MACFM-03D Wide Input, AC Encapsulated EMC Filter Module Key Features: • 85 to 305 VAC Input Electrical Specifications Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input • Compact Case Parameter • -40°C to +85°C Operation Input Voltage Range, See Note 1 • Low Cost Nominal Current, See Note 2 Conditions Min. Typ. 85 Max. Units 305 VAC 0.3 A Max. Units General Parameter Conditions Test Voltage Min. 60 Sec, 1 mA Leakage Current Conducted Emissions Typ. 2,000 EN 55022 Surge EN 61000-4-5 Parameter Conditions Operating Temperature Range Ambient Storage Temperature Range Cooling VAC Class B Criteria B; ±1 kV (1.2 µS/50 µS 2⍀) Criteria B; ±2 kV (1.2 µS/50 µS 12⍀) Min. Typ. -40 +25 -55 Max. Units +85 °C +125 °C 95 % Free Air Convection Humidity RH, Non-condensing Physical Case Size See Mechanical Drawing (Page 2) Case Material Non-Conductive Black Plastic (UL94-V0) Weight 0.71 Oz (20g) Notes: 1. The Max input voltage level of the power supply must be less than the maximum specified input of the MACFM-03D. 2. The Max input current of the power supply must be less than the maximum specified nominal current of the MACFM-03D. Schematic MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com www.micropowerdirect.com www.micropowerdirect.com Typical Connection MACFM-03D filter modules operate with MPD’s ultra-miniature 1W, 3W and 5W MPL AC/DC power supplies. The MPL units provide 1W, 3W and 5W of power from miniature SIP packages. With these modules, the AC power supply will meet the surge requirements of EN 61000-4-5 and the EMS requirements of EN 55022. Capacitors C1 and CY are required for proper operation of MPL units. Refer to the product datasheet for recommended values. Contact the factory for information on our full range of filter products. Mechanical Dimensions Pin Connections Pin 1 2 3 4 5 Function GND IN(N) IN(L) OUT(L) OUT(N) Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.02 (±0.50) MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]