n
AC inputs available: 85 – 264 Vac,
208/240 Vac 3-Phase
n Power factor corrected
(some models)
n Up to 4 kW
n DC inputs available: 100 – 380 Vdc
n User and field configurable
n Compact sizes as small as:
3.4" x 6.0" x 9.5"
(86,4 x 152,4 x 241,3 mm)
n Fan cooled
n Efficiency >80%
n Up to 40 regulated outputs
(up to 10 slots) from 1 to 95 Vdc and above
n Full power to 45°C on most products
n OVP, OTL, OCP on most outputs
nAutosense
n Power fail warning
n Sequencing and general shut down
n Agency approved cTÜVus, CE Marked
n Current Sharing
n Low leakage option available
(some models)
Description
The MegaPAC family of products offers four different versions of user
configurability to meet almost any set of input and output requirements.
Leveraging Vicor’s modular DC-DC converters, MegaPAC family products
combine feature-laden front ends with slide-in output assemblies called
ConverterPACs.
User configurability is at the heart of every MegaPAC. A wide variety
of the same length ConverterPACs can be installed, exchanged, or
removed with the turn of just one screw. This means the MegaPAC
can be reconfigured to meet evolving power requirements. Given its
range of configurability, the MegaPAC is appropriate for virtually any
application from prototype through production.
vicorpower.com • 800 927.9474
Rev 1.5 9/2014
C
NRTL
US
MegaPAC Family
Dimensions
Input
Voltage
Output
Power
Number
of Outputs
ConverterPACs
per Slot
Mini MegaPAC
9.5” x 6.0” x 3.4”
(241.3 x 152.4 x 86.4 mm)
90 to 132/
180 to 264 Vac Strappable
260 to 380 Vdc
1,000 W @ 115 Vac
or 230 Vac
1 to 10
(5 slots)
ModuPAC, JrPAC,
DualPAC, RamPAC,
BatPAC
PFC MegaPAC-EL/HPEL[a]
15.6” x 6.0” x 3.4”
(396.2 x 152.4 x 86.4 mm)
85 to 264 Vac
100 to 380 Vdc
1,200 W @ 115 Vac
2,400 W @ 230 Vac
1 to 16
(8 slots)
QPAC, DualQPAC,
JrQPAC, FinQPAC[b]
FinQPAC requires 2 slots
PFC MegaPAC/HP
12.3” x 6.0” x 3.4”
(312.4 x 152.4 x 86.4 mm)
85 to 264 Vac
100 to 380 Vdc
2,400 W @ 230 Vac
1,200 W @ 115 Vac
1 to 16
(8 slots)
ModuPAC, JrPAC,
DualPAC, RamPAC,
BatPAC, FinPAC[a]
FinPACs require 2 slots
4kW MegaPAC
14.0” x 7.5” x 4.9”
(355.6 x 190.5 x 124.5 mm)
208 or 240 Vac
Three Phase
260 to 352 Vdc
4,000 W - 3 phase
1 to 20
(10 slots)
ModuPAC, JrPAC,
DualPAC, RamPAC,
BatPAC, UniPAC[b]
Model
[a] Low noise ripple for EL power supplies is 10 mV p-p or 0.15% whichever is greater
[b]
ConverterPACs with Maxi module
MegaPAC Configuration
DC-DC Converter
DC-DC Converter
At the heart of every MegaPAC are Vicor zero-current switching,
DC-DC converters. The modularity of the design combined
with the breadth of the product line means virtually any output
voltage can be provided.
ConverterPACs
ConverterPAC
ConverterPACs are the slide-in output assemblies that allow
each MegaPAC to be easily configured to user-specified output
requirements. Using the Vicor DC-DC converter, up to 600 W of
output power can be provided per ConverterPAC. Larger power
needs are easily handled by paralleling ConverterPACs.
MegaPAC
MegaPAC
Each MegaPAC houses an array of user-selected ConverterPACs
to provide a customized power supply. Using a different front
end for each product line, almost any input power can be
accommodated. The result is a customized power supply with
off-the-shelf delivery.
vicorpower.com • 800 927.9474
Rev 1.5 9/2014
MegaPAC Specifications (Typical at 25°C, nominal line and 75% load, unless otherwise speicified)
PFC MegaPAC, PFC MegaPAC-HP
Mini MegaPAC
PFC MegaPAC-HPEL, PFC MegaPAC-EL
4 kW MegaPAC
Input Characteristics
Input
85 – 264 Vac
115 – 230 Vac, Strappable
Standard line
47 – 500 Hz
208/240 Vac, 3 Φ, 4 wire
180-264 Vac, 1 Φ
Vantage line
100 – 380 Vdc
260 – 352 Vdc
Line regulation
Inrush current
47 – 63 Hz
260 – 380 Vdc
0.2% max. from 10% to full load
25 A pk @ 115 Vac
80 A pk @ 115 & 230 Vac
30 A pk @ 230 Vac
25 A pk @ 230 Vac
Ride through time
>20 ms at nom. line, full load
Power fail
>3 ms warning
Conducted EMI
(47 – 63 Hz)
EN 55022 Level B (certain configurations)
EN 55022 Level A
FCC B
Power factor
0.99 (115 Vac)
0.65
0.92 (3 Φ operation)
0.98 (230 Vac)
EN 55022 Level A
Surge immunity
EN 61000-4-5 Class 3, Performance Critera B
(Common mode & normal mode)
Output Characteristics
Load regulation
0.2% max. from 10% to full load;
0.5% from no load to 10% load
Set point accuracy
Standard Line:1.0% for standard voltages, 2.0% for special or adjustable voltages
Vantage Line: 2.0% for standard voltages, 5.0% for special or adjustable voltages
See Vicor module specifications. A preload may be necessary for modules trimmed down below 90% of norm. output voltage.
Ripple and noise
(20 MHz BWL) Std. outputs: 2% or 100 mV p-p max. whichever is greater, 10% min. load
VXI options: 50 mV p-p max. for outputs, ≤15 Vdc; 150 mV p-p max. 15 V<VOUT ≤24 V; 1% VOUT >24 V
2nd Generation QPAC, FinPAC, FinQPAC, and UniPAC performance dependent on the converter module used. (Output of module is unfiltered.)
QPAC, DualQPAC, JuniorQPAC, RamPAC: 10 mV p-p max. or 0.15%, whichever is greater.
Overcurrent protection
105 –130% >5 V outputs
30 – 125% ≤5 V outputs
Overvoltage protection
ModuPACs and QPACs: 115 – 135%
Efficiency
80% typical
Output power
1,600 W @ 40°C (230 Vac) PFC MegaPAC; 1,000 W @ 45°C (115/230Vac)
4,000 W @ 45°C (3Φ);
PFC MegaPAC-EL (Low Noise)
2,400 W @ 40°C (230 Vac) PFC MegaPAC HP
1,500 W @ 45°C (1Φ);
and PFC MegaPAC HPEL
1,200 W @ 40°C (115Vac) PFC MegaPACs
82% typical
82% typical
Environmental
Storage temperature -40°C to +85°C
Operating temperature[e]
Vantage line full power Vantage line half power Standard line full power Standard line half power 0 to +40°C
0 to +60°C
-20 to +40°C
-20 to +60°C
0 to +45°C
0 to +65°C
-20 to +45°C
-20 to +65°C
0 to +45°C
0 to +65°C
-20 to +45°C
-20 to +65°C
cTÜVus, CE Mark Low Voltage Directive
Safety approvals
Product weights (fully configured) 9.75 lbs. (4,43 kg) (PFC MegaPAC & HP)
12.8 lbs. (5,8 kg) (PFC MegaPAC EL)
6.25 lbs. (2,84 kg)
22.0 lbs. (10 kg)
13.0 lbs. (6,0 kg) (PFC MegaPAC HPEL)
Limited warranty
2 Years
[e] PFC
MegaPACs: The maximum operating temperature is 40°C. If using a VI-200 with output voltage < 12 V and >150 W, the operating temperature decreases to 35°C. This also applies when using a FinPAC with output voltage <24V and > 500 W. Mini MegaPAC & 4 kW MegaPACs: The operating temperature is 45°C using any combination of modules and output volt
ages as long as the front-end rating is not exceeded. Normal derating applies to half power if the ambient temperature is 20°C hotter.
vicorpower.com • 800 927.9474
Rev 1.5 9/2014
ConverterPAC Overview
n
Output voltages from 2 – 95 Vdc
n Autosense/Remote Sense
n Output power up to 600 W
n Low noise option:
n DC OK
n 80 – 90% efficiency
n Adjustment ranges from
10 mV p-p or 0.15%, whichever is greater
n Current source outputs available
50% to 110% of nominal
Modular ConverterPAC for MegaPAC Family Product
Converters
Module(s) Used
Maximum Output Power
1 VE-200 DC-DC Converter
Up to 200 Watts per ConverterPAC
RamPAC
(R) (RoHS - GR)
1 VE-J00 DC-DC Converter
1 Ripple Attenuator Module (VI-RAM)
Up to 100 Watts for applications requiring low ripple/noise
DualPAC
(D) (RoHS - GD)
2 VI-J00 DC-DC Converters
Dual Output; Up to 100 Watts each output
JuniorPAC
(J) (RoHS - GJ)
1 VI-J00 DC-DC Converter
Up to 100 Watts
BatPAC
(B) (RoHS - GB)
1 VI-200 BatMod
A 200 W programmable current source that can be
configured as a battery charger
QPAC [c]
Low Noise
(L) (RoHS - GL)
1 VI-200 DC-DC Converter
with differential and common mode filters
Up to 200 Watts for applications requiring as low as
10 mVp-p output noise
JrQPAC [c]
Low Noise
(LJ) (RoHS - GLJ)
1 VE-J00 DC-DC Converter
with differential and common mode filters
Up to 100 W
DualQPAC [c]
Low Noise
(LD) (RoHS - GLD)
2 VI-J00 DC-DC Converters
with differential and common mode filter
Dual Output; Up to 100 Watts each output
UniPAC
(XU) (RoHS - GXU)
1 Maxi DC-DC Converter
Up to 500 Watts; Applicable for 3-phase / 4 kW product
FinPAC [d]
(PZ) (RoHS - GPZ)
1 Maxi DC-DC Converter
Up to 600 Watts; Applicable for PFC MegaPAC High Power
FinQPAC [d]
(PZL) (RoHS - GPL)
1 Maxi DC-DC Converter
with discrete output filter
Up to 600 Watts; Applicable for PFC MegaPAC-HPEL
VE-200 and VE-J00 ConverterPACs
ModuPAC
(M) (RoHS = GM)
Maxi ConverterPACs
[c] Only
for the extended length MegaPACs
and FinQPACs require two (2) slots
[d] FinPACs
vicorpower.com • 800 927.9474
Rev 1.5 9/2014
MegaPAC Mechanical Drawings
Note: Newer power supplies have redesigned output studs which are 1/8th inch longer. Design guides available online at vicorpower.com for more details.
PFC MegaPAC / PFC MegaPAC-High Power
12.24 (310,82)
3.37 (85,60)
CUSTOMER MOUNTING HOLES (16X)
M4 OR #8-32 THREAD MAXIMUM
SCREW PENETRATION .150 (4.00 MM)
FROM OUTSIDE SURFACE.
0.25 (6,35)
3.275 (83,19)
0.41 (10,35)
D
1.458 (37,03)
FAN
(DIRECTION OF AIR
INPUTS
115/230 VAC
L1
47 TO 500 Hz
L2
300VDC
0.729 (18,52)
0.470 (11,94)
DO NOT
OPERATE
WITHOUT
EARTH
GROUND
LABEL NO: 94-00046 REV B
NOTE: SET SCREW MAXIMUM
TORQUE = 4.4 INCH POUNDS
1600001 057
5.100 (129,54)
MP6-78600
6.04 (153,42)
0.47 (11,94)
CLAMPING SCREWS
2.75 (69,85)
14 AWG WIRE
L1
5.10 (129,5)
7 SP. @ 0.7285 (18,5)
PFC
MegaPAC
FLOW OPTIONAL)
6.75 (171,45)
0.64 (16,31)
1.40 (35,56)
1/4 - 20 SERRATED FLANGED
NUT ZINC PLATED STEEL
WITH OPTIONAL BUSS BARS
2.77 (70,23)
L2
DO NOT
OPERATE
WITHOUT
EARTH
GROUND
INPUTS
115/230 VAC
47 TO 500 Hz
300VDC
6.75 (171,45)
2.49 (63,17)
NOTE: SET SCREW MAXIMUM
TORQUE = 4.4 INCH POUNDS
LABEL NO: 94-00046 REV B
2.92 (74,17)
0.21 (5,33)
11.93 (302,90)
PFC MegaPAC-EL (Low Noise)
15.090 (383,29)
0.250 (6,35)
CUSTOMER MOUNTING HOLES (4X)
M4 OR #8-32 THREAD MAXIMUM
SCREW PENETRATION 0.150 (4,00)
FROM OUTSIDE SURFACE.
3.275 (83,19)
0.41 (10,35)
3.37 (85,60)
PFC
MegaPAC-EL
FAN
(DIRECTION OF AIR
FLOW OPTIONAL)
5.100 (129,54)
6.04 (153,42)
7 SP. @ 0.7285 (18,5)
= 5.10 (129,5)
47 TO 500 Hz
L2
300VDC
INPUTS
115/230 VAC
L1
0.470 (11,94)
DO NOT
OPERATE
WITHOUT
EARTH
GROUND
LABEL NO: 94-00046 REV B
NOTE: SET SCREW MAXIMUM
TORQUE = 4.4 INCH POUNDS
0.729 (18,52)
0.470 (11,94)
0.64 (16,32)
1/4 - 20 SERRATED FLANGED
NUT ZINC PLATED STEEL
WITH OPTIONAL BUSS BARS
CLAMPING SCREWS
14 AWG WIRE
L1
INPUTS
115/230 VAC
47 TO 500 Hz
300VDC
10.010 (254,25)
L2
1.40 (35,56)
2.77 (70,23)
2.487 (63,18)
DO NOT
OPERATE
WITHOUT
EARTH
GROUND
NOTE: SET SCREW MAXIMUM
TORQUE = 4.4 INCH POUNDS
2.920 (74,17)
LABEL NO: 94-00046 REV B
0.210 (5,33)
15.185 (385,70)
CUSTOMER MOUNTING HOLES (4X)
M4 OR #8-32 THREAD MAXIMUM
SCREW PENETRATION 0.150 (4,00)
FROM OUTSIDE SURFACE.
vicorpower.com • 800 927.9474
Rev 1.5 9/2014
MegaPAC Mechanical Drawings
Note: Newer power supplies have redesigned output studs which are 1/8th inch longer. Design guides available online at vicorpower.com for more details.
Mini MegaPAC
DO NOT LOOSEN OR
TIGHTEN INNER NUTS
8.78 (223,0)
3.38 (85,8)
0.60 (15,2)
J10 (PIN 1)
1/4 - 20 ZINC PLATED STEEL,
SERRATED FLANGED NUTS
45 IN-LBS ±5
M4/#8-32 THDS 16 PLACES
MAX SCREW PENETRATION - 0.15
1.80 (45,7)
J2-PIN1
+P5
TYP.
-P5 TYP.
J2B-PIN1
(SAME AS J2)
R4 "TRIMPOT" PRESENT
WHEN ADJUSTABLE OUTPUT
OPTION IS SPECIFIED.
Mini
MegaPAC
6.04 (153,4)
5.10 (129,5)
3.52 (89,4)
1
LABEL LOCATED
APPROXIMATELY
AS SHOWN (TYP)
(MODUPAC MODEL NO.)
CLAMPING SCREWS FOR INPUT LEADS,
MAXIMUM TORQUE 10 IN-LBS
0.040 X 0.13 SLOT
INPUT LEGEND
L2
230 VAC
AS IS
-OR115 VAC
WITH S1-S2
JUMPER
1.93 (49,0)
0.45 (11,4)
0.20 SQ. (5.2 MM) OPENINGS (J9-1
THRU J9-5) FOR #10 AWG INPUT WIRES
0.50 (12,7)
L1/N
J3-PIN1
+P1
TYP.
J9-1
S2
J1A-PIN1
(DUAL MOD)
AIR BLOCK
(EXAMPLE)
1.19 (30,2)
1.06 (26,9)
2.91 (73,9)
4=SP. @ 0.7285 (18,5)
R12
J1B-PIN1
(DUAL MOD)
J9-5
1.40 (35,6)
0.62 (15,7)
LABEL LOCATED
APPROXIMATELY
AS SHOWN
-P1
TYP.
2.74 (69,6)
4.800 (121,8)
DO NOT
RUN W/O
EARTH
GROUND
HERE.
FAN
MODUPAC REMOVAL
STANDARD
(SCALE: NONE)
#4-40 CAPTIVE SCREWS
TO SECURE/REMOVE
MODUPACS, 5 PLACES
2.920 (74,2)
AIR FLOW
9.10 (231,3)
0.220 (5,6)
9.40 (238,8)
4 kW MegaPAC
1/4 - 20 ZINC PLATED STEEL,
SERRATED FLANGED NUTS
45 IN-LBS ±5
(OUTER NUT ONLY)
DO NOT LOOSEN OR
TIGHTEN INNER NUTS
AMP NO. 746862-2 PLUG
FOR FLAT RIBBON CABLE
MATES WITH HSG AMP NO.
747547-2 PLUS SLIDE
LATCH OR SIMILAR.
2 J2-PIN1
(16X) M4/#8-32 TAPPED HOLE
.15 MAX. PENETRATION
0.560 (14,2)
+P8
TYP.
0.40 (10,2)
-P8 TYP.
BUS BARS - FOR
PARALLEL OUTPUTS
R4 "TRIMPOT" PRESENT
WHEN ADJUSTABLE OUTPUT
OPTION IS SPECIFIED
J2B-PIN1
(SAME AS J2)
4kW
MegaPAC
7.50 (190,5)
1.852 (47,0)
(12X) 1/8 X 1/2 SLOTS
R12
J2A-PIN1
(SAME AS J2)
6.56 (166,6)
9=SP. @ .7285 (18,5)
1.852 (47,0)
AIR BLOCK
(EXAMPLE)
BUS BAR - FOR
SERIES OUTPUTS
1.20 (30,5)
0.240 (6,1)
R4
DUAL MODUPAC
(NO "POWER GOOD"
OPTION AVAILABLE)
5.10 (129,5)
J1B-PIN1
(DUAL MOD)
#4-40 CAPTIVE SCREWS
J1A-PIN1
TO SECURE MODUPACS
(DUAL MOD)
10 PLACES
1
L1 L2 L3
S1
J2A-PIN1
(SAME AS J2)
R4
DUAL MODUPAC
(NO "POWER GOOD"
OPTION AVAILABLE)
J3-PIN1
2.068 (52,5)
1.20 (30,5)
0.46 (11,7)
2.25 (57,2)
4.90 (124,5)
6.75 (171,5)
LABEL LOCATED
APPROXIMATELY
AS SHOWN
+P1
TYP.
LABEL LOCATED
APPROXIMATELY
AS SHOWN (TYP)
(MODUPAC MODEL NO.)
-P1
TYP.
0.54 (13,7)
0.31 X 1.25 AMP
1.15 (29,2)
0.25 (6,35)
STANDARD AIR FLOW
MODUPAC REMOVAL
1.40 (35,6)
4.00 (101,6)
0.65 (16,5)
2.25 (57,2)
6.75 (171,5)
11.95 (303,5)
1.64 (41,8)
12.28 (311,9)
vicorpower.com • 800 927.9474
Rev 1.5 9/2014
Connection Diagrams
Connection Diagrams, Input
PFC MegaPAC/PFC MegaPAC-High Power/
PFC MegaPAC-EL/PFC MegaPAC-HPEL
Mini MegaPAC
4 kW MegaPAC
INPUT CONNECTIONS
J9
INPUT CONNECTIONS
J9
INPUT CONNECTIONS
J1
J9-5 120 VAC
J9-3 L1/N
J9-4 120 VAC
J9-2 L2
J9-1 Earth Ground
J10 Interface
J10-1
J10-2
J10-3
J10-4
J10-5
J10-6
J10-7
J10-8
J10-9
J10-10
J10-11
J10-12
J10
2
3
7
8
9
4
5
6
10 11 12
J1-1 Line 3
J1-2 Line 2
J9-3 AC Neutral
J1-3 Line 1
J9-2 AC Hot
J1-4 Earth Ground
J9-1 Earth Ground
E/D-1
E/D-2
E/D-3
E/D-4
E/D-5
E/D-6
E/D-7
E/D-8
Vcc +5V, 0.3A
Signal Ground
AC Power OK
General Shutdown
1
}
Jumper for
115V operation
J10 Interface
J10-1
E/D-1
J10-2
E/D-2
J10-3
E/D-3
J10-4
E/D-4
J10-5
E/D-5
J10-6
N/C
J10-7
N/C
J10-8
N/C
J10-9
Vcc +5V, 0.3A
J10-10
Signal Ground
J10-11
AC Power OK
J10-12
General Shutdown
Housing-Molex P/N: 39-01-2120
Terminal-Molex P/N: 39-00-0039
Crimp Tool-Molex P/N: 11-01-0197
J10
1
2
3
7
8
9
4
5
6
10 11 12
J10 Interface
1 Signal Ground
2 Signal Ground
3 Overtemp. Warning
4 Analog Temperature
5 General Shutdown
6 No Connection
7 Enable/Disable #10
8 Enable/Disable #8
9 Enable/Disable #6
10 Enable/Disable #4
11 Enable/Disable #2
12 Signal Ground
13 Gate In Slot #1 (isolated)
Molex header Mini-fit Jr. 12 POS #39-30-1120
Customer I/O interface mating receptacle
Molex #39-01-2120with terminal #39-00-0039
and 18-24 AWG str anded wire.
Use Molex tool #11-01-0197
1
2 3 4
5 6
14 Phase Fail Warning
15 Signal Ground
16 Vcc +5 volt, 300 mA
17 Vcc +5 volt, 300 mA
18 AC Power OK
19 AC Power Fail
20 Enable/Disable #9
21 Enable/Disable #7
22 Enable/Disable #5
23 Enable/Disable #3
24 Enable/Disable #1
25 Gate Out Slot #10 (isolated)
7 8 9 10 11 12 13
14 15 16 17 18 19 20 21 22 23 24 25
Amp 25 pin connector #841-17-DBFR-DA25P
plug for flat ribbon cable. Mates with
housing ADAM TECH #DB25-SR-SL
and contacts #DCS-01B plus slide latch
#HDW-043-25.
Connection Diagrams, Output
ModuPAC,
JuniorPAC,
RamPAC
MODUPAC, JRPAC,
RAMPAC
+ V0UT
J2-PIN1
1
2
3
0UTPUT ADJUST
- VOUT
J3-PIN1
DualPAC
DUALPAC
MATING HDWR:
J2 (REMOTE SENSE)
J1-B-PIN1
HOUSING- MOLEX P/N: 50-57-9403
TRIM PIN ACCESS
TERMINALS- MOLEX P/N: 16-02-0103
CRIMP TOOL MOLEX P/N: 11-01-0208
+ SENSE
- SENSE
J2-B-PIN1
MATING HDWR:
Vcc IN
HOUSING- MOLEX P/N: 39-01-0043
POWER GOOD
J2-A-PIN1
TERMINALS- MOLEX P/N: 30-00-0031
CRIMP TOOL MOLEX P/N: 57005-5000
POWER GOOD INVERTED
SIGNAL GROUND
OUTPUT ADJUST
FinPAC
FINPAC
BatPAC
BATPAC
+ V0UT
CURRENT LIMIT ADJUST
VOLTAGE LIMIT ADJUST
J2 (BATPAC REMOTE INTERFACE)
4
3
2
1
+ 0UT
CURRENT LIMIT ADJUST
VOLTAGE LIMIT ADJUST
CURRENT MONITOR
- VOUT
OUTPUT ADJUST
- OUT
- VOUT
MATING HDWR:
J2-PIN1
HOUSING- MOLEX P/N: 39-01-0043
TERMINALS- MOLEX P/N: 30-00-0031
CRIMP TOOL MOLEX P/N: 57005-5000
MATING HDWR:
4
5
1
2
1 AND 4 +V OUT
HOUSING- MOLEX P/N: 39-01-2060
2 AND 5 -V OUT
6
3
3 +R/SENSE 6 -R/SENSE
TERMINALS- MOLEX P/N: 39-00-0039
CRIMP TOOL MOLEX P/N: 11-01-0197
OUTPUT ADJUST
J1-A-PIN1
J3 DC OK (POWER GOOD)
4
3
2
1
J1 (OUTPUT CONNECTORS)
P2-PIN1
J2 (REMOTE SENSE)
1
2
3
MATING HDWR:
TRIM PIN ACCESS
HOUSING- MOLEX P/N: 50-57-9403
+ SENSE
TERMINALS- MOLEX P/N: 16-02-0103
CRIMP TOOL MOLEX P/N: 11-01-0208
- SENSE
P2 REMOTE SENSE T
RIM/SC & POWER GOOD
7
6
5
4
3
2
1
+SENSE
-SENSE
TRIM
Vcc IN
POWER GOOD
POWER GOOD INVERTED
SIGNAL GROUND
MATING HDWR:
HOUSING- MOLEX P/N: 39-01-0073
TERMINALS- MOLEX P/N: 39-00-0031
CRIMP TOOL MOLEX P/N: 57005-5000
vicorpower.com • 800 927.9474
Rev 1.5 9/2014
Connections Diagrams (continued)
Connection Diagrams, Output (Continued)
QPAC
(L), JrQPAC
QPAC,
JuniorQPAC
(LJ)
+ V0UT
OUTPUT ADJUST
- VOUT
DualQPAC
DUAL QPAC
P2 REMOTE SENSE TRIM/SC
& POWER GOOD
7
6
5
4
3
2
1
J1-B
J1-B-PIN1
+SENSE
7
6
5
-SENSE
TRIM
Vcc IN
POWER GOOD
TRIM BOT
POWER GOOD INVERTED
SIGNAL GROUND
N/C
Vcc IN
POWER GOOD
P2-PIN1
TERMINALS- MOLEX P/N: 39-00-0039
CRIMP TOOL MOLEX P/N: 11-01-0197
3 +R/SENSE 6 -R/SENSE
POWER GOOD INVERTED
SIGNAL GROUND
J1-A-PIN1
HOUSING- MOLEX P/N: 39-01-0073
HOUSING- MOLEX P/N: 39-01-2060
2 AND 5 -V OUT
J1-A
MATING HDWR:
MATING HDWR:
1 AND 4 +V OUT
1
5 2
6 3
TRIM TOP
4
3
2
1
(OUTPUT CONNECTORS)
4
4
5
TERMINALS- MOLEX P/N: 39-00-0031
6
CRIMP TOOL MOLEX P/N: 57005-5000
(OUTPUT CONNECTORS)
MATING HDWR:
1
2
1 AND 4 +V OUT
HOUSING- MOLEX P/N: 39-01-2060
2 AND 5 -V OUT
3
3 +R/SENSE 6 -R/SENSE
TERMINALS- MOLEX P/N: 39-00-0039
CRIMP TOOL MOLEX P/N: 11-01-0197
FinQPAC
FINPAC
P2 REMOTE SENSE T
RIM/SC & POWER GOOD
+ 0UT
+SENSE
7
6
5
OUTPUT ADJUST
- OUT
P2-PIN1
-SENSE
TRIM
Vcc IN
POWER GOOD
4
3
2
1
POWER GOOD INVERTED
SIGNAL GROUND
MATING HDWR:
HOUSING- MOLEX P/N: 39-01-0073
TERMINALS- MOLEX P/N: 39-00-0031
CRIMP TOOL MOLEX P/N: 57005-5000
ConverterPAC Options
ModuPAC
(M)
BatPAC
(B)
DualPAC
(D)
Junior
PAC
(J)
RamPAC
(R)
DualQPAC
(LD)
QPAC
(L)
Junior
QPAC
(LJ)
UniPAC
(XU)
FinPAC
(PZ)[f]
FinQPAC
(PLZ)[f]
OPT
NA
NA
OPT
OPT[i]
OPT[i]
OPT
OPT
OPT
OPT
OPT
OPT[g]
Option
D Power Good
T Trim: +10%/-10%
OPT[g]
NA
OPT
OPT[g]
NA
OPT[g]
OPT
OPT
OPT
OPT
F Trim: +10%/-50%
OPT[g]
NA
OPT
OPT[g]
OPT[g]
NA
OPT[g]
OPT
OPT
OPT
OPT
V1 VXI Low Noise
(150 mV p-p 15 V
<Vout ≤24 V
OPT
NA
OPT
OPT
NA[h]
NA[h]
NA[h]
NA[h]
NA
NA
NA[h]
V2 VXI Low Noise
(50 mV p-p ≤15 V)
OPT
NA
OPT
OPT
NA
NA
NA
NA
NA
NA
NA
V3 VXI Low Noise
(1% Vout >24)
OPT
NA
OPT
OPT
NA
NA
NA
NA
NA
NA
NA
Parallelable
STD
STD
NA
NA
NA
NA
STD
NA
STD
STD
STD
Autosense
STD
NA
STD
STD
NA
STD
STD
STD
STD
STD
STD
[f]
FinPACs and FinQPACs require two slots
[g] Module dependent, 3.3 V, 10 – 15 V “T” option only
[h] All QPACs and RamPACs have output ripple of 10mV p-p or 0.15% whichever is greater
[i] Per slot based indicator
vicorpower.com • 800 927.9474
Rev 1.5 9/2014
WARRANTY
Vicor products are guaranteed for two years from date of shipment against defects in material or workmanship when in
normal use and service. This warranty does not extend to products subjected to misuse, accident, or improper application or
maintenance. Vicor shall not be liable for collateral or consequential damage. This warranty is extended to the original purchaser only.
EXCEPT FOR THE FOREGOING EXPRESS WARRANTY, VICOR MAKES NO WARRANTY, EXPRESS OR IMPLIED, INCLUDING, BUT
NOT LIMITED TO, THE WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
Vicor will repair or replace defective products in accordance with its own best judgement. For service under this warranty,
the buyer must contact Vicor to obtain a Return Material Authorization (RMA) number and shipping instructions. Products
returned without prior authorization will be returned to the buyer. The buyer will pay all charges incurred in returning the
product to the factory. Vicor will pay all reshipment charges, if the product was defective, within the terms of this warranty.
Information published by Vicor has been carefully checked and is believed to be accurate; however, no responsibility is assumed for inaccuracies. Vicor reserves the right to make changes to any products without further notice to improve reliability,
function, or design. Vicor does not assume any liability arising out of the application or use of any product or circuit; neither
does it convey any license under its patent rights nor the rights of others. Vicor general policy does not recommend the use of
its components in life support applications wherein a failure or malfunction may directly threaten life or injury. Per Vicor Terms
and Conditions of Sale, the user of Vicor components in life support applications assumes all risks of such use and indemnifies
Vicor against all damages.
Vicor is an Equal Opportunity/Affirmative Action Employer.
Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC
modules and accessory components, fully configurable AC-DC and DC-DC power supplies,
and complete custom power systems.
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor
components are not designed to be used in applications, such as life support systems, wherein a failure or malfunction could result in
injury or death. All sales are subject to Vicor’s Terms and Conditions of Sale, which are available upon request.
Specifications are subject to change without notice.
The latest data is available on the Vicor web site at vicorpower.com.
Westcor, a division of Vicor, designs and builds medium to high power configurable power supplies incorporating Vicor’s high
density DC-DC converters and accessory components. Westcor’s product line includes:
nPFC Mini
nPFC Micro
nPFC MicroS
nMini MegaPAC
nPFC MegaPAC
nPFC MegaPAC (High Power)
nPFC MegaPAC-EL (Low Noise)
n4 kW MegaPAC
nConverterPACs
nFlatPAC-EN
See Design Guides for detailed information about all MegaPAC products. They can be downloaded in PDF format from the
website at www.vicorpower.com.
vicorpower.com • 800 927.9474
Rev 1.5 9/2014