OTi DALI 35/220-240/1A0 LT2

OPTOTRONIC® LED Power Supply
Product Data Sheet
OTi DALI 35/220-240/1A0 LT2
SELV Constant current LED driver
Wide operating area up to 1 A - dimmable
The reliable choice for the energy saving lighting:
DALI dimmable, embedded corridor functionality
and advanced Touch Dim with daylight harvesting,
constant lumen output. Digitally programmable.
Automatic current set through the LEDSet interface.
L
B
H
103mm
67mm
29,5mm
Benefits
Wide operating range: 0.35 – 1 A
Adjustable current via LEDset or via software.
Long lasting and high reliability.
Built-in and independent mounting (with opt. kit)
Suitable for emergency lighting units.
Applications
Downlight and spot.
Office – industrial - shop
Approval marks
SELV equivalent
Housing material: plastic, white.
In preparation,
Product Features

Output current range 0.35 – 1 A

Overload protection

Smart dimming down to 1%

Overtemperature protection

Fully digitally programmable

Load hot plug protection

SELV-equivalent, Uout: 15 – 54 VDC

100’000 h lifetime at tc = 65°C

Output power up to 35 W

tc max = 75 °C

Mains voltage 220 – 240 V

Wide ta range -20 – +50 °C

Suitable for emergency lighting

5 years guarantee
1
Edition: 02 Feb 2014
Ver.: 1.0
Status: Valid
Misprints and technical changes excepted
OPTOTRONIC® LED Power Supply
OTi DALI 35/220-240/1A0 LT2 Product Data Sheet
ENVIRONMENT
DIMMING
OUTPUT
INPUT
Electrical Specifications
Item
Nominal voltage
Nominal frequency
AC voltage range
DC voltage range
Maximum voltage
Nominal current
Total Harmonic Distortion (THD)
Power factor
Efficiency
Power losses
No-load power
Stand-by power
Protection class
Inrush current
Max. units per circuit breaker
Value
220 – 240
0 / 50 / 60
198 – 264
176 – 276
280
0.18
< 10
> 0.95
typical 86%
5.7
n/a
< 350
II
< 20
B16: 55; B10: 33
Unit
V
Hz
V
V
Vac
A
%
Nominal voltage range
Maximum voltage
15 – 54
60
Nominal current range
350-1050
V
V
mA
Current accuracy
Current ripple
Nominal power range
Maximum power
Galvanic isolation
Dimming control
Dimming range
Dimming technique
PWM frequency
Galvanic isolation
Ambient temperature range ta
Maximum case temperature tc
Max. case temp. in fault condition
Storage temperature range
Relative humidity
Surge transient protection
Environmental rating
IP rating
Mains switching cycles
+/- 5
<2
15 – 35
35
SELV equivalent
yes
1 – 100
mixed
> 280
basic / double
-20 …+50
75
110
-25 …+85
5 ... 85
1
Indoor
IP 20
> 100’000
50’000
100’000
Expected lifetime
%
W
W
mW
A pk
%
%
W
W
%
Remarks
Incl. DC or pulse DC
DC or pulse DC
2 h maximum, unit might not operate in this abnormal condition
Full load, 220 – 240 V, 50 Hz / see graphs
Full load, 220 – 240 V, 50 Hz / see graphs
Full load, 220 – 240 V, 50 Hz / see graphs
Maximum, full load
Load switching on output side is safe but not permitted
Suitable for class I and II luminaires
Max, Th < 100 μs
No load protection, restart trials every 1-3 s
LEDset open: 175 mA; LEDset short: 700 mA (digitally
programmable)
Digital programming. +/- 5% through the LEDset interface.
Ripple / average @ 100 Hz; Full load
LED output
Output to earth - Touch current < 0.7 mA
DALI, TouchDIM
Of selected nominal current
AM (>260mA) + PWM (<260mA)
Hz
Basic DALI to Primary / Double DALI to Secondary
°C
°C
°C
°C
%
kV
h
Measured on tc point indicated of the product label, ta not exceeded
Not condensing
L/N acc to. EN 61547
tc = 75°C, 0.2% / 1’000 h failure rate
tc = 65°C, 0.1% / 1’000 h failure rate
Protections
Overtemperature, Overload, No load, Short-circuit, Input overvoltage, Output overvoltage, Output undervoltage
See remarks on page 4.
Wiring Diagram
Input
Gray
Gray
RED
RED
Output
Black
White
Black
Red
1 - Mains
2 - Mains
4 – DALI
5 – DALI
21 - LED-aux
22 - LEDset
23 - LED 24 - LED +
Load wires length: 2m max.


2
Wires cross section: massive leads 0,2-1,5 mm / flexible leads 0,2 – 1,5 mm
Wire peeling length: 8-9 mm
2
2
Edition: 05 Feb. 2014
Ver.: 1.0
Status: Valid
Misprints and technical changes excepted
OPTOTRONIC® LED Power Supply
OTi DALI 35/220-240/1A0 LT2 Product Data Sheet
Typical Operating window
Typical Efficiency vs load
60
55
54V
50
45
PWM dimming
min 1%
35W
Uout [V]
40
Rated
35
30
25
350mA
15W
Working
20
15V
15
10
0,000
0,100
0,200
0,300
0,400
0,500
0,600
Iout [A]
0,700
0,800
Typical Power factor vs load
0,900
1,000
1,100
Typical THD vs load
THD vs Output Power - 230V 50Hz
14
12
I_thd [%]
10
8
6
4
2
0
10
15
20
25
30
35
Output Power [W]
Typical Iout vs Rset
Rset formula and standard Iout values
I OUT A  
5V
1000
Rset  
Iout [mA]
Iout [mA]
nominal
actual
Rset [kOhm]
E48 series
350
357
14
700
699
7.15
1050
1050*
4.64
*Rset value set Iout = 1078 mA but Iout is internal limited to 1050 mA
lease refer to “Typical Iout vs. Rset” graph.
3
Edition: 05 Feb. 2014
Ver.: 1.0
Status: Valid
Misprints and technical changes excepted
OPTOTRONIC® LED Power Supply
L
L1
L2
B
B1
B2
H
d
OTi DALI 35/220-240/1A0 LT2 Product Data Sheet
103mm
94mm
138mm
67mm
58mm
57,7mm
29,5mm
Ø4,2
Remarks











Input over voltage protection: mains up to 280 Vac, for two hours maximum, will not destroy both the unit and the load;
shut down of load might occur in this condition.
Output short circuit / undervoltage protection: shut down of load happens if Uout is below 15 V (typ. 12 V); the unit
automatically tries to switch on the load again every 1 s for 0.5 s delivering the selected nominal current.
Output overload protection: the unit automatically reduces the output current to keep the output power below 35W .
Output over voltage protection: shut down of load happens if Uout exceeds 54V (typ. 55V); the unit automatically tries to switch
on the load again every 1 s for 0.5 s delivering the selected nominal current.
No load operation: the unit automatically tries to switch on the load delivering the selected nominal current; despite this operation
mode is safe for both unit and load, it is not recommended. Do not put a switch between load and unit.
Over temperature protection: the unit is protected against temporary overheating by automatic reduction of the output current.
The protection is self restoring.
Touch current: lower than 0.7 mA, according to EN 60598-1 annex G and EN 61347-2-13 annex A. Max. 2 ECG per luminiare,
each ECG supplying separately its load (two or more units cannot be connected together on secondary side).
Switchover time: typical 0.6s, both AC and DC mains.
Output power hold time: ≤ 2 ms, in case of mains dips.
Emergency lighting: this LED power supply is suitable for emergency lighting fixtures acc. to EN 60598-2-22, with emergency
output factor EOFI = 0,15 ( default value, can be programmed up to EOFI = 1) and related duration time of 10 h at least. Function in
emergency is ensured up to ta = 80°C and tc = 92°C.
HOT Plug: connection of LED on secondary is allowed without damage of LED. LED turns on automatically
Standards
Ordering information
EN 61347-1
Product name
Type
EAN10
EAN40
NAED
EN 61347-2-13
OTi DALI 35/220-240/1A0 LT2
AA62433
4052899919440
4052899919518
n/a
EN 55015
OT Cable Clamp B-style
4052899077898
Pieces / box
20
20
EN 61547
EN 61000-3-2
EN 62384
EN 62386
Disclaimer (Engineering Samples)
This product is a demonstration model from our development laboratories made available for your information only.
The model is not binding in respect to its fitness for use, i.e. service life, luminous flux, color temperature and performance.
Prior to production the design, including dimensions, is subject to modification.
You will, therefore, appreciate that at this stage of development we are unable to assume any liability also for damages which may be caused by this product.
Should you urgently require binding information for the preparation of construction data for your applications, please contact our marketing department.
Manufacturer’s address:
OSRAM GmbH
Steinerne Furt 62
D-86167 Augsburg
Germany
www.osram.com
Technical support:
Kunden Service Center Germany
+49 (0)89-6213-60 00
4
Edition: 05 Feb. 2014
Ver.: 1.0
Status: Valid
Misprints and technical changes excepted