Chip tantalum capacitors (Bottom surface electrode type) TCT Series U Case Features (U) Dimensions (Unit : mm) 1) Ultra-compact package 60% smaller footprint and 70% smaller volume than our conventional 1608(0603)-sized TCM series capacitors. 2) High capacitance : 1.0F to 4.7F ( 15F Under development ) Ideal for coupling and noise reduction in audio circuits 3) High productivity, high reliability Featuring the popular underside electrode configuration 4) Environmentally friendly halogen-free package Anode mark W1 L H W2 S (Unit : mm) Dimensions U case L 0.2 1.0 + −0 W1 0.2 0.5 + −0 W2 0.35 ± 0.1 H 0.6 Max. S 0.35 ± 0.1 S Part No. Explanation T C T U 0 G 1 2 3 4 7 5 M 8 R 5 6 4 4 Nominal capacitance 1 Series name Nominal capacitance in pF in 3 digits: 2 significant figures followed by the figure representing the number of 0's. TCT 2 Case style U 5 Capacitance tolerance M: + − 20% 3 Rated voltage Rated voltage (V) CODE 2.5 4 6.3 10 16 0E 0G 0J 1A 1C 6 Taping 8 : Reel width : 8mm R : Positive electrode on the side opposite to sprocket hole Rated table (μF) Rated voltage (V,DC) 2.5 4 6.3 16 ∗U U 1.0 (105) ∗U 1.5 (155) 2.2 (225) U ∗U ∗U 3.3 (335) 4.7 (475) U ∗U 6.8 (685) ∗U ∗U ∗U ∗U 10 (106) 15 (156) 10 ∗U 22 (226) Remark) Case size codes (U) in the above show products line-up. ∗ Under development www.rohm.com c 2011 ROHM Co., Ltd. All rights reserved. ○ 1/5 2011.12 - Rev.E TCT Series U Case Data Sheet Marking The indications listed below should be given on the surface of a capacitor. : The polarity should be shown by bar. (on the anode side) (1) Polarity (2) Rated DC voltage : Due to the small size of U case, a voltage code is used as shown below. (3) Visual typical example (1) voltage code (2) capacitance code Voltage Code Rated DC Voltage (V) Capacitance Code Nominal Capacitance (μF) e 2.5 A 1.0 g 4 E 1.5 j 6.3 J 2.2 A 10 N 3.3 C 16 S 4.7 W 6.8 [U case] note 1) a 10 e 15 g S − − (1) (2) gS manufacture code note 2) voltage code and capacitance code are variable with parts number Characteristics Performance Item Operating Temperature −55°C to +125°C Maximum operating temperature with no voltage derating +85°C Test conditions (based on JIS C 5101−1 and JIS C 5101−3) Voltage reduction when temperature exceeds +85°C Rated voltage (VDC) 2.5 4 6.3 10 16 at 85°C Category voltage (VDC) 1.6 2.5 4 6.3 10 at 125°C Surge voltage (VDC) 3.2 5.0 8 13 20 at 85°C DC Leakage current Shall be satisfied the voltage on " Standard list " As per 4.9 JIS C 5101-1 As per 4.5.1 JIS C 5101-3 Voltage : Rated voltage for 5min Capacitance tolerance Shall be satisfied allowance range. ±20% As per 4.7 JIS C 5101-1 As per 4.5.2 JIS C 5101-3 Measuring frequency : 120±12Hz Measuring voltage : 0.5Vrms +1.5 to 2V.DC : DC Equivalent series circuit Measuring circuit Tangent of loss angle (Df, tan δ) Shall be satisfied the voltage on " Standard list " As per 4.8 JIS C 5101-1 As per 4.5.3 JIS C 5101-3 Measuring frequency : 120±12Hz Measuring voltage : 0.5Vrms +1.5 to 2V.DC : DC Equivalent series circuit Measuring circuit Impedance Shall be satisfied the voltage on " Standard list " As per 4.10 JIS C 5101-1 As per 4.5.4 JIS C 5101-3 Measuring frequency : 100±10kHz Measuring voltage : 0.5Vrms or less : DC Equivalent series circuit Measuring circuit www.rohm.com c 2011 ROHM Co., Ltd. All rights reserved. ○ 2/5 2011.12 - Rev.E TCT Series U Case Performance Item Resistance to Soldering heat Temperature cycle Data Sheet Appearance There should be no significant abnormality. The indications should be clear. L.C. Less than 200% of initial limit ΔC / C Within +20/-30% of initial value Df (tan δ) Less than 200% of initial limit Appearance There should be no significant abnormality. The indications should be clear. L.C. Less than 200% of initial limit ΔC / C Within ±30% of initial value Df (tan δ) Less than 200% of initial limit Test conditions (based on JIS C 5101−1 and JIS C 5101−3) As per 4.14 JIS C 5101-1 As per 4.6 JIS C 5101-3 Dip in the solder bath Solder temp : 260±5°C Duration : 5±0.5s Repetition :1 After the specimens, leave it at room temperature for over 24h and then measure the sample. As per 4.16 JIS C 5101-1 As per 4.10 JIS C 5101-3 Repetition : 5 cycles (1 cycle : steps 1 to 4) without discontinuation. Temp. Time 1 −55 + − 3°C 30±3min. 2 Room temp. 125 + − 2°C 3min. or less 3 4 Room temp. 3min. or less 30±3min. After the specimens, leave it at room temperature for over 24h and then measure the sample. Moisture resistance Temperature Stability Appearance There should be no significant abnormality. The indications should be clear. L.C. Less than 1000% of initial limit ΔC / C Within ±20% of initial value Df (tan δ) Less than 300% of initial limit Temp. −55°C ΔC / C Within 0/-30% of initial value Df (tan δ) Shall be satisfied the voltage on " Standard list " Temp. +85°C ΔC / C Within +15/0% of initial value Df (tan δ) Shall be satisfied the voltage on " Standard list " L.C. Less than 1000% of initial limit Temp. +125°C ΔC / C Within +20/0% of initial value Df (tan δ) Shall be satisfied the voltage on " Standard list " L.C. Less than 1250% of initial limit Appearance There should be no significant abnormality. L.C. Less than 200% of initial value ΔC / C Within ±20% of initial value Df (tan δ) Less than 200% of initial limit Loading at Appearance High temperature L.C. Terminal strength As per 4.29 JIS C 5101-1 As per 4.13 JIS C 5101-3 − L.C. Surge voltage As per 4.22 JIS C 5101-1 As per 4.12 JIS C 5101-3 After leaving the sample under such atmospheric condition that the temperature and humidity are 60±2°C and 90 to 95% RH, respectiveiy, for 500±12h leave it at room temperature for over 24h and then measure the sample. There should be no significant abnormality. Less than 200% of initial limit ΔC / C Within +20/-30% of initial value Df (tan δ) Less than 300% of initial limit Capacitance The measured value should be stable. Appearance There should be no significant abnormality. As per 4.26JIS C 5101-1 As per 4.14JIS C 5101-3 Apply the specified surge voltage via the serial resistance of 1kΩ every 5±0.5 min. for 30±5 s. each time in the atmospheric condition of 85±2°C. Repeat this procedure 1,000 times. After the specimens, leave it at room temperature for over 24h and then measure the sample. As per 4.23 JIS C 5101-1 As per 4.15 JIS C 5101-3 After applying the rated voltage for 1000+36/0 h without discontinuation via the serial resistance of 3Ω or less at a temperature of 85±2°C, leave the sample at room temperature / humidity for over 24h and measure the value. As per 4.35 JIS C 5101-1 As per 4.9 JIS C 5101-3 A force is applied to the terminal until it bends to 1mm and by a prescribed tool maintain the condition for 5s. (See the figure below) (Unit : mm) 50 20 F (Apply force) R230 1 thickness=1.6mm 45 www.rohm.com c 2011 ROHM Co., Ltd. All rights reserved. ○ 3/5 45 2011.12 - Rev.E TCT Series U Case Data Sheet Performance Item Adhesiveness Test conditions (JIS C 5101−1 and JIS C 5101− 3) As per 4.34 JIS C 5101-1 As per 4.8 JIS C 5101-3 Apply force of 5N in the two directions shown in the figure below for 10±1s after mounting the terminal on a circuit board. The terminal should not come off. product ja Apply force a circuit board Dimensions Refer to "External dimensions" Measure using a caliper of JIS B 7507 Class 2 or higher grade. Resistance to solvents The indication should be clear As per 4.32 JIS C 5101-1 As per 4.18 JIS C 5101-3 Dip in the isopropyl alcohol for 30±5s, at room temperature. Solderability 3/4 or more surface area of the solder coated terminal dipped in the soldering bath should be covered with the new solder. As per 4.15.2 JIS C 5101-1 As per 4.7 JIS C 5101-3 Dip speed=25±2.5mm / s Pre-treatment (accelerated aging): Leave the sample on the boiling distilled water for 1 h. Solder temp. : 245±5°C Duration : 3±0.5s Solder : M705 Flux : Rosin 25% IPA 75% Vibration Capacitance Measure value should not fluctuate during the measurement. Appearance There should be no significant abnormality. As per 4.17 JIS C 5101-1 Frequency : 10 to 55 to 10Hz/min. Amplitude : 1.5mm Time : 2h each in X and Y directions Mounting : The terminal is soldered on a print circuit board. Standard products list, TCT series UCase Part No. ∗ TCT U 0E 156 M8R Rated voltage 85°C Category voltage 125°C Surge voltage 85°C (V) (V) (V) 2.5 1.6 3.2 Cap. 120Hz (μF) Df Leakage 120Hz Tolerance current (%) 25°C 1WV.5min (%) 25°C (μA) -55°C 85°C 125°C IMP 100kHz (Ω) 15 + − 20 7.5 90 50 60 25 + − 20 + − 20 1.9 35 20 25 20 2.8 90 50 60 25 + − 20 + − 20 8 90 50 60 25 0.7 35 20 25 20 + − 20 + − 20 1.4 35 20 25 20 3 90 50 60 25 + − 20 + − 20 8.6 90 50 60 25 TCT U 0G 475 M8R 4 2.5 5 4.7 ∗ TCT U 0G 685 M8R 4 2.5 5 6.8 ∗ TCT U 0G 106 M8R 4 2.5 5 10 TCT U 0J 105 M8R 6.3 4 8 1 TCT U 0J 225 M8R 6.3 4 8 2.2 ∗ TCT U 0J 475 M8R 6.3 4 8 4.7 ∗ TCT U 0J 685 M8R 6.3 4 8 6.8 ∗ TCT U 1A 155 M8R 10 6.3 13 1.5 ∗ TCT U 1A 225 M8R 10 6.3 13 2.2 ∗ TCT U 1A 335 M8R 10 6.3 13 3.3 ∗ TCT U 1A 475 M8R 10 6.3 13 4.7 ∗ TCT U 1C 105 M8R 16 10 20 1.0 1.6 90 50 60 25 + − 20 + − 20 2.2 90 50 60 25 3.3 90 50 60 25 + − 20 + − 20 9.4 90 50 60 25 1.6 90 50 60 25 ∗ =Under development www.rohm.com c 2011 ROHM Co., Ltd. All rights reserved. ○ 4/5 2011.12 - Rev.E TCT Series U Case Data Sheet Packaging specifications Case code A±0.1 B±0.1 W±0.2 E±0.1 F±0.05 P1±0.1 P2±0.1 P0±0.1 D0 t1±0.05 t2±0.1 U 0.75 1.25 8.0 1.75 3.5 2.0 2.0 4.0 φ1.55 0.20 0.60 Taping [U case] Sproket hole φD0 t1 E A F B Compoent is loaded P1 P2 W P0 t2 Feeding direction Some cases, there is center-hole on the bottom of emboss-tape. Packaging style Case code Packaging U case Taping Packaging style Symbol Basic ordering units φ180mm Reel plastic taping R 10,000pcs +1.0 9.0 0 Reel [U case] −1.5 φ180 0 φ60 +1 0 φ13+ −0.2 11.4+ −1.0 Pull direction Label sticking position EIAJ ET−7200A www.rohm.com c 2011 ROHM Co., Ltd. All rights reserved. ○ 5/5 2011.12 - Rev.E Notice Notes No copying or reproduction of this document, in part or in whole, is permitted without the consent of ROHM Co.,Ltd. The content specified herein is subject to change for improvement without notice. The content specified herein is for the purpose of introducing ROHM's products (hereinafter "Products"). If you wish to use any such Product, please be sure to refer to the specifications, which can be obtained from ROHM upon request. Examples of application circuits, circuit constants and any other information contained herein illustrate the standard usage and operations of the Products. The peripheral conditions must be taken into account when designing circuits for mass production. Great care was taken in ensuring the accuracy of the information specified in this document. However, should you incur any damage arising from any inaccuracy or misprint of such information, ROHM shall bear no responsibility for such damage. The technical information specified herein is intended only to show the typical functions of and examples of application circuits for the Products. ROHM does not grant you, explicitly or implicitly, any license to use or exercise intellectual property or other rights held by ROHM and other parties. ROHM shall bear no responsibility whatsoever for any dispute arising from the use of such technical information. The Products specified in this document are intended to be used with general-use electronic equipment or devices (such as audio visual equipment, office-automation equipment, communication devices, electronic appliances and amusement devices). The Products specified in this document are not designed to be radiation tolerant. While ROHM always makes efforts to enhance the quality and reliability of its Products, a Product may fail or malfunction for a variety of reasons. Please be sure to implement in your equipment using the Products safety measures to guard against the possibility of physical injury, fire or any other damage caused in the event of the failure of any Product, such as derating, redundancy, fire control and fail-safe designs. ROHM shall bear no responsibility whatsoever for your use of any Product outside of the prescribed scope or not in accordance with the instruction manual. The Products are not designed or manufactured to be used with any equipment, device or system which requires an extremely high level of reliability the failure or malfunction of which may result in a direct threat to human life or create a risk of human injury (such as a medical instrument, transportation equipment, aerospace machinery, nuclear-reactor controller, fuelcontroller or other safety device). ROHM shall bear no responsibility in any way for use of any of the Products for the above special purposes. If a Product is intended to be used for any such special purpose, please contact a ROHM sales representative before purchasing. If you intend to export or ship overseas any Product or technology specified herein that may be controlled under the Foreign Exchange and the Foreign Trade Law, you will be required to obtain a license or permit under the Law. Thank you for your accessing to ROHM product informations. More detail product informations and catalogs are available, please contact us. ROHM Customer Support System http://www.rohm.com/contact/ www.rohm.com © 2011 ROHM Co., Ltd. All rights reserved. R1120A