typ 6052.0043

6052.0043
Cord Sets
www.schurter.com/PG07_2
US Power Supply Cord with IEC Connector C5, straight
C5
NEMA 5-15
70°C
Description
-1 Function:
-Power Cord, -Protection class I
-Pin temperature 70 °C
-custom specific versions on request
Technical Data
Ratings UL/CSA
Allowable Operation Temp.
Degree of Protection
Protection Class
7 A / 125 VAC; 50/60 Hz
-40 °C to 70 °C
IP 40 acc. to
Suitable for appliances with protection
class I acc. to IEC 61140
PVC, black
Material: Housing
Connector
C5 acc. to IEC 60320-1
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 7 A,
Protection Class I
All Variants
Connector
cable
Type
Cord Type
Conductor cross
section
Length [m]
Color
Type
SVT 3x18
AWG
3 x 18 AWG
1.8
black
North America USA
V-Lock
C5
Plug
Country Standard
NEMA 5-15
Order Number
Style
Index
straight
-
6052.0043
█ Most Popular.
Availability for all products can be searched real-time:http://www.schurter.com/Stock-Check/Stock-Check-SCHURTER
Packaging unit 50 Pcs Mating Inlets/Plugs
Category / Description
Appliance Inlet Overview complete
IEC Appliance Inlet C6, Screw-on Mounting, Front Side, Solder Terminal or Solder Terminal for PCB
0724
IEC Appliance Inlet C6, Screw-on Mounting, Front or Rear Side, Solder, PCB or Quick-connect Terminal
2561
IEC Appliance Inlet C6, Screw-on Mounting, Front or Rear Side, Solder, PCB or Quick-connect Terminal
2562
IEC Appliance Inlet C6, insert Mounting, Front or Rear Side, Solder, PCB or Quick-connect Terminal
2563
IEC Appliance Inlet C6, Snap-in Mounting, Front Side, Solder or Quick-connect Terminal
2565
Appliance Inlet further types to 6052.0043
Connectors
1
█
6052.0043
Cord Sets
www.schurter.com/PG07_2
Power Entry Module Overview complete
IEC Appliance Inlet C6 with Line Switch 1-pole
CMF3, CMF6
Power Entry Module further types to 6052.0043
10.06.2016
2
Connectors
The specifications, descriptions and illustrations indicated in this document are based on current
information. All content is subject to modifications and amendments. Information furnished is believed
to be accurate and reliable. However, users should independently evaluate the suitability and test each
product selected for their own applications.