MegaPAC™ Family AC-DC and DC-DC Switchers User and Field-Configurable Power Supplies ® C S US Overview n AC inputs available: 85 – 264 Vac, 208/240 Vac 3-Phase n Power factor corrected (some models) n Up to 4 kW n DC inputs available: 100 – 380 Vdc n User and field configurable n Compact sizes as small as: 3.4" x 6.0" x 9.5" (86,4 x 152,4 x 241,3 mm) n Fan cooled n Efficiency >80% n Up to 40 regulated outputs (up to 10 slots) from 1 to 95 Vdc and above n Full power to 45°C on most products n OVP, OTL, OCP on most outputs nAutosense n Power fail warning n Sequencing and general shut down n Agency approved cTÜVus, CE Marked n Current Sharing n Low leakage option available (some models) Description The MegaPAC family of products offers four different versions of user configurability to meet almost any set of input and output requirements. Leveraging Vicor’s modular DC-DC converters, MegaPAC family products combine feature-laden front ends with slide-in output assemblies called ConverterPACs. User configurability is at the heart of every MegaPAC. A wide variety of the same length ConverterPACs can be installed, exchanged, or removed with the turn of just one screw. This means the MegaPAC can be reconfigured to meet evolving power requirements. Given its range of configurability, the MegaPAC is appropriate for virtually any application from prototype through production. vicorpower.com • 800 927.9474 Rev 1.5 9/2014 C NRTL US MegaPAC Family Dimensions Input Voltage Output Power Number of Outputs ConverterPACs per Slot Mini MegaPAC 9.5” x 6.0” x 3.4” (241.3 x 152.4 x 86.4 mm) 90 to 132/ 180 to 264 Vac Strappable 260 to 380 Vdc 1,000 W @ 115 Vac or 230 Vac 1 to 10 (5 slots) ModuPAC, JrPAC, DualPAC, RamPAC, BatPAC PFC MegaPAC-EL/HPEL[a] 15.6” x 6.0” x 3.4” (396.2 x 152.4 x 86.4 mm) 85 to 264 Vac 100 to 380 Vdc 1,200 W @ 115 Vac 2,400 W @ 230 Vac 1 to 16 (8 slots) QPAC, DualQPAC, JrQPAC, FinQPAC[b] FinQPAC requires 2 slots PFC MegaPAC/HP 12.3” x 6.0” x 3.4” (312.4 x 152.4 x 86.4 mm) 85 to 264 Vac 100 to 380 Vdc 2,400 W @ 230 Vac 1,200 W @ 115 Vac 1 to 16 (8 slots) ModuPAC, JrPAC, DualPAC, RamPAC, BatPAC, FinPAC[a] FinPACs require 2 slots 4kW MegaPAC 14.0” x 7.5” x 4.9” (355.6 x 190.5 x 124.5 mm) 208 or 240 Vac Three Phase 260 to 352 Vdc 4,000 W - 3 phase 1 to 20 (10 slots) ModuPAC, JrPAC, DualPAC, RamPAC, BatPAC, UniPAC[b] Model [a] Low noise ripple for EL power supplies is 10 mV p-p or 0.15% whichever is greater [b] ConverterPACs with Maxi module MegaPAC Configuration DC-DC Converter DC-DC Converter At the heart of every MegaPAC are Vicor zero-current switching, DC-DC converters. The modularity of the design combined with the breadth of the product line means virtually any output voltage can be provided. ConverterPACs ConverterPAC ConverterPACs are the slide-in output assemblies that allow each MegaPAC to be easily configured to user-specified output requirements. Using the Vicor DC-DC converter, up to 600 W of output power can be provided per ConverterPAC. Larger power needs are easily handled by paralleling ConverterPACs. MegaPAC MegaPAC Each MegaPAC houses an array of user-selected ConverterPACs to provide a customized power supply. Using a different front end for each product line, almost any input power can be accommodated. The result is a customized power supply with off-the-shelf delivery. vicorpower.com • 800 927.9474 Rev 1.5 9/2014 MegaPAC Specifications (Typical at 25°C, nominal line and 75% load, unless otherwise speicified) PFC MegaPAC, PFC MegaPAC-HP Mini MegaPAC PFC MegaPAC-HPEL, PFC MegaPAC-EL 4 kW MegaPAC Input Characteristics Input 85 – 264 Vac 115 – 230 Vac, Strappable Standard line 47 – 500 Hz 208/240 Vac, 3 Φ, 4 wire 180-264 Vac, 1 Φ Vantage line 100 – 380 Vdc 260 – 352 Vdc Line regulation Inrush current 47 – 63 Hz 260 – 380 Vdc 0.2% max. from 10% to full load 25 A pk @ 115 Vac 80 A pk @ 115 & 230 Vac 30 A pk @ 230 Vac 25 A pk @ 230 Vac Ride through time >20 ms at nom. line, full load Power fail >3 ms warning Conducted EMI (47 – 63 Hz) EN 55022 Level B (certain configurations) EN 55022 Level A FCC B Power factor 0.99 (115 Vac) 0.65 0.92 (3 Φ operation) 0.98 (230 Vac) EN 55022 Level A Surge immunity EN 61000-4-5 Class 3, Performance Critera B (Common mode & normal mode) Output Characteristics Load regulation 0.2% max. from 10% to full load; 0.5% from no load to 10% load Set point accuracy Standard Line:1.0% for standard voltages, 2.0% for special or adjustable voltages Vantage Line: 2.0% for standard voltages, 5.0% for special or adjustable voltages See Vicor module specifications. A preload may be necessary for modules trimmed down below 90% of norm. output voltage. Ripple and noise (20 MHz BWL) Std. outputs: 2% or 100 mV p-p max. whichever is greater, 10% min. load VXI options: 50 mV p-p max. for outputs, ≤15 Vdc; 150 mV p-p max. 15 V<VOUT ≤24 V; 1% VOUT >24 V 2nd Generation QPAC, FinPAC, FinQPAC, and UniPAC performance dependent on the converter module used. (Output of module is unfiltered.) QPAC, DualQPAC, JuniorQPAC, RamPAC: 10 mV p-p max. or 0.15%, whichever is greater. Overcurrent protection 105 –130% >5 V outputs 30 – 125% ≤5 V outputs Overvoltage protection ModuPACs and QPACs: 115 – 135% Efficiency 80% typical Output power 1,600 W @ 40°C (230 Vac) PFC MegaPAC; 1,000 W @ 45°C (115/230Vac) 4,000 W @ 45°C (3Φ); PFC MegaPAC-EL (Low Noise) 2,400 W @ 40°C (230 Vac) PFC MegaPAC HP 1,500 W @ 45°C (1Φ); and PFC MegaPAC HPEL 1,200 W @ 40°C (115Vac) PFC MegaPACs 82% typical 82% typical Environmental Storage temperature -40°C to +85°C Operating temperature[e] Vantage line full power Vantage line half power Standard line full power Standard line half power 0 to +40°C 0 to +60°C -20 to +40°C -20 to +60°C 0 to +45°C 0 to +65°C -20 to +45°C -20 to +65°C 0 to +45°C 0 to +65°C -20 to +45°C -20 to +65°C cTÜVus, CE Mark Low Voltage Directive Safety approvals Product weights (fully configured) 9.75 lbs. (4,43 kg) (PFC MegaPAC & HP) 12.8 lbs. (5,8 kg) (PFC MegaPAC EL) 6.25 lbs. (2,84 kg) 22.0 lbs. (10 kg) 13.0 lbs. (6,0 kg) (PFC MegaPAC HPEL) Limited warranty 2 Years [e] PFC MegaPACs: The maximum operating temperature is 40°C. If using a VI-200 with output voltage < 12 V and >150 W, the operating temperature decreases to 35°C. This also applies when using a FinPAC with output voltage <24V and > 500 W. Mini MegaPAC & 4 kW MegaPACs: The operating temperature is 45°C using any combination of modules and output volt ages as long as the front-end rating is not exceeded. Normal derating applies to half power if the ambient temperature is 20°C hotter. vicorpower.com • 800 927.9474 Rev 1.5 9/2014 ConverterPAC Overview n Output voltages from 2 – 95 Vdc n Autosense/Remote Sense n Output power up to 600 W n Low noise option: n DC OK n 80 – 90% efficiency n Adjustment ranges from 10 mV p-p or 0.15%, whichever is greater n Current source outputs available 50% to 110% of nominal Modular ConverterPAC for MegaPAC Family Product Converters Module(s) Used Maximum Output Power 1 VE-200 DC-DC Converter Up to 200 Watts per ConverterPAC RamPAC (R) (RoHS - GR) 1 VE-J00 DC-DC Converter 1 Ripple Attenuator Module (VI-RAM) Up to 100 Watts for applications requiring low ripple/noise DualPAC (D) (RoHS - GD) 2 VI-J00 DC-DC Converters Dual Output; Up to 100 Watts each output JuniorPAC (J) (RoHS - GJ) 1 VI-J00 DC-DC Converter Up to 100 Watts BatPAC (B) (RoHS - GB) 1 VI-200 BatMod A 200 W programmable current source that can be configured as a battery charger QPAC [c] Low Noise (L) (RoHS - GL) 1 VI-200 DC-DC Converter with differential and common mode filters Up to 200 Watts for applications requiring as low as 10 mVp-p output noise JrQPAC [c] Low Noise (LJ) (RoHS - GLJ) 1 VE-J00 DC-DC Converter with differential and common mode filters Up to 100 W DualQPAC [c] Low Noise (LD) (RoHS - GLD) 2 VI-J00 DC-DC Converters with differential and common mode filter Dual Output; Up to 100 Watts each output UniPAC (XU) (RoHS - GXU) 1 Maxi DC-DC Converter Up to 500 Watts; Applicable for 3-phase / 4 kW product FinPAC [d] (PZ) (RoHS - GPZ) 1 Maxi DC-DC Converter Up to 600 Watts; Applicable for PFC MegaPAC High Power FinQPAC [d] (PZL) (RoHS - GPL) 1 Maxi DC-DC Converter with discrete output filter Up to 600 Watts; Applicable for PFC MegaPAC-HPEL VE-200 and VE-J00 ConverterPACs ModuPAC (M) (RoHS = GM) Maxi ConverterPACs [c] Only for the extended length MegaPACs and FinQPACs require two (2) slots [d] FinPACs vicorpower.com • 800 927.9474 Rev 1.5 9/2014 MegaPAC Mechanical Drawings Note: Newer power supplies have redesigned output studs which are 1/8th inch longer. Design guides available online at vicorpower.com for more details. PFC MegaPAC / PFC MegaPAC-High Power 12.24 (310,82) 3.37 (85,60) CUSTOMER MOUNTING HOLES (16X) M4 OR #8-32 THREAD MAXIMUM SCREW PENETRATION .150 (4.00 MM) FROM OUTSIDE SURFACE. 0.25 (6,35) 3.275 (83,19) 0.41 (10,35) D 1.458 (37,03) FAN (DIRECTION OF AIR INPUTS 115/230 VAC L1 47 TO 500 Hz L2 300VDC 0.729 (18,52) 0.470 (11,94) DO NOT OPERATE WITHOUT EARTH GROUND LABEL NO: 94-00046 REV B NOTE: SET SCREW MAXIMUM TORQUE = 4.4 INCH POUNDS 1600001 057 5.100 (129,54) MP6-78600 6.04 (153,42) 0.47 (11,94) CLAMPING SCREWS 2.75 (69,85) 14 AWG WIRE L1 5.10 (129,5) 7 SP. @ 0.7285 (18,5) PFC MegaPAC FLOW OPTIONAL) 6.75 (171,45) 0.64 (16,31) 1.40 (35,56) 1/4 - 20 SERRATED FLANGED NUT ZINC PLATED STEEL WITH OPTIONAL BUSS BARS 2.77 (70,23) L2 DO NOT OPERATE WITHOUT EARTH GROUND INPUTS 115/230 VAC 47 TO 500 Hz 300VDC 6.75 (171,45) 2.49 (63,17) NOTE: SET SCREW MAXIMUM TORQUE = 4.4 INCH POUNDS LABEL NO: 94-00046 REV B 2.92 (74,17) 0.21 (5,33) 11.93 (302,90) PFC MegaPAC-EL (Low Noise) 15.090 (383,29) 0.250 (6,35) CUSTOMER MOUNTING HOLES (4X) M4 OR #8-32 THREAD MAXIMUM SCREW PENETRATION 0.150 (4,00) FROM OUTSIDE SURFACE. 3.275 (83,19) 0.41 (10,35) 3.37 (85,60) PFC MegaPAC-EL FAN (DIRECTION OF AIR FLOW OPTIONAL) 5.100 (129,54) 6.04 (153,42) 7 SP. @ 0.7285 (18,5) = 5.10 (129,5) 47 TO 500 Hz L2 300VDC INPUTS 115/230 VAC L1 0.470 (11,94) DO NOT OPERATE WITHOUT EARTH GROUND LABEL NO: 94-00046 REV B NOTE: SET SCREW MAXIMUM TORQUE = 4.4 INCH POUNDS 0.729 (18,52) 0.470 (11,94) 0.64 (16,32) 1/4 - 20 SERRATED FLANGED NUT ZINC PLATED STEEL WITH OPTIONAL BUSS BARS CLAMPING SCREWS 14 AWG WIRE L1 INPUTS 115/230 VAC 47 TO 500 Hz 300VDC 10.010 (254,25) L2 1.40 (35,56) 2.77 (70,23) 2.487 (63,18) DO NOT OPERATE WITHOUT EARTH GROUND NOTE: SET SCREW MAXIMUM TORQUE = 4.4 INCH POUNDS 2.920 (74,17) LABEL NO: 94-00046 REV B 0.210 (5,33) 15.185 (385,70) CUSTOMER MOUNTING HOLES (4X) M4 OR #8-32 THREAD MAXIMUM SCREW PENETRATION 0.150 (4,00) FROM OUTSIDE SURFACE. vicorpower.com • 800 927.9474 Rev 1.5 9/2014 MegaPAC Mechanical Drawings Note: Newer power supplies have redesigned output studs which are 1/8th inch longer. Design guides available online at vicorpower.com for more details. Mini MegaPAC DO NOT LOOSEN OR TIGHTEN INNER NUTS 8.78 (223,0) 3.38 (85,8) 0.60 (15,2) J10 (PIN 1) 1/4 - 20 ZINC PLATED STEEL, SERRATED FLANGED NUTS 45 IN-LBS ±5 M4/#8-32 THDS 16 PLACES MAX SCREW PENETRATION - 0.15 1.80 (45,7) J2-PIN1 +P5 TYP. -P5 TYP. J2B-PIN1 (SAME AS J2) R4 "TRIMPOT" PRESENT WHEN ADJUSTABLE OUTPUT OPTION IS SPECIFIED. Mini MegaPAC 6.04 (153,4) 5.10 (129,5) 3.52 (89,4) 1 LABEL LOCATED APPROXIMATELY AS SHOWN (TYP) (MODUPAC MODEL NO.) CLAMPING SCREWS FOR INPUT LEADS, MAXIMUM TORQUE 10 IN-LBS 0.040 X 0.13 SLOT INPUT LEGEND L2 230 VAC AS IS -OR115 VAC WITH S1-S2 JUMPER 1.93 (49,0) 0.45 (11,4) 0.20 SQ. (5.2 MM) OPENINGS (J9-1 THRU J9-5) FOR #10 AWG INPUT WIRES 0.50 (12,7) L1/N J3-PIN1 +P1 TYP. J9-1 S2 J1A-PIN1 (DUAL MOD) AIR BLOCK (EXAMPLE) 1.19 (30,2) 1.06 (26,9) 2.91 (73,9) 4=SP. @ 0.7285 (18,5) R12 J1B-PIN1 (DUAL MOD) J9-5 1.40 (35,6) 0.62 (15,7) LABEL LOCATED APPROXIMATELY AS SHOWN -P1 TYP. 2.74 (69,6) 4.800 (121,8) DO NOT RUN W/O EARTH GROUND HERE. FAN MODUPAC REMOVAL STANDARD (SCALE: NONE) #4-40 CAPTIVE SCREWS TO SECURE/REMOVE MODUPACS, 5 PLACES 2.920 (74,2) AIR FLOW 9.10 (231,3) 0.220 (5,6) 9.40 (238,8) 4 kW MegaPAC 1/4 - 20 ZINC PLATED STEEL, SERRATED FLANGED NUTS 45 IN-LBS ±5 (OUTER NUT ONLY) DO NOT LOOSEN OR TIGHTEN INNER NUTS AMP NO. 746862-2 PLUG FOR FLAT RIBBON CABLE MATES WITH HSG AMP NO. 747547-2 PLUS SLIDE LATCH OR SIMILAR. 2 J2-PIN1 (16X) M4/#8-32 TAPPED HOLE .15 MAX. PENETRATION 0.560 (14,2) +P8 TYP. 0.40 (10,2) -P8 TYP. BUS BARS - FOR PARALLEL OUTPUTS R4 "TRIMPOT" PRESENT WHEN ADJUSTABLE OUTPUT OPTION IS SPECIFIED J2B-PIN1 (SAME AS J2) 4kW MegaPAC 7.50 (190,5) 1.852 (47,0) (12X) 1/8 X 1/2 SLOTS R12 J2A-PIN1 (SAME AS J2) 6.56 (166,6) 9=SP. @ .7285 (18,5) 1.852 (47,0) AIR BLOCK (EXAMPLE) BUS BAR - FOR SERIES OUTPUTS 1.20 (30,5) 0.240 (6,1) R4 DUAL MODUPAC (NO "POWER GOOD" OPTION AVAILABLE) 5.10 (129,5) J1B-PIN1 (DUAL MOD) #4-40 CAPTIVE SCREWS J1A-PIN1 TO SECURE MODUPACS (DUAL MOD) 10 PLACES 1 L1 L2 L3 S1 J2A-PIN1 (SAME AS J2) R4 DUAL MODUPAC (NO "POWER GOOD" OPTION AVAILABLE) J3-PIN1 2.068 (52,5) 1.20 (30,5) 0.46 (11,7) 2.25 (57,2) 4.90 (124,5) 6.75 (171,5) LABEL LOCATED APPROXIMATELY AS SHOWN +P1 TYP. LABEL LOCATED APPROXIMATELY AS SHOWN (TYP) (MODUPAC MODEL NO.) -P1 TYP. 0.54 (13,7) 0.31 X 1.25 AMP 1.15 (29,2) 0.25 (6,35) STANDARD AIR FLOW MODUPAC REMOVAL 1.40 (35,6) 4.00 (101,6) 0.65 (16,5) 2.25 (57,2) 6.75 (171,5) 11.95 (303,5) 1.64 (41,8) 12.28 (311,9) vicorpower.com • 800 927.9474 Rev 1.5 9/2014 Connection Diagrams Connection Diagrams, Input PFC MegaPAC/PFC MegaPAC-High Power/ PFC MegaPAC-EL/PFC MegaPAC-HPEL Mini MegaPAC 4 kW MegaPAC INPUT CONNECTIONS J9 INPUT CONNECTIONS J9 INPUT CONNECTIONS J1 J9-5 120 VAC J9-3 L1/N J9-4 120 VAC J9-2 L2 J9-1 Earth Ground J10 Interface J10-1 J10-2 J10-3 J10-4 J10-5 J10-6 J10-7 J10-8 J10-9 J10-10 J10-11 J10-12 J10 2 3 7 8 9 4 5 6 10 11 12 J1-1 Line 3 J1-2 Line 2 J9-3 AC Neutral J1-3 Line 1 J9-2 AC Hot J1-4 Earth Ground J9-1 Earth Ground E/D-1 E/D-2 E/D-3 E/D-4 E/D-5 E/D-6 E/D-7 E/D-8 Vcc +5V, 0.3A Signal Ground AC Power OK General Shutdown 1 } Jumper for 115V operation J10 Interface J10-1 E/D-1 J10-2 E/D-2 J10-3 E/D-3 J10-4 E/D-4 J10-5 E/D-5 J10-6 N/C J10-7 N/C J10-8 N/C J10-9 Vcc +5V, 0.3A J10-10 Signal Ground J10-11 AC Power OK J10-12 General Shutdown Housing-Molex P/N: 39-01-2120 Terminal-Molex P/N: 39-00-0039 Crimp Tool-Molex P/N: 11-01-0197 J10 1 2 3 7 8 9 4 5 6 10 11 12 J10 Interface 1 Signal Ground 2 Signal Ground 3 Overtemp. Warning 4 Analog Temperature 5 General Shutdown 6 No Connection 7 Enable/Disable #10 8 Enable/Disable #8 9 Enable/Disable #6 10 Enable/Disable #4 11 Enable/Disable #2 12 Signal Ground 13 Gate In Slot #1 (isolated) Molex header Mini-fit Jr. 12 POS #39-30-1120 Customer I/O interface mating receptacle Molex #39-01-2120with terminal #39-00-0039 and 18-24 AWG str anded wire. Use Molex tool #11-01-0197 1 2 3 4 5 6 14 Phase Fail Warning 15 Signal Ground 16 Vcc +5 volt, 300 mA 17 Vcc +5 volt, 300 mA 18 AC Power OK 19 AC Power Fail 20 Enable/Disable #9 21 Enable/Disable #7 22 Enable/Disable #5 23 Enable/Disable #3 24 Enable/Disable #1 25 Gate Out Slot #10 (isolated) 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Amp 25 pin connector #841-17-DBFR-DA25P plug for flat ribbon cable. Mates with housing ADAM TECH #DB25-SR-SL and contacts #DCS-01B plus slide latch #HDW-043-25. Connection Diagrams, Output ModuPAC, JuniorPAC, RamPAC MODUPAC, JRPAC, RAMPAC + V0UT J2-PIN1 1 2 3 0UTPUT ADJUST - VOUT J3-PIN1 DualPAC DUALPAC MATING HDWR: J2 (REMOTE SENSE) J1-B-PIN1 HOUSING- MOLEX P/N: 50-57-9403 TRIM PIN ACCESS TERMINALS- MOLEX P/N: 16-02-0103 CRIMP TOOL MOLEX P/N: 11-01-0208 + SENSE - SENSE J2-B-PIN1 MATING HDWR: Vcc IN HOUSING- MOLEX P/N: 39-01-0043 POWER GOOD J2-A-PIN1 TERMINALS- MOLEX P/N: 30-00-0031 CRIMP TOOL MOLEX P/N: 57005-5000 POWER GOOD INVERTED SIGNAL GROUND OUTPUT ADJUST FinPAC FINPAC BatPAC BATPAC + V0UT CURRENT LIMIT ADJUST VOLTAGE LIMIT ADJUST J2 (BATPAC REMOTE INTERFACE) 4 3 2 1 + 0UT CURRENT LIMIT ADJUST VOLTAGE LIMIT ADJUST CURRENT MONITOR - VOUT OUTPUT ADJUST - OUT - VOUT MATING HDWR: J2-PIN1 HOUSING- MOLEX P/N: 39-01-0043 TERMINALS- MOLEX P/N: 30-00-0031 CRIMP TOOL MOLEX P/N: 57005-5000 MATING HDWR: 4 5 1 2 1 AND 4 +V OUT HOUSING- MOLEX P/N: 39-01-2060 2 AND 5 -V OUT 6 3 3 +R/SENSE 6 -R/SENSE TERMINALS- MOLEX P/N: 39-00-0039 CRIMP TOOL MOLEX P/N: 11-01-0197 OUTPUT ADJUST J1-A-PIN1 J3 DC OK (POWER GOOD) 4 3 2 1 J1 (OUTPUT CONNECTORS) P2-PIN1 J2 (REMOTE SENSE) 1 2 3 MATING HDWR: TRIM PIN ACCESS HOUSING- MOLEX P/N: 50-57-9403 + SENSE TERMINALS- MOLEX P/N: 16-02-0103 CRIMP TOOL MOLEX P/N: 11-01-0208 - SENSE P2 REMOTE SENSE T RIM/SC & POWER GOOD 7 6 5 4 3 2 1 +SENSE -SENSE TRIM Vcc IN POWER GOOD POWER GOOD INVERTED SIGNAL GROUND MATING HDWR: HOUSING- MOLEX P/N: 39-01-0073 TERMINALS- MOLEX P/N: 39-00-0031 CRIMP TOOL MOLEX P/N: 57005-5000 vicorpower.com • 800 927.9474 Rev 1.5 9/2014 Connections Diagrams (continued) Connection Diagrams, Output (Continued) QPAC (L), JrQPAC QPAC, JuniorQPAC (LJ) + V0UT OUTPUT ADJUST - VOUT DualQPAC DUAL QPAC P2 REMOTE SENSE TRIM/SC & POWER GOOD 7 6 5 4 3 2 1 J1-B J1-B-PIN1 +SENSE 7 6 5 -SENSE TRIM Vcc IN POWER GOOD TRIM BOT POWER GOOD INVERTED SIGNAL GROUND N/C Vcc IN POWER GOOD P2-PIN1 TERMINALS- MOLEX P/N: 39-00-0039 CRIMP TOOL MOLEX P/N: 11-01-0197 3 +R/SENSE 6 -R/SENSE POWER GOOD INVERTED SIGNAL GROUND J1-A-PIN1 HOUSING- MOLEX P/N: 39-01-0073 HOUSING- MOLEX P/N: 39-01-2060 2 AND 5 -V OUT J1-A MATING HDWR: MATING HDWR: 1 AND 4 +V OUT 1 5 2 6 3 TRIM TOP 4 3 2 1 (OUTPUT CONNECTORS) 4 4 5 TERMINALS- MOLEX P/N: 39-00-0031 6 CRIMP TOOL MOLEX P/N: 57005-5000 (OUTPUT CONNECTORS) MATING HDWR: 1 2 1 AND 4 +V OUT HOUSING- MOLEX P/N: 39-01-2060 2 AND 5 -V OUT 3 3 +R/SENSE 6 -R/SENSE TERMINALS- MOLEX P/N: 39-00-0039 CRIMP TOOL MOLEX P/N: 11-01-0197 FinQPAC FINPAC P2 REMOTE SENSE T RIM/SC & POWER GOOD + 0UT +SENSE 7 6 5 OUTPUT ADJUST - OUT P2-PIN1 -SENSE TRIM Vcc IN POWER GOOD 4 3 2 1 POWER GOOD INVERTED SIGNAL GROUND MATING HDWR: HOUSING- MOLEX P/N: 39-01-0073 TERMINALS- MOLEX P/N: 39-00-0031 CRIMP TOOL MOLEX P/N: 57005-5000 ConverterPAC Options ModuPAC (M) BatPAC (B) DualPAC (D) Junior PAC (J) RamPAC (R) DualQPAC (LD) QPAC (L) Junior QPAC (LJ) UniPAC (XU) FinPAC (PZ)[f] FinQPAC (PLZ)[f] OPT NA NA OPT OPT[i] OPT[i] OPT OPT OPT OPT OPT OPT[g] Option D Power Good T Trim: +10%/-10% OPT[g] NA OPT OPT[g] NA OPT[g] OPT OPT OPT OPT F Trim: +10%/-50% OPT[g] NA OPT OPT[g] OPT[g] NA OPT[g] OPT OPT OPT OPT V1 VXI Low Noise (150 mV p-p 15 V <Vout ≤24 V OPT NA OPT OPT NA[h] NA[h] NA[h] NA[h] NA NA NA[h] V2 VXI Low Noise (50 mV p-p ≤15 V) OPT NA OPT OPT NA NA NA NA NA NA NA V3 VXI Low Noise (1% Vout >24) OPT NA OPT OPT NA NA NA NA NA NA NA Parallelable STD STD NA NA NA NA STD NA STD STD STD Autosense STD NA STD STD NA STD STD STD STD STD STD [f] FinPACs and FinQPACs require two slots [g] Module dependent, 3.3 V, 10 – 15 V “T” option only [h] All QPACs and RamPACs have output ripple of 10mV p-p or 0.15% whichever is greater [i] Per slot based indicator vicorpower.com • 800 927.9474 Rev 1.5 9/2014 WARRANTY Vicor products are guaranteed for two years from date of shipment against defects in material or workmanship when in normal use and service. This warranty does not extend to products subjected to misuse, accident, or improper application or maintenance. Vicor shall not be liable for collateral or consequential damage. This warranty is extended to the original purchaser only. EXCEPT FOR THE FOREGOING EXPRESS WARRANTY, VICOR MAKES NO WARRANTY, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Vicor will repair or replace defective products in accordance with its own best judgement. For service under this warranty, the buyer must contact Vicor to obtain a Return Material Authorization (RMA) number and shipping instructions. Products returned without prior authorization will be returned to the buyer. The buyer will pay all charges incurred in returning the product to the factory. Vicor will pay all reshipment charges, if the product was defective, within the terms of this warranty. Information published by Vicor has been carefully checked and is believed to be accurate; however, no responsibility is assumed for inaccuracies. Vicor reserves the right to make changes to any products without further notice to improve reliability, function, or design. Vicor does not assume any liability arising out of the application or use of any product or circuit; neither does it convey any license under its patent rights nor the rights of others. Vicor general policy does not recommend the use of its components in life support applications wherein a failure or malfunction may directly threaten life or injury. Per Vicor Terms and Conditions of Sale, the user of Vicor components in life support applications assumes all risks of such use and indemnifies Vicor against all damages. Vicor is an Equal Opportunity/Affirmative Action Employer. Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and accessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom power systems. Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor components are not designed to be used in applications, such as life support systems, wherein a failure or malfunction could result in injury or death. All sales are subject to Vicor’s Terms and Conditions of Sale, which are available upon request. Specifications are subject to change without notice. The latest data is available on the Vicor web site at vicorpower.com. Westcor, a division of Vicor, designs and builds medium to high power configurable power supplies incorporating Vicor’s high density DC-DC converters and accessory components. Westcor’s product line includes: nPFC Mini nPFC Micro nPFC MicroS nMini MegaPAC nPFC MegaPAC nPFC MegaPAC (High Power) nPFC MegaPAC-EL (Low Noise) n4 kW MegaPAC nConverterPACs nFlatPAC-EN See Design Guides for detailed information about all MegaPAC products. They can be downloaded in PDF format from the website at www.vicorpower.com. vicorpower.com • 800 927.9474 Rev 1.5 9/2014