CUI VMS-160

page
1 of 3
date
01/2008
DESCRIPTION: open frame switching power supply
PART NUMBER: VMS-160 series
features
·industry standard 2x4” footprint
·18 W/in 3 power density
·universal input: 90~264 V ac
·active PFC
·90% typical efficiency
·12 V auxillary fan output
·full medical and ITE safety approvals
MODEL
output
voltage
current max. 1,2
(convection)
current max. 1,2
(forced air)
ripple & noise 3
(mVp-p max.)
initial voltage
set-point
VMS-160-5
VMS-160-12
VMS-160-24
VMS-160-48
ALL 12 V fan aux.
5 V dc
12 V dc
24 V dc
48 V dc
12 V dc
16 A
8.3 A
4.16 A
2.08 A
0.5 A
20 A
13.3 A
6.66 A
3.33 A
0.5 A
50 mV
120 mV
240 mV
480 mV
500 mV
±1%
±1%
±1%
±1%
±20%
notes:
1. total continuous output power will not exceed 160 W forced air (400LFM), 100 W witout fan
2. total continuous output power will not exceed 100 W forced air (400LFM), 80 W witout fan for 5 V model
3. measured at 20MHz, twisted pair with 0.47μF and 22μF parallel capacitors
INPUT
parameter
input frequency
input voltage
input current
inrush current
power factor
leakage current
conditions/description
min
47
90
AC input of 100 VAC
AC input of 200 VAC
no damage at 230 V ac cold start
when measured at full rated load and at
115 V ac / 60 Hz and 230 V ac / 50 Hz input
source input will be less than 25 Ω
compliant to EN61000-3-2 for harmonic currents
when measured per IEC 60950-1, paragraph 5.1
test voltage of 120 V ac / 60 Hz
nom
100~240
max
63
264
2.5
1.25
units
Hz
V ac
A
A
275
μA
max
units
A
%
0.98
OUTPUT
parameter
minimum loading
efficiency
conditions/description
voltage adjust
line regulation
load regulation
±10
at 90~264 V ac
±1
5, 12, 24, or 48 V outputs
±1
12 V aux. output
±20
25% I max to I max , 0.1A/μs slew rate, ±5% max. deviation, 1 ms recovery
500
0.2
16
transient response
start up time
rise
hold up time
at 20%, 50%, and 100% of max. rated load
(forced air ratings)
min
0
80
nom
90
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382
%
%
%
%
20
mS
mS
mS
PART NUMBER: VMS-160 series
page
2 of 3
date
01/2008
DESCRIPTION: open frame switching power supply
RELIABILITY
parameter
MTBF
conditions/description
235K hours min convection, 300K hours typical with 400 LFM forced air
(MIL-HDBK-217E-1, 75% of rated full load, 25°C ambient)
PROTECTION CIRCUITS
parameter
over current
output over-voltage
short circuit
conditions/description
130% max., auto recovery
130% max.
the power supply will auto recover with no damage from a short on any output.
GENERAL & SAFETY
parameter
isolation voltage
(HI-POT)
EMI/EMC
safety
RoHS
warranty
conditions/description
min
nom
max
units
applied for 1 minute.
primary to secondary:
4250
V dc
primary to earth ground:
2150
V dc
EN55022:1998 (CISPR 22 class B conducted), EN61000-3-2: 2000, EN61000-3-3: A1:2001,
EN55024 (IEC61000-4-2: 1995, IEC61000-4-3: 1995, IEC61000-4-4: 1995, IEC61000-4-5: 1995, IEC61000-4-6: 1996,
IEC61000-4-11: 1994),
CSA C 22.2 No. 60950-1/60601-1, UL 60950-1/60601-1, NEMKO EN60950-1/EN60601-1, CE-MARK
yes
standard warranty length
1
year
ENVIRONMENTAL
parameter
operating temperature
storage temperature
relative humidity
conditions/description
derate linearly to 50% load at 70°C
non-condensing operating
non-condensing non-operating
temperature coefficient
shock
operating (11mS, half sine, for a total of 6 shock inputs)
non-operating (2mS, half sine, for a total of 6 shock inputs)
vibration
operating (10~300Hz, 1 hour per axis, 3 hours total)
non-operating (10~500Hz, 1 hour per axis, 3 hours total)
min
-20
-40
8
nom
max
50
80
90
95
0.25
10
140
1
2
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382
units
°C
°C
%
%
mV/°C
G
G
Grms
Grms
PART NUMBER: VMS-160 series
page
3 of 3
date
01/2008
DESCRIPTION: open frame switching power supply
MECHANICAL DRAWING