FlatPAC-EN MI Fact Sheet

FlatPAC-EN MI
New Rugged COTS FlatPAC-EN
General Specifications
Size
FlatPAC-EN MI Features
Input voltage
90 – 132 / 180 – 264, 47 – 63 Hz
250 – 380 Vdc
Up to 4 configurable outputs
Vibration:
MIL-STD-810 minimum integrity
Shock:
MIL-STD-810 40 G functional shock
Conducted emissions:
EN55022 Class A
Class B configuration dependent
Operating temperature:
-20°C to 70°C ambient
(see derating curves)
-20°C to 90°C case temp
-40°C operation optional
Maximum output power:
500 W @ 115 / 230 Vac
425 W for EN compliance
9.2 x 5.0 x 1.4 in. (233,7 x 127 x 35,6 mm)
Modules complement
VI-200, VI-J00, Maxi, Mini, Micro
Harmonic distortion
EN61000-3-2 / A14, 425 W @ 230 Vac
Voltage fluctuations and flicker
EN61000-3-3
ESD susceptibility
EN61000-4-2, Level 4, Performance Criteria A
Radiated susceptibility
EN61000-4-3, Level 4, Performance Criteria A
EFT/ Burst
EN61000-4-4, Level 4, Performance Criteria B
Surge immunity
EN61000-4-5, Installation Class 3, Performance Criteria B
(Configuration dependent)
RF common mode
EN61000-4-6, Performance Criteria A
Voltage dips and interrupts
EN61000-4-11, Performance Criteria B
Input current
9 A rms max.
Input frequency
47 – 500 Hz
Inrush current
14 A pk
Dielectric withstand
Primary to Chassis GND = 2,121 Vdc;
Primary to Secondary = 4,242 Vdc;
Secondary to Chassis GND = 750Vdc
Output ripple and noise
Standard
2% or 100 mV whichever is greater
Load regulation VI-2 / VI-J
± 0.2%; 10% to full load
± 0.5%; No load to 10% load
Load regulation Maxi, Mini, Micro
± 0.1% of Vnom; No load to full load
Efficiency
>70% typical
Weight
3.4 lbs. (1.5 kg) max.
Safety agency approvals
UL, cTÜVus, CE Marked and CB report
Warranty
2 years limited warranty
Power factor: >0.70
Conduction / convection cooled
Optional conformal coating
For more details about any Westcor products,
contact the factory at 1-800-735-6200 or go to our website at
v i c o r p o w e r. c o m