Westcor Product Part Numbering System

Westcor Product Part Numbering System
FlatPAC-EN
FLx1-x2 x3-xxxx (-x4) (-x5)
e.g. FL4-04-2644
x1
# of outputs
x3
# of Maxi/Mini/Micro modules
FL2-02-2590-E
FL1-10-2876-LL
x4
Optional codes
G - RoHS
PFC MicroS
PFC Micro
PSx1-x2 x3-xxxx(-x4)(-x5)
e.g. PS3-03-2500
PCx1-x2 x3-(x4)xxxx(-x4)(-x5)
e.g. PC6-06-2689
PC1-02B-12
PFC Mini
x2
x5
# assigned by Westcor
x1
# of outputs
x3
# of Maxi/Mini/Micro modules
x4
Optional codes
G - RoHS
xxxx
# assigned by Westcor
x1
# of outputs
x3
# of Maxi/Mini/Micro modules
x4
Optional code
xxxx
G - RoHS
# assigned by Westcor
x2
Optional codes
x2
# of VI-200/VI-J00 modules
-x5
# of outputs
PFC MegaPAC-EL
x3
x2
# of Maxi/Mini/Micro modules
PM3-03-2643-2
PM6-60-2888-2-QF
x4
x5
Optional-denotes revision to original configuration
Optional codes
x6
Options codes e.g.:
# of VI-200/VI-J00 modules
QF - Quiet Fan
LL - Low Leakage
# assigned by Westcor
MPx A -7x B xxxx(-x C )
xA
# of outputs
xB
# of modules
e.g. MP5-784543
xxxx
# assigned by Westcor
xC
Optional codes
7
PFC chassis
G - RoHS
MXxA-7xBxxxx(-x C )
xA
# of outputs
xB
# of modules
e.g. MX4-745543
xxxx
MX
# assigned by Westcor
Maxi module used
7
xC
G
Optional codes
RoHS
xA
xxxx
# of outputs
xB
# of modules
# assigned by Westcor
xC
Optional codes
7
PFC chassis
G - RoHS
-EL
Extended length
MXx A -7x B xxxx(x C )-EL
xA
# of outputs
xB
# of modules
e.g. MX 4-74267-EL
xxxx
# assigned by Westcor
xC
Optional Codes
G - RoHS
EL
Extended length chassis
7
PFC chassis
MX
Maxi module used
MPx A -7x B xxxx(-x C )-EL
e.g. MP6-76143-EL
PFC MegaPAC-HPEL
Optional codes
PM1-03B-48
xxxx
PFC MegaPAC-HP
# of VI-200/VI-J00 modules
x5
G - RoHS
PFC MegaPAC
Optional codes e.g.:
E = Extended temp. ver.
LL = Low Leakage
xxxx
PMx1-x2 x3 (x4)-xxxx(-x5)(-x6)
e.g. PM4-22-2988
x1
# of VI-200/VI-J00 modules
Vicor 800-735-6200
Westcor Division
408-522-5280
Page 1 of 3
PFC chassis
Rev. 4/2006
Westcor Product Part Numbering System
A/R MegaPAC
MPx A -9x B xxxx(-x C )
e.g.. MP5-95143
Mini MegaPAC
MMx A -1x B xxxx(-x C )
e.g. MM4-14112
4kW MegaPAC MPxA-4xBxxxx-(xGxH)(-xC)(-EL)
e.g. MP10-410008-22(-EL)
xA
# of outputs
xB
# of modules
xxxx
# assigned by Westcor
xC
9
Autoranging chassis
Optional codes
G - ROHS
xA
# of outputs
xB
# of modules
xxxx
# assigned by Westcor
xC
1
Mini MegaPAC chassis
Optional codes
G- RoHS
xA
# of outputs
xB
# of modules
4
4kW chassis
xxxx
# assigned by Westcor
(xG=2) VI-200/VI-J00 in slot 1
(xG=3) Maxi in slot 1
(xH=2) VI-200/VI-J00 in slot 10
(xH=3) Maxi in slot 10
4kW MegaPAC MXxA-4xBxxxx-(xGxH)(-xC)(-EL)
e.g. MX5-45767-(32)(-EL)
(-xC)
Optional Code
G - RoHS
-EL
Extended length
xA
# of outputs
xB
# of modules
xC
Optional codes
4
4kW chassis
G - RoHS
xxxx
# assigned by Westcor
(xG=2) VI-200/VI-J00 or airblock in slot 1
(xG=3) Maxi/Mini/Micro in slot 1
(xH=2) VI-200/VI-J00 or airblock in slot 10
(xH=3) Maxi in slot 10
-EL
Extended length chassis
ConverterPAC Numbering System (Slide-in assemblies for MegaPAC Family)
Cx D V/x E Ax F
C
ConverterPAC type*
xE
Current out (to 1 decimal point)
e.g.M12V/8.3AD
V
xD
Stands for volt. Always listed.
Voltage out
A
xF
stands for Amps. Always listed.
Option (s )
D15V/6.7A-12V/8.3AT
* ConverterPACs with VI-200/VI-J00 modules (Non-RoHS)
M - ModuPAC
LD - DualQPAC
L - QPAC
J - JuniorPAC
LJ - Junior QPAC w/studs
B - BatPAC
D - DualPAC
R - RamPAC
* ConverterPACs with VI-200/VI-J00 modules (RoHS
GM - ModuPAC
GLD - DualQPAC
GJ - JuniorPAC
GLJ - Junior QPAC w/studs
GD - DualPAC
GR - RamPAC
Vicor 800-735-6200
Westcor Division
compliant)
GL - QPAC
GB - BatPAC
408-522-5280
Page 2 of 3
Rev. 4/2006
FOR INTERNAL
USE ONLY
Westcor Product Part Numbering System
ConverterPACs with Maxi modules
PZ - FinPAC
PZL - FinQPAC
XQ - QPAC
XU - UniPAC
ConverterPACs with Maxi Gen modules
GPZ - FinPAC
GPL - FinQPAC
GXQ - QPAC
GXU - UniPAC
*ConverterPAC Options
B
Booster module
D
DC OK or Power Good (N/A on DualPAC)
F
Full 50-110% output adjustment
F1
50-107.5% output adjustment
F2
50-105% output adjustment
F3
50-102.5% output adjustment
F4
50-100% output adjustment
F5
60-110% output adjustment
F6
70-110% output adjustment
F7
80-110% output adjustment
F8
90-110% output adjustment
F9
100-110% output adjustment
I
I-Grade module (VI-200/VI-J00)
K
Special contact factory
Local Sense (obsolete. Autosense)
L
T/H
T/H-Grade (Maxi)
M
R
S
T
T1
T2
T3
T4
Military Grade module
RAM external
Trimpot removed for external BatPAC adjustment
90-110% output adjustment
90-107.5% output adjustment
90-105% output adjustment
90-102.5% output adjustment
90-100% output adjustment
T5
T6
V1
V2
V3
P
Z
98-105% output adjustment
100-110% output adjustment
"VXI" low noise (150 mV) for >15V Vout <=24V
"VXI" low noise (50 mV) for outputs <= 15V3
1% ripple for outputs >24V3
Preload
Other special feature
Optional ConverterPAC features and options available:
Designator
(Non-RoHS)
M
D
B
J
R
L
LD
LJ
PZ
XU
XQ
PZL
Designator
(RoHS)
GM
GD
GB
GJ
GR
GL
GLD
GLJ
GPZ
GXU
GXQ
GPL
Vicor 800-735-6200
Type
D
F
R
T
V
Parallelable
ModuPAC
DualPAC
BatPAC
JuniorPAC
RamPAC
QPAC
DualQPAC
Junior QPAC
FinPAC
UniPAC
QPAC (XQ)
FinQPAC
X
NA
NA
X
X
X
X
X
X
X
X
X
X
X
NA
X
X
X
NA
X
X
X
X
X
X
X
NA
X
NA
NA
NA
NA
NA
NA
NA
NA
X
X
NA
X
X
X
NA
X
X
X
X
X
X
X
NA
X
NA
NA
NA
NA
NA
NA
NA
NA
X
NA
X
NA
NA
X
NA
NA
X
X
X
X
Westcor Division
408-522-5280
Page 3 of 3
Rev. 4/2006