PDF Outline drawing for HAM Filter Module

8
7
6
5
4
3
2
1
VICOR CONFIDENTIAL
REVISIONS
THIS DOCUMENT AND THE DATA DISCLOSED HEREIN OR
HEREWITH IS NOT TO BE REPRODUCED, USED OR
DISCLOSED IN WHOLE OR IN PART TO ANYONE WITHOUT
THE PERMISSION OF VICOR CORP.
REV
F
DATE
DESCRIPTION
1
RELEASED FOR E064338
REJH 08/16/06
2
REVISED PER E101020
KUK
APPROVED
SH
08/18/10
F
DCS
4-40 INSERT
.25 DP 4 PL
4.60±.02
2.50
1.200
2.00
LINE
2.40±.02
.080 PIN
6 PLACES
LOAD
E
.060
SEE NOTE 1
E
VICOR
LABEL
SEE NOTE 2
FACE MAY BE
BOWED .04 MAX
1.800
.900
.100
D
D
.30±.02
.500
C
4.410
.700
.310
'0'
3.500
BOTTOM VIEW
4.000 2PL
1.00 MAX
2.800
2.500 2PL
1.45±.02
.13±.02
1.200 2PL
.500
C
2.260
2.000 2PL
1.900 2PL
A
A
.102 TPH
6 PL
1.000 2PL
.060
SEE NOTE 1
A
'0'.100 2PL
'0'
A
.260
B
'0'
B
.136
4 PL
MKED 'A'
REPRESENTS WORST
CASE LOCATION FOR
EDGE OF FILTER
RECOMMENDED CUSTOMER
MOUNTING (TOP VIEW)
DRAWN
KNIGHT
MATERIAL
A
NOTES
1. TOP OF INSERTS TO BE FLUSH TO .010 ABOVE TOP OF PLASTIC WASHER.
2. FILTER MUST HAVE VICOR AGENCY LABEL.
3. RoHS COMPLIANT, LEAD FREE PER CST-0001 LATEST REVISION.
4. DIMENSIONS ARE INCHES ONLY.
FINISH
4/11/06
DO NOT SCALE DRAWING
8
7
6
5
4
3
FILTER HAM
P/N 30205
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE INCH [MM]
TOLERANCES ARE:
DECIMALS
ANGLES
X.XX [X.X] = ±0.01 [0.25]
±1°
X.XXX [X.XX] = ±0.005 [0.127]
THIRD ANGLE PROJECTION
SWD
VICOR
DATE
SIZE
CAGE CODE
C
67131
SCALE 1 : 1
2
A
DWG NO
REV
32723
2
SHEET 1 OF 1
1