PFC Micro MI New Rugged COTS PFC Micro General Specifications Size PFC Micro MI Features Input voltage 85 – 264 Vac universal, 47 – 500 Hz 100 – 380 Vdc Up to 6 configurable outputs 10.4 x 5.06 x 1.8 in. (264,1 x 128,5 x 47,3 mm) Modules complement VI-200, VI-J00, Maxi, Mini, Micro Harmonic distortion EN61000-3-2 Voltage fluctuations and flicker EN61000-3-3 ESD susceptibility EN61000-4-2, Level 4, Performance Criteria A Radiated susceptibility EN61000-4-3, Level 4, Performance Criteria A EFT/ Burst EN61000-4-4, Level 4, Performance Criteria B Surge immunity EN61000-4-5, Installation Class 3, Performance Criteria B RF common mode EN61000-4-6, Performance Criteria A Voltage dips and interrupts EN61000-4-11, Performance Criteria B Vibration: MIL-STD-810 minimum integrity Input current 7.5 A rms max. Input frequency 47 – 500 Hz Shock: MIL-STD-810 40 G functional shock Inrush current 7 A pk @ 115 Vac; 14 A pk @ 230 Vac Dielectric withstand Primary to Chassis GND = 2,121 Vdc; Primary to Secondary = 4,242 Vdc; Secondary to Chassis GND = 750Vdc Conducted emissions: EN55022 Class A Class B configuration dependent Output ripple and noise Standard Load regulation VI-2 / VI-J Operating temperature: -20°C to 50°C @ full power -40°C to 50°C@full power (optional) ± 0.2%; 10% to full load ± 0.5%; No load to 10% load Load regulation Maxi, Mini, Micro ± 0.1% of Vnom; No load to full load Maximum output power: 500 W @ 115 Vac 800 W @ 230 Vac 2% or 100 mV whichever is greater Efficiency >75% typical Weight 5.2 lbs. (2.4 kg) max. Safety agency approvals UL, cTÜVus, CE Marked and CB report Warranty 2 years limited warranty Power factor: 0.98 typical (>75% load) Fan cooled Meets MIL-STD-704F and MIL-STD-1399C for transients and overvoltage Optional conformal coating For more details about any Westcor products, contact the factory at 1-800-735-6200 or go to our website at v i c o r p o w e r. c o m