pdf

OPTOTRONIC® LED Power Supply
Product Data Sheet
OTi DALI 80/220-240/2A1 LT2 L
SELV Constant current LED driver
Wide operating area up to 2.1 A - dimmable
The reliable choice for the energy saving lighting:
DALI dimmable, embedded corridor functionality
and advanced Touch Dim with daylight harvesting,
constant lumen output. Digitally programmable.
Automatic current set through the LEDSet interface.
Benefits
Wide operating range: 1.0 – 2.1 A
Adjustable current via LEDset or via software.
Long lasting and high reliability.
Slim white metal housing 30 x 21 mm.
Double output connectors (parallel connection).
Suitable for emergency lighting units.
Applications
Linear and area lighting.
Office – industrial - shop
Housing material: metal, white painted.
Approval marks
SELV equivalent
In preparation, if not already printed on product label
Product Features

Output current range 1.0 – 2.1 A

Overload protection

Smart dimming down to 1%

Overtemperature protection

Very low output current ripple

Fully digitally programmable

SELV equivalent Uout: 20 – 54 V

100’000 h lifetime at tc = 70°C

Output power up to 80 W

tc max = 80 °C

Mains voltage 220 – 240 V

Wide ta range -25 – +45 °C

Suitable for emergency lighting

5 years guarantee
1
Edition: 06 Feb. 2014
Ver.: 2.2
Status: Released
OPTOTRONIC® LED Power Supply
OTi DALI 80/220-240/2A1 LT2 L
Product Data Sheet
ENVIRONMENT
DIMMING
OUTPUT
INPUT
Electrical Specifications
Item
Nominal voltage
Nominal frequency
AC voltage range
DC voltage range
Maximum voltage
Nominal current
Total Harmonic Distortion (THD)
Power factor
Efficiency
Power losses
No-load power
Stand-by power
Protection class
Inrush current
Max. units per circuit breaker
PE current
Nominal voltage range
Maximum voltage
Nominal current range
Current accuracy
Current ripple
Nominal power range
Maximum power
Galvanic isolation
Dimming control
Dimming range
Dimming technique
Frequency
Galvanic isolation
Ambient temperature range ta
Maximum case temperature tc
Max. case temp. in fault condition
Storage temperature range
Relative humidity
Surge transient protection
Environmental rating
IP rating
Mains switching cycles
Expected lifetime
Value
220 – 240
0 / 50 - 60
198 – 264
176 – 276
350
0.43
< 20
> 0.95
> 90
9.0
n/a
< 500
I
53
B16: 13; B10: 8
< 0.5
20 – 54
60
1000 – 2100
+/- 5
< 200
32 – 80
83
SELV equivalent
yes
1 – 100
mixed
> 450
basic / double
-25 …+45
80
120
-25 …+85
5 ... 85
1|2
Indoor
IP 20
> 100’000
50’000
100’000
Unit
V
Hz
V
V
Vac
A
%
%
W
W
mW
A pk
mA
V
V
mA
%
mApk
W
W
%
Hz
°C
°C
°C
°C
%
kV
h
Remarks
Incl. DC or pulse DC
DC or pulse DC
2 h maximum, unit might not operate in this abnormal condition
Full load, 220 – 240 V, 50 Hz / see graphs
Full load, 220 – 240 V, 50 Hz / see graphs
Full load, 220 – 240 V, 50 Hz / see graphs
Maximum, full load
Load switching on output side is safe but not permitted
PE can be connected either to terminal or housing
Max, th = 200 μs
I max = 53 A Th = 200 μs
Through PE, output floating
No load protection, restart trials every 2-3 s
LEDset open: 500 mA; LEDset short: 2.1 A (digitally programmable)
High frequency ripple (peak); low freq. ripple is negligible
Dimmable down to 0.2W
Output and LEDset to mains - Touch current < 0.7 mA
DALI and TouchDIM
Of selected nominal current
1 – 30% PWM, 30 – 70% amplitude
1 – 30%;
Basic DALI to primary-earth / Double DALI to secondary
Measured on tc point indicated of the product label
Not condensing
L/N | LN/PE acc to. EN 61547-5.7
tc = 80°C, 0.2% / 1’000 h failure rate, 14 h ON / 10 h Stan-by per day
tc = 70°C, 0.1% / 1’000 h failure rate, 14 h ON / 10 h Stan-by per day
Protections
Overtemperature, Overload, No load, Short-circuit, Input overvoltage, Output overvoltage, Output undervoltage
See remarks on page 4.
Wiring Diagram
Two or more units cannot be connected together on secondary side with any or more of the 21 … 27 terminals.
2
Edition: 06 Feb. 2014
Ver.: 2.2
Status: Released
OPTOTRONIC® LED Power Supply
Typical Operating window
Dimming
operating
area
OTi DALI 80/220-240/2A1 LT2 L
Product Data Sheet
Typical Efficiency vs load
Rated
operating
area
Typical Power factor vs load
Typical THD vs load
Typical Iout vs Rset
Rset formula and standard Iout values
I OUT A  
5V
1000
Rset  
Iout [mA]
Iout [mA]
nominal
set, +/-5%
Rset [kOhm]
E48 series
1064
1027
1389
1437
1667
1661
2100
2100
4.7 (E24)
4.87 (E48)
3.6 (E24)
3.48 (E48)
3.0 (E24)
3.01 (E48)
2.2 (E24)
2.37 (E48)
1050
1400
1600
2100
Refer to the LEDset application note for further details.
3
Edition: 06 Feb. 2014
Ver.: 2.2
Status: Released
OPTOTRONIC® LED Power Supply
OTi DALI 80/220-240/2A1 LT2 L
Product Data Sheet
Remarks










Input over voltage protection: mains up to 350 Vac, for one hour maximum, will not destroy both the unit and the load;
shut down of load might occur in this condition.
Output short circuit / undervoltage protection: shut down of load happens if Uout is below 20V (typ. 18V); the unit automatically
tries to switch on the load again every 2-3 s for 0.1 s delivering the selected nominal current.
Output overload protection: the unit automatically reduces the output current to keep the output power below 54W .
Output over voltage protection: shut down of load happens if Uout exceeds 54V (typ. 55V); the unit automatically tries to switch
on the load again every 2-3 s for 0.1 s delivering the selected nominal current.
No load operation: the unit automatically tries to switch on the load every 2-3 s for 0.1 s delivering the selected nominal current;
despite this operation mode is safe for both unit and load, it is not recommended. Do not put a switch between load and unit.
Over temperature protection: the unit is protected against temporary overheating by automatic reduction of the output current
when 80°C < tc < 95°C typ., and by automatic power off if 95°C < tc < 100° typ. The protection is self restoring.
Touch current: lower than 0.7 mA, according to EN 60598-1 ann. G and EN 61347-1 ann. A
Switchover time: lower than 0.5 s, both AC and DC mains.
Output power hold time: > 4 ms, in case of mains dips.
Emergency lighting: this LED power supply is suitable for emergency lighting fixtures acc. to EN 60598-2-22;
EOFI = 1% - 100% according to EN61347-2-13 ann J. Continuous output power at ta = 80°C up to 30 W.
Standards
Ordering information
EN 61347-1
Product name
Type
EAN10
EAN40
NAED
EN 61347-2-13
OTi DALI 80/220-240/2A1 LT2 L
AA57587
4052899028050
4052899028067
n/a
Pieces / box
20
EN 55015
EN 61547
EN 61000-3-2
EN 62384
EN 62386
Manufacturer’s address:
Technical support:
OSRAM GmbH
Kunden Service Center Germany
+49 (0)89-6213-60 00
Steinerne Furt 62
D-86167 Augsburg
Germany
www.osram.com
4
Edition: 06 Feb. 2014
Ver.: 2.2
Status: Released