Felcom 54 Power Entry Modules with Line Filter www.schurter.com/PG06 IEC Appliance Inlet C14 Modular Assembling Options Snap-In Version Standard- or Medical-Filter 5411.XX5X.XXX Appliance inlet Fuseholder Line filter C14 F 70° C 70° C Description -Panel Mount: Snap-in version from front side -2 - 5 Functions: Appliance Inlet Protection class I, Connector, Line Switch 2-pole, Fuseholder for fuse-links 5 x 20 mm 1‑ or 2‑pole, Line filter in standard and medical version -Solder terminals 3.5 x 0.8 mm or quick connect terminals 6.3 x 0.8 mm 5431.X05X.XXX Appliance inlet Appliance outlet Switch Line filter Characteristics -Modular component selection -Individual components soldered on a printed circuit board -Plug removal necessary for fuse-link replacement -Technical data of filter-components see blockfilter type 5500 -Fully insulated from the rear -Suitable for use in equipment according to IEC/UL 60950 Suitable for use in medical equipment according to IEC/UL 60601-1 Other versions on request -Line switch with other rocker marking Approvals -VDE Certificate Number: 101307 -UL File Number: E72928 References Alternative: version without line filter Felcom 64 Alternative: Standard version Weblinks pdf-datasheet, html-datasheet, General Product Information, Approvals, CE declaration of conformity, RoHS, CHINA-RoHS, REACH, Mating Connectors, e-Shop, SCHURTER-Stock-Check, Distributor-StockCheck, CAD-Drawings, Accessories, Detailed request for product Technical Data Ratings IEC Ratings UL/CSA Leakage Current Dielectric Strength Allowable Operation Temp. Climatic Category Degree of Protection Protection Class Terminal Panel Thickness s Material: Housing 1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz 1 - 10 A @ Ta 40 °C / 250 VAC; 60 Hz standard < 0.5 mA (250 V / 60 Hz) medical < 5 µA (250 V / 60 Hz) > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (2 sec) -25 °C to 85 °C 25/085/21 acc. to IEC 60068-1 from front side IP 40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Solder terminals 3.5 x 0.8 mm or quick connect terminals 6.3 x 0.8 mm Snap-in: 1/1.2/1.5/2/2.5/3 mm1/1.2/1.5 /2/2.5/3 mm Thermoplastic, black, UL 94V-0 Appliance-Inlet/-Outlet Fuseholder Rated Power Acceptance @ Ta 23 °C Power Acceptance @ Ta > 23°C Line Switch Line Filter MTBF C14 acc. to IEC 60320, F acc. to IEC 60320, UL 498, CSA C22.2 no. 42 (for cold conditions) pin-temperature 70 °C, 10 A, Protection Class I 1 or 2 pole, Shocksafe category PC2 acc. to IEC 60127-6, for fuse-links 5 x 20 mm 5 x 20: 2 W (1 pole)/ 1.6 W (2-pole) per pole Admissible power acceptance at higher ambient temperature see derating curves Rocker switch 2-pole, non-illuminated, acc. to IEC 61058-1 Technical Details Standard Version, IEC 60939, UL 1283, CSA C22.2 no. 8 Technical Details > 1'400'000 h acc. to MIL-HB-217 F Connectors 1 Felcom 54 Power Entry Modules with Line Filter www.schurter.com/PG06 Dimension 85.8 1) 89.3 1) 10 Variants 5423.XX5X.XXX Mounting hole: 96.4+0,2 x 27.6+0,2 A: Quick-connect terminal 6.3x0.8 mm: 22 mm A: Solder terminal 3.5x0.8 mm: 17.5 mm 10 +0.30 0 Variants 5424.XX5X.XXX Mounting hole: 87.9+0,2 x 27.6+0,2 A: Quick-connect terminal 6.3x0.8 mm: 22 mm A: Solder terminal 3.5x0.8 mm: 17.5 mm 111.0 1) A 10 30 10 +0.30 0 30 10 +0.30 0 10 Variants 5421.X05X.XXX Mounting hole: 85.9+0,2 x 27.6+0,2 A: Quick-connect terminal 6.3x0.8 mm: 22 mm A: Solder terminal 3.5x0.8 mm: 17.5 mm A 30 10 +0.30 0 Variants 5411.XX5X.XXX Mounting hole: 63 +0.2 x 27,6 +0.2 A: Quick-connect terminal 6.3x0.8 mm: 22 mm A: Solder terminal 3.5x0.8 mm: 17.5 mm 96.3 1) A 30 10 30 10 +0.30 0 A 10 64.2 1) Variants 5431.X05X.XXX Mounting hole: 111.1+0,2 x 27.6+0,2 A: Quick-connect terminal 6.3x0.8 mm: 22 mm A: Solder terminal 3.5x0.8 mm: 17.5 mm 1) In an uninstalled state the total length of the combinations may be slightly bigger than the nominal dimension. However, they can always be installed in the specified mounting cutouts. 2 Connectors Felcom 54 23 23 +0.50 0 +0.50 0 5.5 3 ±0.20 +0.30 0 Power Entry Modules with Line Filter www.schurter.com/PG06 121.5 1) S 12 +0.30 0 10 30 10 +0.30 0 A Variants 5432.XX5X.XXX Mounting hole: 121.6+0,2 x 27.6+0,2 A: Quick-connect terminal 6.3x0.8 mm: 22 mm A: Solder terminal 3.5x0.8 mm: 17.5 mm 1) In an uninstalled state the total length of the combinations may be slightly bigger than the nominal dimension. However, they can always be installed in the specified mounting cutouts. Technical Data of Filter-Components Rated Current [A] Filter-Type Inductances L [mH] Capacitance CX [nF] Capacitance CY [nF] R [MΩ] 1 Standard Version 2 x 11 47 2.2 - 2 Standard Version 2x4 47 2.2 - 4 Standard Version 2 x 1.6 47 2.2 - 6 Standard Version 2 x 0.7 47 2.2 - 8 Standard Version 2 x 0.6 47 2.2 - 10 Standard Version 2 x 0.4 47 2.2 - 1 Medical Version (M5) 2 x 11 47 - 1 2 Medical Version (M5) 2x4 47 - 1 4 Medical Version (M5) 2 x 1.6 47 - 1 6 Medical Version (M5) 2 x 0.7 47 - 1 8 Medical Version (M5) 2 x 0.6 47 - 1 10 Medical Version (M5) 2 x 0.4 47 - 1 Connectors 3 Felcom 54 Power Entry Modules with Line Filter www.schurter.com/PG06 Diagrams 5411 5421 L 1) LINE N 2) Cx 1) Cy 2) Cx Cy Cy 1) Line 2) Load 1 1) Load 2 2) Load 1 5423 5424 L LINE N 1) 1) 2) Cx 2) Cx Cy Cy 1) Line 2) Load 1 5431 5432 LINE N L 1) 2) Cx Cy 1) Load 2 2) Load 1 Admissible power acceptance in Watt 1.5 I = 1.0 In I = 0.7 In 1.0 I = << In 0.5 0.0 0 20 40 60 80 100 Ambient air temperature Ta °C Admissible power acceptance in Watt 2-pole 2.0 1.6 1.4 1.2 I = 1.0 In 1.0 0.8 I = 0.7 In 0.6 I = << In 0.4 0.2 0.0 0 20 40 60 80 100 Ambient air temperature Ta °C Connectors LINE N 2) Cx Cy Derating Curves 4 1) Cy 1) Load 2 2) Load 1 1-pole Cy Cy 1) Load 2 2) Load 1 L Cy Cy Felcom 54 Power Entry Modules with Line Filter www.schurter.com/PG06 Ordering instructions 54 XX. X X XX. XX X Type of line filter 1 = standard 3 = medical “Snap-in” panel thickness 10 = 1,0 mm 12 = 1,2 mm 15 = 1,5 mm 20 = 2,0 mm 25 = 2,5 mm 30 = 3,0 mm Connection 51 = solder terminals 3,5 x 0,8 mm 53 = quick connect terminals 6,3 x 0,8 mm Fuseholder 5 x 20 mm 0 = without fuseholder 1 = 1-pole 2 = 2-pole Line filter 1 = 1 Amp. 2 = 2 Amp. 4 = 4 Amp. 6 = 6 Amp. 8 = 8 Amp. 9 = 10 Amp. Module combination 11 = Appliance inlet, fuseholder 21 = Appliance inlet, appliance outlet 23 = Appliance inlet, fuseholder, appliance outlet 24 = Appliance inlet, fuseholder, switch 31 = Appliance inlet, appliance outlet, switch 32 = Appliance inlet, fuseholder, appliance outlet, switch Base model All Variants Type Rated Current [A] Filter-Type Panel Thickness s [mm] connection type Line Switch Fuseholder Connectors Connector Order Number Felcom 54 1 Standard Version 3.0 Solder terminals 3.5 x 0.8 mm 2-pole 1-pole C14 - 5424.1151.301 Felcom 54 1 Standard Version 3.0 Quick connect terminals 6.3 x 0.8 mm 2-pole 1-pole C14 - 5424.1153.301 Felcom 54 1 Standard Version 2.0 Quick connect terminals 6.3 x 0.8 mm 2-pole 2-pole C14 - 5424.1253.201 Felcom 54 1 Medical Version (M5) 3.0 Quick connect terminals 6.3 x 0.8 mm 2-pole 2-pole C14 - 5424.1253.303 Felcom 54 2 Standard Version 2.5 Quick connect terminals 6.3 x 0.8 mm 2-pole 2-pole C14 - 5424.2253.251 Felcom 54 2 Standard Version 3.0 Quick connect terminals 6.3 x 0.8 mm 2-pole 2-pole C14 F 5432.2253.301 Felcom 54 2 Medical Version (M5) 1.5 Quick connect terminals 6.3 x 0.8 mm - 2-pole C14 - 5411.2253.151 Felcom 54 2 Medical Version (M5) 1.5 Quick connect terminals 6.3 x 0.8 mm 2-pole 2-pole C14 - 5424.2253.153 Felcom 54 4 Standard Version 1.5 Quick connect terminals 6.3 x 0.8 mm - 2-pole C14 - 5411.4253.151 Felcom 54 4 Standard Version 1.5 Quick connect terminals 6.3 x 0.8 mm 2-pole 2-pole C14 - 5424.4253.151 Felcom 54 4 Standard Version 2.0 Solder terminals 3.5 x 0.8 mm 2-pole 2-pole C14 F 5432.4251.201 Felcom 54 4 Standard Version 2.0 Quick connect terminals 6.3 x 0.8 mm 2-pole 2-pole C14 F 5432.4253.201 Felcom 54 4 Medical Version (M5) 1.0 Quick connect terminals 6.3 x 0.8 mm - 2-pole C14 - 5411.4253.103 Felcom 54 4 Medical Version (M5) 1.5 Quick connect terminals 6.3 x 0.8 mm 2-pole 2-pole C14 - 5424.4253.153 Felcom 54 4 Medical Version (M5) 3.0 Quick connect terminals 6.3 x 0.8 mm 2-pole 2-pole C14 - 5424.4253.303 Availability for all products can be searched real-time:http://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER Packaging unit 10 Pcs Connectors 5 Felcom 54 Power Entry Modules with Line Filter www.schurter.com/PG06 Accessories Description Cord retaining kits Cord retaining strain relief Flat head, A 4700.0001 Mating Inlets/Plugs Category / Description Plug Overview complete IEC Plug E, Cord Connector (Rewireable), Straight, max. cable Diameter 8.5 mm 4732 IEC Plug E, Cord Connector (Rewireable), Straight, max. Cable Diameter 10 mm 4735 IEC Plug E, Cord Connector (Rewireable), Straight 9009 IEC Plug E, Cord Connector (Rewireable), Angled, max. Cable Diameter 8.5 mm 4733 IEC Plug E, Cord Connector (Rewireable), Angled, max. Cable Diameter 10 mm 4736 Plug further types to Felcom 54 ... Mating Outlets/Connectors Appliance Outlet Overview complete IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder Terminal 4787 IEC Appliance Outlet F, Snap-in Mounting, Front Side, Solder or Quick-connect Terminal 4788 IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal 5091 Appliance Outlet further types to Felcom 54 Connector Overview complete 4782 4022 Mounting: Power Supply Cord, 3 x 1.5 mm², Screw clamps, Connector: IEC C13 4022 4785 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4785 4300-06 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4300-06 4012 Mounting: Power Supply Cord, 3 x 1.5 mm², Screw clamps, Connector: IEC C13 4012 Connector further types to Felcom 54 ... 24.08.2015 4782 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 6 Connectors The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments. Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability and test each product selected for their own applications.