Line Filter
P/N 30205
For use with VI-HAM
4.6 x 2.4 x 1 in
(116,8 x 61,0 x 25,4 mm)
Harmonic Attenuator Module
Features
MOV*
P/N 30076
R
Cx
CM
DM
Cy
D1
Cy
D3
D2
LOAD
• RoHS compliant
LINE
• Compatible with VI-HAM-xL
and VI-HAM-xM
Product Highlights
HAM Filter P/N 30205
Cx = 1.5 uF(x2)SH Cy = 0.01 uF, Y2 type LC = 6.9 mH LD = 0.72 mH
R = 235 KΩ D1,2 = 1.5KE130CA D3 = 1.5KE150CA
The VI-HAM Harmonic Attenuator
Module requires an external filter to meet
international standards for EMI/RFI
emissions, and incorporates transient
surge protection, as outlined in the
specifications below.
Electrical Specifications
Parameter
Min
Operating voltage
Operating frequency
*MOV required external to filter to meet normal mode transient surge requirements
Typ
Max
Unit
85
264
Vac
47
63
Hz
Operating current (see Figure 1)
6.3
A
Leakage current at 264 Vac, 63 Hz
(Either line to earth)
1.2
mA
1
kV
Transient surge
Withstand
2
joules
Dielectric withstand (line – case)
Residual voltage after 1 sec.
General Specifications
Parameter
Min
Weight
Size
Typ
Vac
34
V
Max
Unit
16 (457)
oz (g)
2.4 x 4.6 x 1.0
6,1 x 11,7 x 2,54
in
cm
Operating temperature (see Figure 1) -20
Agency approvals
1500
40
Notes
1.2/50µs pulse as per EN61000-4-5
with external MOV P/N 30076
0 to 360° phase angle; exceeds IEC 801-5, Level B
Notes
°C
UL, CSA, TÜV
Note: The 30205 line filter is not hermetically sealed and therefore should not be subjected to post solder aqueous rinse.
Line Filter
Rev 1.2
vicorpower.com
Page 1 of 2
4/2013
800 735.6200
P/N 30205
Mechanical Outline and Recommended Layout Dimensions (All measurements are in inches)
80
70
60
50
40
90
80
INSERTION LOSS (db)
OPERATING TEMP (DEG C)
RATED CURRENT VS AMBIENT TEMPERATURE
90
70
DM
60
50
40
CM
30
20
10
0
1.0
2.0 3.0 4.0
CURRENT (AMPS)
5.0
6.0
Figure 1 — Current rating vs. temperature
7.0
0.01
0.04 0.1
0.4
1
4
10
0.02 0.07 0.2
0.7 2
7
20
FREQUENCY (MEGAHERTZ)
Figure 2 — Insertion loss vs. frequency
Line Filter
Rev 1.2
vicorpower.com
Page 2 of 2
4/2013
800 735.6200
40
70
100