FSS - 1-Phase AC Filters / DC Filters

FSS
1-Phase AC Filters / DC Filters
www.schurter.com/PG84
AC Filter 2-Stage, Very High Symmetrical Attenuation
Description
-Chassis:
Screw-on mounting, from top
-Line-filter in standard version, 2 positions, very high attenuation, broadband
-Especially effective against symmetrical interferences in the frequency
range from 10kHz up to 30MHz
Approvals
-VDE Certificate Number: 40004673
-UL File Number: E72928
Characteristics
-Designed for increased requirements
-2-stage line filter with increased attenuation
Protection against interference voltage from the mains
Possible interferences generated in the equipment are strongly attenuated
-Especially suitable for use in switching power supplies
e.g. in electronic designs with high repetitive switching frequency
-Suitable for use in equipment according to IEC/UL 60950
References
Alternative: Standard version Weblinks
pdf-datasheet, html-datasheet, General Product Information, Approvals,
CE declaration of conformity, RoHS, CHINA-RoHS, REACH, e-Shop,
SCHURTER-Stock-Check, Distributor-Stock-Check, Detailed request for
product
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
Allowable Operation Temp.
Climatic Category
Protection Class
Terminal
Material: Housing
1 - 16 A @ Ta 40 °C / 250 VAC; 50 Hz
1 - 16 A @ Ta 40 °C / 125/250 VAC;
60 Hz
industrial < 1.4 mA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
-25 °C to 100 °C
25/100/21 acc. to IEC 60068-1
Suitable for appliances with protection
class I acc. to IEC 61140
Quick connect terminals 6.3 x 0.8 mm
or screw terminals
Aluminum
Line Filter
MTBF
Standard and Industrial Version, IEC
60939, UL 1283, CSA C22.2 no. 8
Technical Details
> 200'000 h acc. to MIL-HB-217 F
EMC Products
1
FSS
1-Phase AC Filters / DC Filters
www.schurter.com/PG84
Dimension
Case 10
Case 19
2)
101 ±0.8
1) Line
2) Load
Case 27
Case 48
max. 56
max. 151
(5)
(12)
max. 115
1) Line
2) Load
max. 173
(23)
1)
(11.5)
3.8 ±0.2
max. 49
(36)
(27)
max. 53
max. 41
(20)
48 ±0.3
max. 57
(26.5)
6.3x0.8
2)
1)
max. 112
max. 87
max. 33
max. 56
5.3x8.8
max. 81
91 max.
66 max.
1) Line
2) Load
1) Line
2) Load
Diagrams
Standard version
1)
2)
1) Line
2) Load
2
EMC Products
43 max.
(3.5)
(20)
(27)
2)
1)
75 ±0.3
6.5 ±0.3
85 ±0.3
6.3x0.8
5.3
51 max.
2)
max. 101
1)
111.5 ±0.5
max. 127
4 mm²
(12)
FSS
1-Phase AC Filters / DC Filters
www.schurter.com/PG84
Attenuation Loss
- - - - differential mode _____ common mode
Standard version
1A
2A
3A
6A
10 A
Industrial version
4A
Rated Current
[A]
Filter-Type
Leakage Current [mA]
L1
[mH]
L2
[mH]
L3
[mH]
16 A
Cx1 [μF] Cx2 [μF]
Cy1
[nF]
Cy2
[nF]
R [MΩ]
Weight
[g]
Housing
Order Number
1
Standard Version
0.25
2 x 15
1
-
0.1
0.47
1.5
1
1
121 g
10
5500.2051
2
Standard Version
0.25
2 x 10
0.4
0.4
0.1
0.47
1.5
1
1
121 g
10
5500.2052
3
Standard Version
0.25
2 x 12
1
-
0.1
0.68
1.5
1
1
275 g
48
5500.2053
4
Industrial Version
1.4
2 x 10
0.8
-
0.1
0.68
10
4.7
1
275 g
48
5500.2054
█
6
Industrial Version
1.4
2x6
0.5
-
0.1
0.68
10
4.7
1
284 g
48
5500.2055
█
10
Industrial Version
1.4
2x5
0.2
0.2
0.1
1
10
4.7
1
529 g
19
5500.2056
█
16
Industrial Version
1.4
2x4
0.2
0.2
0.47
2.2
10
4.7
1
2000 g
27
5500.2057
█ Most Popular.
Availability for all products can be searched real-time:http://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER
10 Pcs 08.04.2015
Packaging unit The specifications, descriptions and illustrations indicated in this document are based on current
information. All content is subject to modifications and amendments. Information furnished is believed
to be accurate and reliable. However, users should independently evaluate the suitability and test each
product selected for their own applications.
EMC Products