pdf

OPTOTRONIC® LED Power Supply
Product Data Sheet
OTi DALI 35/220-240/700 LT2 L
SELV Constant current LED driver
Wide operating area up to 700 mA - dimmable
The reliable choice for the energy saving lighting:
DALI dimmable, embedded corridor functionality
and advanced Touch Dim with daylight harvesting,
constant lumen output. Digitally configurable.
Automatic current set through the LEDSet interface.
Benefits
Wide operating range: 200 – 700 mA
Adjustable current via LEDset or via software.
Zero LF ripple, mobile’s camera friendly.
Long lasting and high reliability.
Slim white metal housing 30 x 21 mm.
Double output connectors (parallel connection).
Suitable for emergency lighting units.
Applications
Linear and area lighting.
Office – industrial - shop
Housing material: metal, white painted.
Approval marks
SELV equivalent
In preparation, if not already printed on product label
Product Features

Output current range 200 – 700 mA

Overload protection

Smart dimming down to 1%

Overtemperature protection

Zero low frequency ripple

Fully digitally configurable

SELV equivalent Uout: 20 – 54 V

100’000 h lifetime at tc = 65°C

Output power up to 37 W

tc max = 75 °C

Mains voltage 220 – 240 V

Wide ta range -25 – +60 °C

Suitable for emergency lighting

5 years guarantee
1
Edition: 11 Feb. 2015
Ver.: 1.1
Status: Released
Misprints and technical changes excepted
OPTOTRONIC® LED Power Supply
OTi DALI 35/220-240/700 LT2 L
Product Data Sheet
ENVIRONMENT
DIMMING
OUTPUT
INPUT
Electrical Specifications
Item
Nominal voltage
Nominal frequency
AC voltage range
DC voltage range
Maximum voltage
Nominal current
Total Harmonic Distortion (THD)
Power factor
Efficiency
Power losses
No-load power
Stand-by power
Protection class
Inrush current
Max. units per circuit breaker
PE current
Nominal voltage range
Maximum voltage
Nominal current range
Current accuracy
Current ripple
Nominal power range
Maximum power
Galvanic isolation
Dimming control
Dimming range
Dimming technique
Frequency
Galvanic isolation
Ambient temperature range ta
Maximum case temperature tc
Max. case temp. in fault condition
Storage temperature range
Relative humidity
Surge transient protection
Environmental rating
IP rating
Mains switching cycles
Expected lifetime
Value
220 – 240
0 / 50 / 60
198 – 264
176 – 276
350
0.18
< 11
> 0.96
Up to 90%
4.5
n/a
< 500
I
32
B16: 30; B10: 18
< 0.5
20 – 54
60
200 – 700
+/- 2
100 Hz: zero
HF: 200
4 – 35
37
SELV equivalent
Yes
1 – 100
mixed
> 450
basic / double
-25 …+60
75
110
-25 …+85
5 ... 85
1|2
Indoor
IP 20
> 100’000
50’000
100’000
Unit
V
Hz
V
V
Vac
A
%
%
W
W
mW
A pk
mA
V
V
mA
%
%
mApk
W
W
%
Hz
°C
°C
°C
°C
%
kV
h
Remarks
Incl. DC or pulse DC
DC or pulse DC
2 h maximum, unit might not operate in this abnormal condition
Full load, steady operation
Full load, 220 – 240 V, 50 Hz / see graphs
Full load, 220 – 240 V, 50 Hz / see graphs
Full load, 220 – 240 V, 50 Hz / see graphs
Maximum, full load, steady operation
Load switching on output side is safe but not permitted
PE can be connected either to terminal or housing
Max, th = 100 μs 50%
I max = 32 A Th = 100 μs
Through PE, output floating
With smart power management to light up LED modules at -25°C
No load protection, restart trials every 2-3 s
LEDset open:100 mA; LEDset short: 700 mA
Maximum; initial accuracy < 1%
low freq. ripple is negligible
High frequency ripple is constant over the output current range
Dimmable down to 0.04W
Output and LEDset to mains - Touch current < 0.7 mA
DALI, TouchDIM with or without sensor, Corridor functionality
Of selected nominal current
1 – 26% PWM (Iout < 180 mA typ.), 27 – 100% amplitude dimming
1 – 26% PWM dimming
Basic DALI to primary-earth / Double DALI to secondary
Measured on tc point indicated of the product label
Not condensing
L/N | LN/PE acc to. EN 61547-5.7
tc = 75°C, 0.2% / 1’000 h failure rate
tc = 65°C, 0.1% / 1’000 h failure rate
Protections
Overtemperature, Overload, No load, Short-circuit, Input overvoltage, Output overvoltage, Output undervoltage
See remarks on page 4.
Wiring Diagram
Two or more units cannot be connected together on secondary side with any or more of the 21 … 27 terminals.
2
Edition: 11 Feb. 2015
Ver.: 1.1
Status: Released
Misprints and technical changes excepted
OPTOTRONIC® LED Power Supply
OTi DALI 35/220-240/700 LT2 L
Product Data Sheet
Configuring the output current and other functionalities
Selecting the output current
The OTi DALI 35/220-240/700 LT2 L allows the selection of the output current both through the LEDset Interface and digital programming with
Tuner4TRONIC® SW:

LEDset interface: connect a resistor to terminals 26 and 27. Select the resistor’s value using the following chart or Rset formula.
Note for terminals 26 and 27: open circuit  Iout = 100 mA; short circuit  Iout = 700 mA.
Check the LEDset application note for further details and suggestions: www.osram.com\ledset

Digital programming: power up the unit and connect the DALI terminals to the DALI magic (USB to DALI interface), use the
Tuner4TRONIC® SW (available only for OEMs upon registration on the myOSRAM portal).
For further information check: www.osram.com/t4t
Typical Iout vs Rset
Rset formula and standard Iout values
I OUT A  
5V
1000
Rset  
Iout [mA]
Iout [mA]
nominal
actual
Rset [kOhm]
E48 series
250
255
19.6
350
357
14.0
500
500
10.0
700
700
6.81
6.8 E24 series
Refer to the LEDset application note for further details.
Configuring the unit’s functionalities
All user configurable features of the OTi DALI 35/220-240/700 LT2 L can be adjusted using the Tuner4TRONIC® SW (available only for OEMs
upon registration on the myOSRAM portal) and the DALI magic. For further information check: www.osram.com/t4t
A subset of user configurable features and all DALI parameters can be configured using the DALI Wizard SW and DALI magic. For further
information check: www.osram.com/software.
Powering up the unit for programming
The unit must be powered up in order to enable the programming through the DALI terminals.
To improve the programming operator’s safety, in place of the mains voltage, only for programming purpose, the unit can be powered up using a
SELV 48 Vdc power supply, delivering the following performance:

Output voltage range: 48Vdc -7/+20 % (44.6 - 57.6 Vdc)

Output current: continuous 100 mA; inrush 1.5 A, 2 ms peak

Automatic restart from overload or short circuit
Suggested SELV power supply: OPTOTRONIC OTe 25/220-240/420 CS (use 420 mA output), with cable clamps accessory.
Important notice: OSRAM is not liable for possible wrong programming in case of use of external power supplies not compliant with
the above mentioned performance requirements.
3
Edition: 11 Feb. 2015
Ver.: 1.1
Status: Released
Misprints and technical changes excepted
OPTOTRONIC® LED Power Supply
OTi DALI 35/220-240/700 LT2 L
Product Data Sheet
Performance charts
Typical Operating window
Dimming
operating
area
Typical Efficiency vs load
Rated
operating
area
Typical Power factor vs load
Typical THD vs load
4
Edition: 11 Feb. 2015
Ver.: 1.1
Status: Released
Misprints and technical changes excepted
OPTOTRONIC® LED Power Supply
OTi DALI 35/220-240/700 LT2 L
Product Data Sheet
Remarks











All values have to be considered typical and measured (where applicable) in standard condition 25 °C ambient
temperature.
Input over voltage protection: mains up to 350 Vac, for two hours maximum, will not destroy both the unit and the load;
shut down of load might occur in this condition.
Output short circuit / undervoltage protection: shut down of load happens if Uout is below 20V (typ. 15V); the unit automatically
tries to switch on the load again every 2-3 s for 0.1 s delivering the selected nominal current.
Output overload protection: the unit automatically reduces the output current to keep the output power below about 37 W.
Output over voltage protection:
the unit automatically reduces the output current to keep the output voltage below 54 V; the output current is reduced down to
180 mA typ., then the load is switched OFF. The unit automatically tries to switch on the load again every 2-3 s for 0.1 s delivering
up to the selected nominal current.
No load operation: the unit automatically tries to switch on the load every 2-3 s for 0.1 s delivering the selected nominal current;
despite this operation mode is safe for both unit and load, it is not recommended. Do not put a switch between load and unit.
Over temperature protection: the unit is protected against temporary overheating by automatic reduction of the output current
when 75°C < tc < 95°C typ., and by automatic power off if 95°C < tc < 100° typ. The protection is self restoring.
Touch current: lower than 0.7 mA, according to EN 60598-1 ann. G and EN 61347-1 ann. A
Switchover time: lower than 0.5 s, both AC and DC mains.
Output power hold time: > 4 ms, in case of mains dips.
Emergency lighting: this LED power supply is suitable for emergency lighting fixtures acc. to EN 60598-2-22;
EOFI = 1% - 100% according to EN61347-2-13 ann J.
Standards
Ordering information
EN 61347-1
Product name
Type
EAN10
EAN40
NAED
EN 61347-2-13
OTi DALI 35/220-240/700 LT2 L
AA75167
4052899245389
4052899245396
n/a
Pieces / box
20
EN 55015
EN 61547
EN 61000-3-2
EN 62384
EN 62386
Manufacturer’s address:
Technical support:
OSRAM GmbH
Kunden Service Center Germany
+49 (0)89-6213-60 00
Steinerne Furt 62
D-86167 Augsburg
Germany