OPTOTRONIC® LED Power Supply Product Data Sheet OTi DALI 80/220-240/2A1 LT2 L SELV Constant current LED driver Wide operating area up to 2.1 A - dimmable The reliable choice for the energy saving lighting: DALI dimmable, embedded corridor functionality and advanced Touch Dim with daylight harvesting, constant lumen output. Digitally programmable. Automatic current set through the LEDSet interface. Benefits Wide operating range: 1.0 – 2.1 A Adjustable current via LEDset or via software. Long lasting and high reliability. Slim white metal housing 30 x 21 mm. Double output connectors (parallel connection). Suitable for emergency lighting units. Applications Linear and area lighting. Office – industrial - shop Housing material: metal, white painted. Approval marks SELV equivalent In preparation, if not already printed on product label Product Features Output current range 1.0 – 2.1 A Overload protection Smart dimming down to 1% Overtemperature protection Very low output current ripple Fully digitally programmable SELV equivalent Uout: 20 – 54 V 100’000 h lifetime at tc = 70°C Output power up to 80 W tc max = 80 °C Mains voltage 220 – 240 V Wide ta range -25 – +45 °C Suitable for emergency lighting 5 years guarantee 1 Edition: 06 Feb. 2014 Ver.: 2.2 Status: Released OPTOTRONIC® LED Power Supply OTi DALI 80/220-240/2A1 LT2 L Product Data Sheet ENVIRONMENT DIMMING OUTPUT INPUT Electrical Specifications Item Nominal voltage Nominal frequency AC voltage range DC voltage range Maximum voltage Nominal current Total Harmonic Distortion (THD) Power factor Efficiency Power losses No-load power Stand-by power Protection class Inrush current Max. units per circuit breaker PE current Nominal voltage range Maximum voltage Nominal current range Current accuracy Current ripple Nominal power range Maximum power Galvanic isolation Dimming control Dimming range Dimming technique Frequency Galvanic isolation Ambient temperature range ta Maximum case temperature tc Max. case temp. in fault condition Storage temperature range Relative humidity Surge transient protection Environmental rating IP rating Mains switching cycles Expected lifetime Value 220 – 240 0 / 50 - 60 198 – 264 176 – 276 350 0.43 < 20 > 0.95 > 90 9.0 n/a < 500 I 53 B16: 13; B10: 8 < 0.5 20 – 54 60 1000 – 2100 +/- 5 < 200 32 – 80 83 SELV equivalent yes 1 – 100 mixed > 450 basic / double -25 …+45 80 120 -25 …+85 5 ... 85 1|2 Indoor IP 20 > 100’000 50’000 100’000 Unit V Hz V V Vac A % % W W mW A pk mA V V mA % mApk W W % Hz °C °C °C °C % kV h Remarks Incl. DC or pulse DC DC or pulse DC 2 h maximum, unit might not operate in this abnormal condition Full load, 220 – 240 V, 50 Hz / see graphs Full load, 220 – 240 V, 50 Hz / see graphs Full load, 220 – 240 V, 50 Hz / see graphs Maximum, full load Load switching on output side is safe but not permitted PE can be connected either to terminal or housing Max, th = 200 μs I max = 53 A Th = 200 μs Through PE, output floating No load protection, restart trials every 2-3 s LEDset open: 500 mA; LEDset short: 2.1 A (digitally programmable) High frequency ripple (peak); low freq. ripple is negligible Dimmable down to 0.2W Output and LEDset to mains - Touch current < 0.7 mA DALI and TouchDIM Of selected nominal current 1 – 30% PWM, 30 – 70% amplitude 1 – 30%; Basic DALI to primary-earth / Double DALI to secondary Measured on tc point indicated of the product label Not condensing L/N | LN/PE acc to. EN 61547-5.7 tc = 80°C, 0.2% / 1’000 h failure rate, 14 h ON / 10 h Stan-by per day tc = 70°C, 0.1% / 1’000 h failure rate, 14 h ON / 10 h Stan-by per day Protections Overtemperature, Overload, No load, Short-circuit, Input overvoltage, Output overvoltage, Output undervoltage See remarks on page 4. Wiring Diagram Two or more units cannot be connected together on secondary side with any or more of the 21 … 27 terminals. 2 Edition: 06 Feb. 2014 Ver.: 2.2 Status: Released OPTOTRONIC® LED Power Supply Typical Operating window Dimming operating area OTi DALI 80/220-240/2A1 LT2 L Product Data Sheet Typical Efficiency vs load Rated operating area Typical Power factor vs load Typical THD vs load Typical Iout vs Rset Rset formula and standard Iout values I OUT A 5V 1000 Rset Iout [mA] Iout [mA] nominal set, +/-5% Rset [kOhm] E48 series 1064 1027 1389 1437 1667 1661 2100 2100 4.7 (E24) 4.87 (E48) 3.6 (E24) 3.48 (E48) 3.0 (E24) 3.01 (E48) 2.2 (E24) 2.37 (E48) 1050 1400 1600 2100 Refer to the LEDset application note for further details. 3 Edition: 06 Feb. 2014 Ver.: 2.2 Status: Released OPTOTRONIC® LED Power Supply OTi DALI 80/220-240/2A1 LT2 L Product Data Sheet Remarks Input over voltage protection: mains up to 350 Vac, for one hour maximum, will not destroy both the unit and the load; shut down of load might occur in this condition. Output short circuit / undervoltage protection: shut down of load happens if Uout is below 20V (typ. 18V); the unit automatically tries to switch on the load again every 2-3 s for 0.1 s delivering the selected nominal current. Output overload protection: the unit automatically reduces the output current to keep the output power below 54W . Output over voltage protection: shut down of load happens if Uout exceeds 54V (typ. 55V); the unit automatically tries to switch on the load again every 2-3 s for 0.1 s delivering the selected nominal current. No load operation: the unit automatically tries to switch on the load every 2-3 s for 0.1 s delivering the selected nominal current; despite this operation mode is safe for both unit and load, it is not recommended. Do not put a switch between load and unit. Over temperature protection: the unit is protected against temporary overheating by automatic reduction of the output current when 80°C < tc < 95°C typ., and by automatic power off if 95°C < tc < 100° typ. The protection is self restoring. Touch current: lower than 0.7 mA, according to EN 60598-1 ann. G and EN 61347-1 ann. A Switchover time: lower than 0.5 s, both AC and DC mains. Output power hold time: > 4 ms, in case of mains dips. Emergency lighting: this LED power supply is suitable for emergency lighting fixtures acc. to EN 60598-2-22; EOFI = 1% - 100% according to EN61347-2-13 ann J. Continuous output power at ta = 80°C up to 30 W. Standards Ordering information EN 61347-1 Product name Type EAN10 EAN40 NAED EN 61347-2-13 OTi DALI 80/220-240/2A1 LT2 L AA57587 4052899028050 4052899028067 n/a Pieces / box 20 EN 55015 EN 61547 EN 61000-3-2 EN 62384 EN 62386 Manufacturer’s address: Technical support: OSRAM GmbH Kunden Service Center Germany +49 (0)89-6213-60 00 Steinerne Furt 62 D-86167 Augsburg Germany www.osram.com 4 Edition: 06 Feb. 2014 Ver.: 2.2 Status: Released