FSP10 Flow switch for direct switching of pump Direct switching of pumps up to 4A inductive 0.6 l/min or 3.0 l/min turn on flow rate Automatic shut down on flow stop Supply and pump electrical connections terminated within case with cable glands at entry 1”BSP pipe connections The FSP10 is designed for directly controlling an electric pump that is providing increased pressure or flow within water systems that are gravity fed from storage tanks. The device has to be fitted in the pipe above the pump. The FSP10 starts up the pump when the flow rate through the device exceeds 0.6 l/min, so giving an increased flow and pressure, dependant on the pump capacity. A flow of less than 0.6 l/min , or 3.0 l/min depending on version, whether due to a lack of supply (e.g. tank empty) or to a decrease in demand(e.g. tap closing), will turn the pump off again. Technical Specification Flow Tube Material Enclosure material Enclosure rating Start up flow rate Max flow rate Max Pressure Max Temperature Pipe connections Electrical Specification Supply Voltage Switching Voltage Max Switching Power Max Switching Current Max FSP10A06 Vac Vac kW A Standard Parts FSP10A06 FSP10A30 On flow rate 0.6l/min 3.0 l/min FSP10A30 Brass Polyamide IP54 Q. min Q max P max T max l/min l/min bar °C BSP 0.6 3.0 80 8 85 1” 250 250 1 10 for resistive load 4A for motor load Max Power 750 750 Max Pump current 4A 4A 90 82 Cynergy3 Components Ltd. 7 Cobham Road Ferndown Industrial Estate Wimborne, Dorset BH21 7PE Telephone +44 (0) 1202 897969 Email:[email protected] ISO9001 C E R T I F I E D www.cynergy3.com © 2014 Cynergy3 Components, All Rights Reserved. Specifications are subject to change without prior notice. Cynergy3 Components and the Cynergy3 Components logo are trademarks of Cynergy3 Components Limited. FSP10 Flow switch for direct switching of pump The flow switch must be mounted vertically with the flow direction upwards. Pipe connection is G1” (1”BSP). The device relies on the flow of liquid working in opposition to gravity to operate the relay. The liquid flow moves a plunger inside the brass flow tube, when the flow increases beyond the minimum specified level. A magnet inside the plunger closes a magnetic switch in the control circuit, so causing this to operate the output relay. The output relay will be de-energised, if the flow drops below the specified level and the plunger has returned to the lower position. The output relay will be energised, if the test button is pushed. The unit can only operate on a supply voltage of 240Vac. The output is 240Vac derived from the supply. Only for vertical Installation 90 82 Flow direction Output to Pump Neutral Live 240Vac Ground Power supply Ground Live 240Vac Neutral Test button Power indicator LED Cynergy3 Components Ltd. 7 Cobham Road Ferndown Industrial Estate Wimborne, Dorset BH21 7PE CERTIFIED Telephone +44 (0) 1202 897969 Email:[email protected] www.cynergy3.com ISO9001 © 2012 Cynergy3 Components, All Rights Reserved. Specifications are subject to change without prior notice. Cynergy3 Components and the Cynergy3 Components logo are trademarks of Cynergy3 Components Limited. • 7 •