MACFM-03D Datasheet

MACFM-03D
Wide Input, AC
Encapsulated EMC
Filter Module
Key Features:
• 85 to 305 VAC Input
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
• Compact Case
Parameter
• -40°C to +85°C Operation
Input Voltage Range, See Note 1
• Low Cost
Nominal Current, See Note 2
Conditions
Min.
Typ.
85
Max.
Units
305
VAC
0.3
A
Max.
Units
General
Parameter
Conditions
Test Voltage
Min.
60 Sec, 1 mA Leakage Current
Conducted Emissions
Typ.
2,000
EN 55022
Surge
EN 61000-4-5
Parameter
Conditions
Operating Temperature Range
Ambient
Storage Temperature Range
Cooling
VAC
Class B
Criteria B; ±1 kV (1.2 µS/50 µS 2⍀)
Criteria B; ±2 kV (1.2 µS/50 µS 12⍀)
Min.
Typ.
-40
+25
-55
Max.
Units
+85
°C
+125
°C
95
%
Free Air Convection
Humidity
RH, Non-condensing
Physical
Case Size
See Mechanical Drawing (Page 2)
Case Material
Non-Conductive Black Plastic (UL94-V0)
Weight
0.71 Oz (20g)
Notes:
1. The Max input voltage level of the power supply
must be less than the maximum specified input of
the MACFM-03D.
2. The Max input current of the power supply must be
less than the maximum specified nominal current
of the MACFM-03D.
Schematic
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
www.micropowerdirect.com
www.micropowerdirect.com
Typical Connection
MACFM-03D filter modules operate with MPD’s ultra-miniature 1W, 3W and 5W MPL AC/DC power supplies. The
MPL units provide 1W, 3W and 5W of power from miniature SIP packages.
With these modules, the AC power supply will meet the surge requirements of EN 61000-4-5 and the EMS requirements of
EN 55022. Capacitors C1 and CY are required for proper operation of MPL units. Refer to the product datasheet for recommended values. Contact the factory for information on our full range of filter products.
Mechanical Dimensions
Pin Connections
Pin
1
2
3
4
5
Function
GND
IN(N)
IN(L)
OUT(L)
OUT(N)
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.50)
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]