FSP10 - Cynergy 3

FSP10
Flow switch for direct switching of pump
Direct switching of pumps up to 4A inductive
0.6 l/min or 3.0 l/min turn on flow rate
Automatic shut down on flow stop
Supply and pump electrical connections terminated
within case with cable glands at entry
1”BSP pipe connections
The FSP10 is designed for directly
controlling an electric pump that is
providing increased pressure or flow within
water systems that are gravity fed from
storage tanks. The device has to be fitted
in the pipe above the pump.
The FSP10 starts up the pump when the
flow rate through the device exceeds 0.6
l/min, so giving an increased flow and
pressure, dependant on the pump capacity.
A flow of less than 0.6 l/min , or 3.0 l/min
depending on version, whether due to a
lack of supply (e.g. tank empty) or to a
decrease in demand(e.g. tap closing), will
turn the pump off again.
Technical Specification
Flow Tube Material
Enclosure material
Enclosure rating
Start up flow rate
Max flow rate
Max Pressure
Max Temperature
Pipe connections
Electrical Specification
Supply Voltage
Switching Voltage Max
Switching Power Max
Switching Current Max
FSP10A06
Vac
Vac
kW
A
Standard Parts
FSP10A06
FSP10A30
On flow rate
0.6l/min
3.0 l/min
FSP10A30
Brass
Polyamide
IP54
Q. min
Q max
P max
T max
l/min
l/min
bar
°C
BSP
0.6
3.0
80
8
85
1”
250
250
1
10 for resistive load
4A for motor load
Max Power
750
750
Max Pump current
4A
4A
90
82
Cynergy3 Components Ltd.
7 Cobham Road
Ferndown Industrial Estate
Wimborne, Dorset BH21 7PE
Telephone +44 (0) 1202 897969
Email:[email protected]
ISO9001 C E R T I F I E D
www.cynergy3.com
© 2014 Cynergy3 Components, All Rights Reserved. Specifications are subject to change without prior notice. Cynergy3 Components and the Cynergy3 Components logo are trademarks of Cynergy3 Components Limited.
FSP10
Flow switch for direct switching of pump
The flow switch must be mounted vertically with the flow
direction upwards. Pipe connection is G1” (1”BSP). The
device relies on the flow of liquid working in opposition to
gravity to operate the relay.
The liquid flow moves a plunger inside the brass flow tube,
when the flow increases beyond the minimum specified level.
A magnet inside the plunger closes a magnetic switch in the
control circuit, so causing this to operate the output relay.
The output relay will be de-energised, if the flow drops below
the specified level and the plunger has returned to the lower
position.
The output relay will be energised, if the test button is
pushed.
The unit can only operate on a supply voltage of 240Vac.
The output is 240Vac derived from the supply.
Only for vertical Installation
90
82
Flow direction
Output to Pump
Neutral
Live 240Vac
Ground
Power supply
Ground
Live 240Vac
Neutral
Test button
Power indicator LED
Cynergy3 Components Ltd.
7 Cobham Road
Ferndown Industrial Estate
Wimborne, Dorset BH21 7PE
CERTIFIED
Telephone +44 (0) 1202 897969
Email:[email protected]
www.cynergy3.com
ISO9001
© 2012 Cynergy3 Components, All Rights Reserved. Specifications are subject to change without prior notice. Cynergy3 Components and the Cynergy3 Components logo are trademarks of Cynergy3 Components Limited.
• 7 •