FSVPLC - Cynergy 3

FSVPLC
Inline Flow Switch for connection to PLC
Signal level output for PLC
0.6 l/min or 3.0 l/min turn on flow rate
Automatic shut down on flow stop
Volt free contact for output to PLC
1”BSP pipe connections
Technical Specification
Flow Tube Material
Start up flow rate
Max flow rate
Max Pressure
Max Temperature
Pipe connections
The FSVPLC can be used to control some
other equipment or process via a PLC. If
used in a pumped system, the device has
to be fitted in the pipe above the pump.
FSVPLC06
FSVPLC30
Brass
Q. min
Q max
P max
T max
l/min
l/min
bar
°C
BSP
Electrical Specification
Output
Max voltage
Switching Current Max
Vac
mA
Standard Parts
FSVPLC06
FSVPLC30
On flow rate
0.6l/min
3.0 l/min
0.6
3.0
80
8
85
1”
SPNO volt free contact
<5
<1
90
The FSVPLC gives a signal to the PLC once
the flow rate through the device exceeds
0.6 l/min, or 3 l/min depending on version.
82
A flow of less than 0.6 l/min , or 3.0 l/min
depending on version, whether due to a
lack of supply (e.g. tank empty) or to a
decrease in demand(e.g. tap closing), will
turn the signal to the control circuit off
again.
Cynergy3 Components Ltd.
7 Cobham Road
Ferndown Industrial Estate
Wimborne, Dorset BH21 7PE
Telephone +44 (0) 1202 897969
Email:[email protected]
ISO9001 C E R T I F I E D
www.cynergy3.com
© 2014 Cynergy3 Components, All Rights Reserved. Specifications are subject to change without prior notice. Cynergy3 Components and the Cynergy3 Components logo are trademarks of Cynergy3 Components Limited.
FSVPLC
Inline Flow Switch for connection to PLC
Installation information
The flow switch must be mounted vertically with the flow
direction upwards. Pipe connection is G1” (1”BSP). The
device relies on the flow of liquid working in opposition to
gravity to operate the switch.
The liquid flow moves a plunger inside the brass flow tube,
when the flow increases beyond the minimum specified level.
A magnet inside the plunger closes a magnetic switch in the
control circuit to the PLC.
The output will open, if the flow drops below the specified
level and the plunger has returned to the lower position
Flow
Direction
The output switch will be closed if the test button is pushed.
The output is a SPNO switch with contacts rated to
1mA/5Vac.
Cynergy3 Components Ltd.
7 Cobham Road
Ferndown Industrial Estate
Wimborne, Dorset BH21 7PE
Telephone +44 (0) 1202 897969
Email:[email protected]
ISO9001 C E R T I F I E D
www.cynergy3.com
© 2012 Cynergy3 Components, All Rights Reserved. Specifications are subject to change without prior notice. Cynergy3 Components and the Cynergy3 Components logo are trademarks of Cynergy3 Components Limited.