common
Normally open
Normally closed
Power supply
Neutral
24Vac
240Vac
Spare 240Vac
Cynergy3 Components Ltd.
7 Cobham Road
Ferndown Industrial Estate
Wimborne, Dorset BH21 7PE
Telephone +44 (0) 1202 897969
Email:[email protected]
ISO9001 C E R T I F I E D