DALI Professional Controller-4 Control unit Operating instructions Contents Safety............................................................................................... 4 General instructions Safety instructions 4 4 Description....................................................................................... 5 Purpose and application Configuration Design Connections Pushbutton LED displays 5 5 5 5 5 6 Installation........................................................................................ 8 Fasten control unit Connecting the control unit Safety instructions Preparing the wiring Relays Number of pushbuttons and sensor couplers Pushbutton Connection diagram System overview 8 9 9 10 10 10 10 11 12 Operation....................................................................................... 13 Basic state Construction Site mode Plug & Play mode Further operating functions Offline mode (power supply via the USB interface) Behaviour after a power failure 13 13 15 16 16 17 Appendix........................................................................................ 18 Technical data Applicable standards Notes 18 18 18 3 DALI Professional Controller-4 Safety Safety General instructions The control unit must only be installed and put into operation by a qualified electrician. The applicable safety regulations and accident prevention regulations must be observed. Safety instructions WARNING! Exposed, live cables. Danger of electric shock! • Only work on the control unit when it is de-energised. CAUTION! Destruction of the control unit and other devices through incorrect mounting! • • 4 The control unit should only be mounted in switch cabinets (DIN 43880). The DALI standard as per IEC 62386 must be complied with. III 2010 DALI Professional Controller-4 Description Description Purpose and application The DALI Professional control unit makes scene-based operations and daylight/presence-dependent operations possible. The control unit can control up to 256 (4x64) DALI-operating devices via 4 DALI lines and functions with any other device of the DALI Professional product family. For more detailed information on DALI, see http://www.dali-ag.org/. The gateway is designed for installation on 35 mm DIN rails in switch cabinets. Configuration In order to make use of the control unit‘s full functionality (e.g. brightness control, scenes, sequences, colour control, addressing), you must have a PC configured with the DALI Professional software (see the separate software instructions). Simple light operations (switching on/off, dimming) can be carried out without previous configuration (see „Operation“ in these operating instructions): • With the pushbuttons directly on the device („Construction Site mode“) • With the buttons directly on the device and the motion sensors („Plug & Play Mode“) Design The control unit is made up of the following components: Connections • Power supply (A) • DALI lines (two-pole) A, B, C, D (B) • Relay contacts K1, K2, K3, K4 (C) • USB interface (type B) for PC connection (J) Pushbutton • “SELECT” pushbutton (E) • „ON/OFF/DIM“ pushbutton (F) III 2010 5 DALI Professional Controller-4 Description LED displays „DALIPORT“ (G): Status of the DALI A, B, C, D lines: LED Meaning On Mains voltage present, DALI power supply active. Off No mains voltage present, DALI power supply inactive (control unit supplied only through USB). Flashes Short circuit within the DALI circuit (voltage 0 V). Sparks Overvoltage in the DALI circuit (voltage > 20 V). „RELAY“ (H): Status of the relay outputs K1, K2, K3, K4 LED Meaning On Relay energised. Off Relay de-energised (switching state as on imprint). Flashes See "Construction Site Mode" in "Operation". LEDs for status display of the control unit (K) „PLUG & PLAY“: LED Meaning On Plug & Play mode available (i.e. control unit has not yet been configured by means of PC). Off Plug & Play mode not available (i.e. control unit has been configured by means of PC). „POWER“: LED Meaning On Mains voltage is present. Control unit is operational. Off No mains voltage present. Flashes Startup phase (approx. 10 s) after a power failure. „OFFLINE“ 6 LED Meaning On No mains voltage present. The control unit is not supplied with mains voltage, but instead via the USB interface. "Offline mode (power supply via the USB interface)". III 2010 DALI Professional Controller-4 Description „ERROR“ LED Meaning On Lamp faults detected. Off Normal operation. „SERVICE“: (D) LED Meaning On/Off Reserved for future applications E F G J K D H C III 2010 B A 7 DALI Professional Controller-4 Installation Installation Fasten control unit The DALI Professional control unit is only intended to be mounted on 35 mm DIN rails in a switch cabinet, as per DIN 43880. It requires an installation width of 9 horizontal pitch units (HP). Proceed as follows: Step Task 1 Press in lock clips until you hear them lock with a "click" sound. 2 Lock in the control unit on the DIN rail. Removal: Using a screwdriver, push out the lock clips. 8 III 2010 DALI Professional Controller-4 Installation Connecting the control unit Safety instructions WARNING! Protection Class I device. Danger of electric shock! • • Securely connect the protective earth (PE). Use B 10 A or B 16 A type unit as circuit breaker. WARNING! The DALI interface is insulated by a basic insulation. Danger of electric shock! • • Use wires that can handle power line voltages for the entire DALI wiring. • Do not connect the DALI wiring with external voltage, especially not with 230 V mains voltage. Any potential overvoltage is only checked when starting up the DALI Professional. Include DALI wiring, with a 5-core cable (e.g. NYM 5 x 1.5 mm²) if necessary, together with the mains voltage (L, N, PE). CAUTION! Destruction of the control unit and other devices through incorrect mounting! • • • III 2010 Connect relay contacts with max. 5 A ohmic load. Connect an interference suppressed contactor in between for higher loads. Using electronic ballast reduces the switching load, with respect to ohmic loads, at the same wattage. 9 DALI Professional Controller-4 Installation Preparing the wiring Wire stripping for connecting the relays, DALI and mains cables to the plug-in terminals: 10-12 mm. 10 - 12 mm Relays Depending on the connection, the relays function as break contact, make contact or make/break contact: Relays Connection to K1, K2, K3, K4 Break contact Make contact Make/break contact Number of pushbuttons and sensor couplers If a 64 EVG is connected to a DALI circuit, the maximum drive current available in this DALI circuit is 70 mA. Specific power consumption of the couplers: • DALI Professional sensor coupler: 5 mA • DALI Professional pushbutton coupler: 6 mA à Connection examples of a DALI circuit: • 14 Sensor couplers • 10 Pushbutton couplers and 2 Sensor couplers If more couplers are required, the number of EVG in the DALI can be reduced. A maximum of 64 DALI coupler addresses are available for each DALI circuit. OSRAM DALI couplers can also be deployed across all circuits. Pushbutton Standard commercial pushbuttons can be connected to the pushbutton couplers or – via an e:bus DALI gateway – capacitive glass touch control elements and touchscreens as well. See separate operating instructions. 10 III 2010 DALI Professional Controller-4 Installation Connection diagram L1 L2 L3 N PE F2 F1 F3 DALI PROFESSIONAL CONTROLLER-4 K1 K2 K3 K4 A DA + - B DA + - C DA + - D DA + - NC PE N L Analog wiring of the B, C and D circuits 220 -240 V DA DA 220 -240 V DA DA DA DA DA DA DA DA C D DALI ECG A1 21 22 23 24 25 26 27 28 DALI ECG A2 21 22 23 24 25 26 27 28 Sensor 4 DALI Professional Sensor coupler Light and motion sensor DALI Professional Pushbutton coupler A B 220 -240 V DA DA 220 -240 V DA DA C D DALI Professional Pushbutton coupler A B DA DA 220 -240 V DA DA DA DA DA DA 220 -240 V DA DA III 2010 DALI ECG A3 21 22 23 24 25 26 27 28 DALI ECG A62 21 22 23 24 25 26 27 28 DALI ECG A63 21 22 23 24 25 26 27 28 4 Sensor DALI Professional Sensor coupler Light and motion sensor DALI ECG A64 21 22 23 24 25 26 27 28 11 DALI Professional Controller-4 Installation System overview USB 1 2 3 4 5 6 7 8 64 1 2 3 4 5 6 7 8 64 1 2 3 4 5 6 7 8 64 1 2 3 4 5 6 7 8 64 Pushbutton coupler Sensor coupler Light and motion sensor 12 III 2010 DALI Professional Controller-4 Operation Operation Basic state After initial connection to mains voltage, the control unit is in its basic state: • Energised with mains voltage.. à LED „POWER“ blinks for approx. 10 seconds and then lights up continuously. • DALI power supply is active.. à LEDs „DALIPORT“ lights up continuously. • Relays de-energised.. à LEDs „RELAY“ have been switched off. • Plug & Play mode available if the control unit has not yet been configured by PC.. à LED „PLUG & PLAY“ lights up continuously. Construction Site mode In the Construction Site mode the DALI circuits and relays can be energised individually by means of the „SELECT“ and „ON/OFF/DIM“ pushbuttons, and the DALI circuits can also be dimmed. Prerequisite: mains voltage present. Procedure (example) Pushbutton Pushbutton: SELECT ON/OFF/DIM State/change Basic state: All four "DALIPORT" LEDs light up. 1. Long press 1. Press A DALI broadcast RESET is transmitted. All connected EVGs and couplers are reset to their factory settings. The entire system is in a defined state. Only the "DALIPORT A" LEDs light up. . Only the EVGs connected to DALI circuit A can be operated with ON/OFF/DIM. 1. Short press All EVGs connected to DALI circuit A are switched on to their maximum value. 2. Short press All EVGs connected to DALI circuit A are switched off. 1. Long press All EVGs connected to DALI circuit A are dimmed. 2. Long press Reversing the dimming direction. . Each repeated long press of the button causes a toggle between increased brightness and decreased brightness. 2. Press Only the "DALIPORT B" LEDs light up. . Only the EVGs connected to DALI circuit B can be operated with ON/OFF/DIM. Analog . DALI circuit A III 2010 13 DALI Professional Controller-4 Operation Pushbutton Pushbutton: SELECT ON/OFF/DIM State/change 3. Press Only the "DALIPORT C" LEDs light up. . Only the EVGs connected to DALI circuit C can be operated with ON/OFF/DIM. Analog . DALI circuit A 4. Press Only the "DALIPORT D" LEDs light up. . Only the EVGs connected to DALI circuit D can be operated with ON/OFF/DIM. Analog . DALI circuit A 5. Press "RELAY K1" LED blinks rapidly. Relay K1 has been selected and is operable. 1. Short press Relay K1 is audibly energised and the LED blinks slower. 6. Press "RELAY K1" lights up. Relay K1 is energised.. "RELAY K2" LED blinks rapidly. Relay K2 has been selected and is operable. 7. Press "RELAY K1" lights up. Relay K1 is energised.. "RELAY K2" LED is off. Relay K2 is still de-energised. . "RELAY K3" LED blinks rapidly. Relay K3 has been selected and is operable. 8. Press "RELAY K1" lights up. Relay K1 is energised. . "RELAY K2" and "RELAY K3" LEDs are off. K2 and K3 relays are still de-energised . "RELAY K4" LED blinks rapidly. Relay K4 has been selected and is operable. 9. Press 1. Short press Relay K4 is audibly energised and the LED blinks slower. 2. Short press Relay K4 is audibly energised and the LED blinks rapidly again. All four "DALIPORT" LEDs light up.. The "RELAY K1" LED lights up because relay K1 is the only one in the switching state "energised". If no operations are performed for approx. 30 seconds, the control unit returns to its basic state. Switching or dimming states are retained, however, and – in the case of the relays – are also displayed by the LEDs. Note:. If the control unit has been configured by means of PC, the changed switching or dimming states are retained for approx. 30 seconds. Afterward, the state prior to manual operation is restored again (the activity is comparable with the restoring of voltage after a power failure). 14 III 2010 DALI Professional Controller-4 Operation Plug & Play mode Simple light controls with motion detection can be set up in the Plug & Play mode by connecting DALI Professional pushbutton couplers and DALI Professional sensors. The Plug & Play mode is only available if the control unit has not yet been configured by means of PC and the „PLUG & PLAY“ LED is lit up. Note: - Pushbutton and sensor switching operations only affect the DALI circuit to which the respective pushbutton coupler or sensor coupler is connected. - Light sensors do not have a function. Symbols Switch on Luminaires on Switch off Luminaires off Short press . (< 0.5 s) Long press . (0.5 – 4 s) Pushbutton on the luminaire Principle Luminaire OFF Pushbutton pressed? no Motion? yes max. no yes Luminaire ON Pushbutton pressed? yes 5 min no no Motion? yes Luminaires manually switched off before max. 30 s? no Luminaire ON max. yes III 2010 15 DALI Professional Controller-4 Operation Systems RESET With the systems RESET, all connected devices can be reset to the factory default settings: Press the „ON/OFF/DIM“ pushbutton for 10 s to carry the systems RESET. Operation • Switch luminaires: via short press. 2x A max ... B A max • Dimming luminaires: via long press. Each repeated long press of the button causes a toggle between increased brightness and decreased brightness. ... B Further operating functions Further operating functions can be configured with the DALI Professional software (see the separate software operating instructions): • Assignment of the pushbutton functions, classified by short press, long press and „double press“. • Free assignment of the pushbuttons and sensors to EVG groups (also across all DALI circuits). • Setting up scheduled activity procedures. Offline mode (power supply via the USB interface) The control unit can be operated in the Offline mode for special applications, such as for a firmware update or the reading out of serial and version numbers, for example: • The control unit is not supplied with mains voltage, but instead via the USB interface. • DALI circuits are not supplied with voltage. • The „SELECT“ and „ON/OFF/DIM“ pushbutton do not have a function. Step 1 Task Disconnect power supply. à "POWER" LED is switched off. à "DALIPORT" LEDs are switched off. 2 The control unit is connected with the PC via the USB interface.. à "OFFLINE" LED lights up continuously. 16 III 2010 DALI Professional Controller-4 Operation Behaviour after a power failure In the Construction Site or Plug & Play mode After voltage is restored to the control unit again with the pushbuttons, the state that existed before the power failure is restored: • Relay states are retained. • EVGs call up the state that existed prior to power failure („last level“). If the EVGs are still supplied with voltage from another power supply line, these call up – consequent to the lacking DALI communication – until voltage restoration reaches the system failure level of 100% that is set at the factory. With previous configuration by means of the DALI Professional software After voltage is restored to the control unit again, the state that existed before the power failure is restored by means of the DALI Professional software. Activity procedures taking place at the time of the power failure are not recontinued or restarted after voltage is restored. III 2010 17 DALI Professional Controller-4 Appendix Appendix Technical data Operating voltage 100-240 V AC/ 50-60 Hz (DC operation permissible) Max. power consumption under full DALI load 25 W Working temperature 0 °C … +40 °C Protection type IP 20 Protection class I Leads diameter 0.5 ... 2.5 mm² (fixed). 0.5 ... 1.5 mm² (flexible) DALI power supply 4x 200 mA (basically insulated) Max. number of DALI EVGs (addressed) 4 x 64 Weight 400 g Dimensions (L x W x H) 160 x 91 x 62 mm (9 HP) Applicable standards DALI standard IEC 62386 Safety EN 60950 EMC emission EN 55022 EMC resistance IEC/EN 61000 Conformity with the relevant EU directives is confirmed by the CE symbol. Notes Address 18 Circuit Name Type Comments III 2010 Address Circuit Name Type Comments Address Circuit Name Type III 2010 DALI-PRO-Cont-4_ba1003en_we1.01.indd OSRAM GmbH Kunden Service Center. Customer-Service-Center (CSC) Steinerne Furt 62. 86167 Augsburg. Germany Tel.: +49 (0) 1803 677 - 200 . (kostenpflichtig / charges apply). Fax.: +49 (0) 1803 677 - 202 www.osram.com www.osram.de 40083214789488 4008321478948 ZNN 2603769 000 00 B Comments