Line Filter P/N 30205 For use with VI-HAM 4.6 x 2.4 x 1 in (116,8 x 61,0 x 25,4 mm) Harmonic Attenuator Module Features MOV* P/N 30076 R Cx CM DM Cy D1 Cy D3 D2 LOAD • RoHS compliant LINE • Compatible with VI-HAM-xL and VI-HAM-xM Product Highlights HAM Filter P/N 30205 Cx = 1.5 uF(x2)SH Cy = 0.01 uF, Y2 type LC = 6.9 mH LD = 0.72 mH R = 235 KΩ D1,2 = 1.5KE130CA D3 = 1.5KE150CA The VI-HAM Harmonic Attenuator Module requires an external filter to meet international standards for EMI/RFI emissions, and incorporates transient surge protection, as outlined in the specifications below. Electrical Specifications Parameter Min Operating voltage Operating frequency *MOV required external to filter to meet normal mode transient surge requirements Typ Max Unit 85 264 Vac 47 63 Hz Operating current (see Figure 1) 6.3 A Leakage current at 264 Vac, 63 Hz (Either line to earth) 1.2 mA 1 kV Transient surge Withstand 2 joules Dielectric withstand (line – case) Residual voltage after 1 sec. General Specifications Parameter Min Weight Size Typ Vac 34 V Max Unit 16 (457) oz (g) 2.4 x 4.6 x 1.0 6,1 x 11,7 x 2,54 in cm Operating temperature (see Figure 1) -20 Agency approvals 1500 40 Notes 1.2/50µs pulse as per EN61000-4-5 with external MOV P/N 30076 0 to 360° phase angle; exceeds IEC 801-5, Level B Notes °C UL, CSA, TÜV Note: The 30205 line filter is not hermetically sealed and therefore should not be subjected to post solder aqueous rinse. Line Filter Rev 1.2 vicorpower.com Page 1 of 2 4/2013 800 735.6200 P/N 30205 Mechanical Outline and Recommended Layout Dimensions (All measurements are in inches) 80 70 60 50 40 90 80 INSERTION LOSS (db) OPERATING TEMP (DEG C) RATED CURRENT VS AMBIENT TEMPERATURE 90 70 DM 60 50 40 CM 30 20 10 0 1.0 2.0 3.0 4.0 CURRENT (AMPS) 5.0 6.0 Figure 1 — Current rating vs. temperature 7.0 0.01 0.04 0.1 0.4 1 4 10 0.02 0.07 0.2 0.7 2 7 20 FREQUENCY (MEGAHERTZ) Figure 2 — Insertion loss vs. frequency Line Filter Rev 1.2 vicorpower.com Page 2 of 2 4/2013 800 735.6200 40 70 100