Line Filter, VI-HAM Harmonic Attenuator Module

Application NOTE
application
note | AN:102
Line Filter, VI-HAM Harmonic Attenuator Module
April 2006
Product Specifications
The VI-HAM Harmonic Attenuator Module requires an external filter to meet
international standards for EMI/RFI emissions, and incorporates transient surge
protection, as outlined in the specifications below. When used in conjunction with the VI-HAM-CM family of modules, line filter P/N 30205 will meet the requirements of VFG
243 for conducted line noise.
Figure 1.
Schematic, VI-HAM Line Filter
Cx
LINE
R
LD
Cy
CM
CM
Cy
D1
D2
LOAD
LC
D3
Cx = 1.5 F (x2) SH Cy = .01 F SH LC = 6.9 mH LD = .72 mH
R = 235K OHM D1,2 = 1.5KE130CA D3 = 1.5KE150CA
Connecting Line Filter P/N 30205
Connect single phase AC mains to the input of the line filter via a 10 A AC fuse. HAM
Connection
Diagram
Connect the output of the
filterFilter
to L1 and
L2 of the VI-HAM
(see Figure 2).
Figure 2.
Connection Diagram, VI-HAM
10A
MOV
P/N 03040
L1
GND
L2/N
LINE
AN:102
Vicor
Line Filter
P/N 30205
6.3A
L1
L2/N
L1
GATE
IN
GATE
OUT
L2/N
VI-HAM
+ OUT
P/OK
E/O
A/S
– OUT
LOAD
vicorpower.com Applications Engineering: 800 927.9474
Page 1
Specifications
Voltage Range:
85-264 VAC
Current:
6.3 A RMS
Temperature Range: –40˚C to +40˚C
Line Frequency: 47 to 63 Hz
Leakage Current: 250 V @ 60 Hz, ≤1.2 mA
Transient Surge:
1.2 /50 µs, 1 kV pulse,
Withstand: 2 joules 0 to 360˚ phase angle; exceeds IEC 801-5 Level B
Weight: 16 ounces (457 grams)
Size: 2.4" x 4.6" x 1.0" (6.1 cm x 11.7 cm x 2.54 cm)
Compatible Modules: VI-HAM; C- and I-Grade
Agency Approvals:
UL, CSA, TÜV RoHS
Figure 3.
Line Filter P/N 30205
4-40 INSERT
0.25 DP 4 PL
4.60 ±0.02
2.50
ø0.080 PIN
6 PLACES
LINE
LOAD
1.200
2.40±0.02 2.00
0.100
0.060
FACE MAY BE
BOWED 0.04 MAX
1.800
0.900
0.30 ±0.02
0.13 ±0.02
0.500
1.45
±0.02
2.800
1.00
MAX
0.500
2.260
2.000 2 PL
1.900 2 PL
A
4.410
4.000 2 PL
3.500
2.500 2 PL
.700
1.200 2 PL
.310
'0'
A
ø.102 TPH
6 PL
1.000 2 PL
.060
SEE
NOTE 1
'0' .100 2 PL
.260
NOTES
1. TOP OF INSERTS TO BE FLUSH TO .010
ABOVE TOP OF PLASTIC WASHER.
2. FILTER MUST HAVE VICOR AGENCY LABEL
(PART # 08094-01 CSA, TUV, UL).
A
'0'
A
'0'
ø.136
4 PL
MKED 'A'
REPRESENTS WORST
CASE LOCATION FOR
EDGE OF FILTER
RECOMMENDED CUSTOMER
MOUNTING
Note: The 30205 line filter is not hermetically sealed and therefore should not be subjected to post
solder aqueous rinse.
The Power Behind Performance
Rev 1.1
07/13
vicorpower.com Applications Engineering: 800 927.9474
Page 2