CMF3, CMF6 - Power entry modules without line filter

CMF3, CMF6
Power entry modules without line filter
www.schurter.com/PG05
IEC Appliance Inlet C6 with Line Switch 1-pole
CMF3
C6
70° C
Description
-Panel Mount:
Screw-on mounting on PCB, from top or bottom
-2 Functions:
Appliance Inlet Protection class I, Line Switch 1‑pole
-For PCB mounting
Characteristics
-Easy mounting with center bolt and snapper or srewed on PCB or
housing
-Electrical connection done on the PCB
-Bi-positioning of the switch from left or right side, Standard CMF with
switch on right side
-With or without rear-side insulation cover
-Suitable for use in equipment according to IEC/UL 60950
Other versions on request
-Line switch with other rocker marking
-Line switch on left of inlet
References
Alternative: protection class II version Weblinks
pdf-datasheet, html-datasheet, General Product Information, Approvals,
CE declaration of conformity, RoHS, CHINA-RoHS, REACH, Mating
Connectors, e-Shop, SCHURTER-Stock-Check, Distributor-StockCheck, CAD-Drawings, Accessories, Detailed request for product
Technical Data
Ratings IEC
Ratings UL/CSA
Dielectric Strength
Allowable Operation Temp.
Degree of Protection
Protection Class
Terminal
Material: Housing
2.5 A / 250 VAC; 50 Hz
6 A / 125 VAC; 60 Hz
> 2.3 kVAC between L-N
> 2.8 kVAC between L/N-PE
(1 min/50 Hz)
-25 °C to 70 °C
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class I acc. to IEC 61140
PCB 1.6 mm
Additional ground terminal
Thermoplastic, black, UL 94V-0
Appliance Inlet
Line Switch
C6 acc. to IEC 60320,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C,
2.5 A, Protection Class I
Rocker switch 1-pole, non-illuminated,
acc. to IEC 61058-1
Technical Details
Connectors
1
CMF3, CMF6
Power entry modules without line filter
www.schurter.com/PG05
Dimensions
24.3
53.3
2.3
26.65
22.3
2.3
26.65
0.9
2
3
19
R
1
27.3
9
1.6
4
4
6.75
2.8
4.5
14.15
R
1.05
10
3 -0.1
9.5
7
2.4
1.3
8.15
8.25
5
2.1
0
0.8
0.8
3.8 8
4.15
45 ±0.1
27.55
11
3
25.75
10
With insulation cover
The size of the mounting cut-out can be selected as required.
Drilling Diagram / CMF3 (C6)
Fixation on PCB or housing from
below
Fixation on PCB or housing from
above
9.7
8.25 7
+0.1
0
1)
M3x12
21.6
4.2±0.05
13.4
1.6
3.2
0
5.9- 0.1
9
9 ±0.1
10
3
D1
23.4
1) self tapping screw
45±0.1
28.05
1)
M3x12
11±0.13
3
9.5
5
5
11
3.81
1.6
3
+0.30
11 +0.15
14.3
+0.1
1.6 0
13
10
1) self tapping screw
29.85
D1 = 6.2 mm mounting from above / D1 = 3.6 mm mounting from below
PC Board 1.6 mm / Dimensions without tolerance: ≤ 15 = ± 0.05 / > 15 = ± 0.10
Drilling diagram CMF6 mirror-inverted
All Variants
Connectors
Mounting side
Cover
C6
from below
with cover
C6
from below
with cover
C6
from below
with cover
C6
from below
Ground terminal
Ground terminal direction
Order Number
-
-
CMF3.1132.12
Solder terminal 2.8 x 0.8 mm
angled to pin axis
CMF3.1133.12
Solder terminal 2.8 x 0.8 mm
straight
CMF3.1134.12
without cover
-
-
CMF3.1032.12
C6
from below
without cover
Solder terminal 2.8 x 0.8 mm
angled to pin axis
CMF3.1033.12
C6
from below
without cover
Solder terminal 2.8 x 0.8 mm
straight
CMF3.1034.12
C6
from top
with cover
-
-
CMF3.1112.12
C6
from top
with cover
Solder terminal 2.8 x 0.8 mm
angled to pin axis
CMF3.1113.12
C6
from top
with cover
Solder terminal 2.8 x 0.8 mm
straight
CMF3.1114.12
2
Connectors
CMF3, CMF6
Power entry modules without line filter
www.schurter.com/PG05
Connectors
Mounting side
Cover
Ground terminal
Ground terminal direction
Order Number
C6
from top
without cover
C6
from top
without cover
-
-
CMF3.1012.12
Solder terminal 2.8 x 0.8 mm
angled to pin axis
C6
from top
without cover
Solder terminal 2.8 x 0.8 mm
CMF3.1013.12
straight
CMF3.1014.12
Availability for all products can be searched real-time:http://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER
50 Pcs 24.08.2015
Packaging unit The specifications, descriptions and illustrations indicated in this document are based on current
information. All content is subject to modifications and amendments. Information furnished is believed
to be accurate and reliable. However, users should independently evaluate the suitability and test each
product selected for their own applications.
Connectors
3