Felcom 54 - Power Entry Modules with Line Filter

Felcom 54
Power Entry Modules with Line Filter
www.schurter.com/PG06
IEC Appliance Inlet C14 Modular Assembling Options
Snap-In Version
Standard- or Medical-Filter
5411.XX5X.XXX
Appliance inlet
Fuseholder
Line filter
C14
F
70° C
70° C
Description
-Panel Mount:
Snap-in version from front side
-2 - 5 Functions:
Appliance Inlet Protection class I, Connector, Line Switch 2-pole, Fuseholder for fuse-links 5 x 20 mm 1‑ or 2‑pole, Line filter in standard
and medical version
-Solder terminals 3.5 x 0.8 mm or quick connect terminals 6.3 x 0.8
mm
5431.X05X.XXX
Appliance inlet
Appliance outlet
Switch
Line filter
Characteristics
-Modular component selection
-Individual components soldered on a printed circuit board
-Plug removal necessary for fuse-link replacement
-Technical data of filter-components see blockfilter type 5500
-Fully insulated from the rear
-Suitable for use in equipment according to IEC/UL 60950
Suitable for use in medical equipment according to IEC/UL 60601-1
Other versions on request
-Line switch with other rocker marking
Approvals
-VDE Certificate Number: 101307
-UL File Number: E72928
References
Alternative: version without line filter Felcom 64 Alternative: Standard version Weblinks
pdf-datasheet, html-datasheet, General Product Information, Approvals,
CE declaration of conformity, RoHS, CHINA-RoHS, REACH, Mating
Connectors, e-Shop, SCHURTER-Stock-Check, Distributor-StockCheck, CAD-Drawings, Accessories, Detailed request for product
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
Allowable Operation Temp.
Climatic Category
Degree of Protection
Protection Class
Terminal
Panel Thickness s
Material: Housing
1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz
1 - 10 A @ Ta 40 °C / 250 VAC; 60 Hz
standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
-25 °C to 85 °C
25/085/21 acc. to IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class I acc. to IEC 61140
Solder terminals 3.5 x 0.8 mm or quick
connect terminals 6.3 x 0.8 mm
Snap-in: 1/1.2/1.5/2/2.5/3 mm1/1.2/1.5
/2/2.5/3 mm
Thermoplastic, black, UL 94V-0
Appliance-Inlet/-Outlet
Fuseholder
Rated Power Acceptance @
Ta 23 °C
Power Acceptance @ Ta >
23°C
Line Switch
Line Filter
MTBF
C14 acc. to IEC 60320,
F acc. to IEC 60320,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection Class I
1 or 2 pole, Shocksafe category PC2
acc. to IEC 60127-6,
for fuse-links 5 x 20 mm
5 x 20: 2 W (1 pole)/ 1.6 W (2-pole) per
pole
Admissible power acceptance at higher
ambient temperature see derating curves
Rocker switch 2-pole, non-illuminated,
acc. to IEC 61058-1
Technical Details
Standard Version, IEC 60939, UL 1283,
CSA C22.2 no. 8
Technical Details
> 1'400'000 h acc. to MIL-HB-217 F
Connectors
1
Felcom 54
Power Entry Modules with Line Filter
www.schurter.com/PG06
Dimension
85.8 1)
89.3 1)
10
Variants 5423.XX5X.XXX
Mounting hole: 96.4+0,2 x 27.6+0,2
A: Quick-connect terminal 6.3x0.8 mm: 22 mm
A: Solder terminal 3.5x0.8 mm: 17.5 mm
10
+0.30
0
Variants 5424.XX5X.XXX
Mounting hole: 87.9+0,2 x 27.6+0,2
A: Quick-connect terminal 6.3x0.8 mm: 22 mm
A: Solder terminal 3.5x0.8 mm: 17.5 mm
111.0 1)
A
10
30
10
+0.30
0
30
10
+0.30
0
10
Variants 5421.X05X.XXX
Mounting hole: 85.9+0,2 x 27.6+0,2
A: Quick-connect terminal 6.3x0.8 mm: 22 mm
A: Solder terminal 3.5x0.8 mm: 17.5 mm
A
30
10
+0.30
0
Variants 5411.XX5X.XXX
Mounting hole: 63 +0.2 x 27,6 +0.2
A: Quick-connect terminal 6.3x0.8 mm: 22 mm
A: Solder terminal 3.5x0.8 mm: 17.5 mm
96.3 1)
A
30
10
30
10
+0.30
0
A
10
64.2 1)
Variants 5431.X05X.XXX
Mounting hole: 111.1+0,2 x 27.6+0,2
A: Quick-connect terminal 6.3x0.8 mm: 22 mm
A: Solder terminal 3.5x0.8 mm: 17.5 mm
1) In an uninstalled state the total length of the combinations may be slightly bigger than the nominal dimension. However, they can always be installed in the specified
mounting cutouts.
2
Connectors
Felcom 54
23
23
+0.50
0
+0.50
0
5.5
3 ±0.20
+0.30
0
Power Entry Modules with Line Filter
www.schurter.com/PG06
121.5 1)
S
12
+0.30
0
10
30
10
+0.30
0
A
Variants 5432.XX5X.XXX
Mounting hole: 121.6+0,2 x 27.6+0,2
A: Quick-connect terminal 6.3x0.8 mm: 22 mm
A: Solder terminal 3.5x0.8 mm: 17.5 mm
1) In an uninstalled state the total length of the combinations may be slightly bigger than the nominal dimension. However, they can always be installed in the specified
mounting cutouts.
Technical Data of Filter-Components
Rated Current
[A]
Filter-Type
Inductances
L [mH]
Capacitance
CX [nF]
Capacitance
CY [nF]
R [MΩ]
1
Standard Version
2 x 11
47
2.2
-
2
Standard Version
2x4
47
2.2
-
4
Standard Version
2 x 1.6
47
2.2
-
6
Standard Version
2 x 0.7
47
2.2
-
8
Standard Version
2 x 0.6
47
2.2
-
10
Standard Version
2 x 0.4
47
2.2
-
1
Medical Version (M5)
2 x 11
47
-
1
2
Medical Version (M5)
2x4
47
-
1
4
Medical Version (M5)
2 x 1.6
47
-
1
6
Medical Version (M5)
2 x 0.7
47
-
1
8
Medical Version (M5)
2 x 0.6
47
-
1
10
Medical Version (M5)
2 x 0.4
47
-
1
Connectors
3
Felcom 54
Power Entry Modules with Line Filter
www.schurter.com/PG06
Diagrams
5411
5421
L
1)
LINE
N
2)
Cx
1)
Cy
2)
Cx
Cy
Cy
1) Line
2) Load 1
1) Load 2
2) Load 1
5423
5424
L
LINE
N
1)
1)
2)
Cx
2)
Cx
Cy
Cy
1) Line
2) Load 1
5431
5432
LINE
N
L
1)
2)
Cx
Cy
1) Load 2
2) Load 1
Admissible power
acceptance in Watt
1.5
I = 1.0 In
I = 0.7 In
1.0
I = << In
0.5
0.0
0
20
40
60
80
100
Ambient air temperature Ta °C
Admissible power
acceptance in Watt
2-pole
2.0
1.6
1.4
1.2
I = 1.0 In
1.0
0.8
I = 0.7 In
0.6
I = << In
0.4
0.2
0.0
0
20
40
60
80
100
Ambient air temperature Ta °C
Connectors
LINE
N
2)
Cx
Cy
Derating Curves
4
1)
Cy
1) Load 2
2) Load 1
1-pole
Cy
Cy
1) Load 2
2) Load 1
L
Cy
Cy
Felcom 54
Power Entry Modules with Line Filter
www.schurter.com/PG06
Ordering instructions
54 XX. X X XX. XX X
Type of line filter
1 = standard
3 = medical
“Snap-in” panel thickness
10 = 1,0 mm
12 = 1,2 mm
15 = 1,5 mm
20 = 2,0 mm
25 = 2,5 mm
30 = 3,0 mm
Connection
51 = solder terminals 3,5 x 0,8 mm
53 = quick connect terminals 6,3 x 0,8 mm
Fuseholder 5 x 20 mm
0 = without fuseholder
1 = 1-pole
2 = 2-pole
Line filter
1 = 1 Amp.
2 = 2 Amp.
4 = 4 Amp.
6 = 6 Amp.
8 = 8 Amp.
9 = 10 Amp.
Module combination
11 = Appliance inlet, fuseholder
21 = Appliance inlet, appliance outlet
23 = Appliance inlet, fuseholder, appliance outlet
24 = Appliance inlet, fuseholder, switch
31 = Appliance inlet, appliance outlet, switch
32 = Appliance inlet, fuseholder, appliance outlet, switch
Base model
All Variants
Type
Rated Current [A]
Filter-Type
Panel Thickness s [mm]
connection type
Line Switch
Fuseholder
Connectors
Connector
Order Number
Felcom 54
1
Standard Version
3.0
Solder terminals 3.5 x 0.8 mm
2-pole
1-pole
C14
-
5424.1151.301
Felcom 54
1
Standard Version
3.0
Quick connect terminals 6.3 x 0.8 mm
2-pole
1-pole
C14
-
5424.1153.301
Felcom 54
1
Standard Version
2.0
Quick connect terminals 6.3 x 0.8 mm
2-pole
2-pole
C14
-
5424.1253.201
Felcom 54
1
Medical Version
(M5)
3.0
Quick connect terminals 6.3 x 0.8 mm
2-pole
2-pole
C14
-
5424.1253.303
Felcom 54
2
Standard Version
2.5
Quick connect terminals 6.3 x 0.8 mm
2-pole
2-pole
C14
-
5424.2253.251
Felcom 54
2
Standard Version
3.0
Quick connect terminals 6.3 x 0.8 mm
2-pole
2-pole
C14
F
5432.2253.301
Felcom 54
2
Medical Version
(M5)
1.5
Quick connect terminals 6.3 x 0.8 mm
-
2-pole
C14
-
5411.2253.151
Felcom 54
2
Medical Version
(M5)
1.5
Quick connect terminals 6.3 x 0.8 mm
2-pole
2-pole
C14
-
5424.2253.153
Felcom 54
4
Standard Version
1.5
Quick connect terminals 6.3 x 0.8 mm
-
2-pole
C14
-
5411.4253.151
Felcom 54
4
Standard Version
1.5
Quick connect terminals 6.3 x 0.8 mm
2-pole
2-pole
C14
-
5424.4253.151
Felcom 54
4
Standard Version
2.0
Solder terminals 3.5 x 0.8 mm
2-pole
2-pole
C14
F
5432.4251.201
Felcom 54
4
Standard Version
2.0
Quick connect terminals 6.3 x 0.8 mm
2-pole
2-pole
C14
F
5432.4253.201
Felcom 54
4
Medical Version
(M5)
1.0
Quick connect terminals 6.3 x 0.8 mm
-
2-pole
C14
-
5411.4253.103
Felcom 54
4
Medical Version
(M5)
1.5
Quick connect terminals 6.3 x 0.8 mm
2-pole
2-pole
C14
-
5424.4253.153
Felcom 54
4
Medical Version
(M5)
3.0
Quick connect terminals 6.3 x 0.8 mm
2-pole
2-pole
C14
-
5424.4253.303
Availability for all products can be searched real-time:http://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER
Packaging unit 10 Pcs Connectors
5
Felcom 54
Power Entry Modules with Line Filter
www.schurter.com/PG06
Accessories
Description
Cord retaining kits
Cord retaining strain relief
Flat head, A
4700.0001
Mating Inlets/Plugs
Category / Description
Plug Overview complete
IEC Plug E, Cord Connector (Rewireable), Straight, max. cable Diameter 8.5 mm
4732
IEC Plug E, Cord Connector (Rewireable), Straight, max. Cable Diameter 10 mm
4735
IEC Plug E, Cord Connector (Rewireable), Straight
9009
IEC Plug E, Cord Connector (Rewireable), Angled, max. Cable Diameter 8.5 mm
4733
IEC Plug E, Cord Connector (Rewireable), Angled, max. Cable Diameter 10 mm
4736
Plug further types to Felcom 54
...
Mating Outlets/Connectors
Appliance Outlet Overview complete
IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder Terminal
4787
IEC Appliance Outlet F, Snap-in Mounting, Front Side, Solder or Quick-connect Terminal
4788
IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal
5091
Appliance Outlet further types to Felcom 54
Connector Overview complete
4782
4022 Mounting: Power Supply Cord, 3 x 1.5 mm², Screw clamps, Connector: IEC C13
4022
4785 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13
4785
4300-06 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13
4300-06
4012 Mounting: Power Supply Cord, 3 x 1.5 mm², Screw clamps, Connector: IEC C13
4012
Connector further types to Felcom 54
...
24.08.2015
4782 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13
6
Connectors
The specifications, descriptions and illustrations indicated in this document are based on current
information. All content is subject to modifications and amendments. Information furnished is believed
to be accurate and reliable. However, users should independently evaluate the suitability and test each
product selected for their own applications.