FCTE Pump Dry Running Sensor cynergycomponents The FCTE is a heat sensor, which is attached to the outlet pipe from a pump. This device works by reacting to the temperature at the outlet of any centrifugal type pump, which will rapidly rise past 45 ° if the inlet water level falls below the centre line of the inlet. The unit will cut off the electrical supply to the pump, so protecting it from damage. Manual resetting of this unit allows the pump to restart. SPECIFICATION Set Temperature 45°C 113°F Switching voltage max. 250Vac Switching current max. resistive Pipe diameter range 16A 20-200mm IP Rating 21 • Prevents dry-running of pump TE thermostat • Prevents overheating of seals TE thermostat also protects the seal • High power switching capacity T E Heat accumulation zone due to vapour formation Level of water when TE cuts in Dia. m in 20 max Spring clip fixing sensor to pipe 400 Cynergy3 Components Ltd 7 Cobham Road Ferndown Industrial Estate Wimborne Dorset BH21 7PE Tel: +44 (0) 1202 897969 [email protected] ISO 9001C E R T I F IED www.cynergy3.com © 2013 Cynergy3 Components, All Rights Reserved. Specifications are subject to change without prior notice. Cynergy3 Components and the Cynergy3 Components logo are trademarks of Cynergy3 Components Limited. FCTE 2013 FCTE Pump Dry Running Sensor cynergycomponents INSTALLATION Top View 72 46 reset button heat sensor T E 64 46 brass strip 00 ax 4 m 0 in 2 er. m t e d ia m indicator light pipe cable entry spring clip fixing sensor to pipe reset button 46 indicator light cable entry brass heat conductor strip heat sensor 50 20 Side View A-A three-phase motor pump protection examples of positioning pump 16 A 250V thermic relay TE thermostat 250V single - phase motor pump protection ISO 9001C E R T I F IED www.cynergy3.com © 2013 Cynergy3 Components, All Rights Reserved. Specifications are subject to change without prior notice. Cynergy3 Components and the Cynergy3 Components logo are trademarks of Cynergy3 Components Limited.