PFC Micro MI Fact Sheet

PFC Micro MI
New Rugged COTS PFC Micro
General Specifications
Size
PFC Micro MI Features
Input voltage
85 – 264 Vac universal, 47 – 500 Hz
100 – 380 Vdc
Up to 6 configurable outputs
10.4 x 5.06 x 1.8 in. (264,1 x 128,5 x 47,3 mm)
Modules complement
VI-200, VI-J00, Maxi, Mini, Micro
Harmonic distortion
EN61000-3-2
Voltage fluctuations and flicker
EN61000-3-3
ESD susceptibility
EN61000-4-2, Level 4, Performance Criteria A
Radiated susceptibility
EN61000-4-3, Level 4, Performance Criteria A
EFT/ Burst
EN61000-4-4, Level 4, Performance Criteria B
Surge immunity
EN61000-4-5, Installation Class 3, Performance Criteria B
RF common mode
EN61000-4-6, Performance Criteria A
Voltage dips and interrupts
EN61000-4-11, Performance Criteria B
Vibration:
MIL-STD-810 minimum integrity
Input current
7.5 A rms max.
Input frequency
47 – 500 Hz
Shock:
MIL-STD-810 40 G functional shock
Inrush current
7 A pk @ 115 Vac; 14 A pk @ 230 Vac
Dielectric withstand
Primary to Chassis GND = 2,121 Vdc;
Primary to Secondary = 4,242 Vdc;
Secondary to Chassis GND = 750Vdc
Conducted emissions:
EN55022 Class A
Class B configuration dependent
Output ripple and noise
Standard
Load regulation VI-2 / VI-J
Operating temperature:
-20°C to 50°C @ full power
-40°C to 50°C@full power (optional)
± 0.2%; 10% to full load
± 0.5%; No load to 10% load
Load regulation Maxi, Mini, Micro
± 0.1% of Vnom; No load to full load
Maximum output power:
500 W @ 115 Vac
800 W @ 230 Vac
2% or 100 mV whichever is greater
Efficiency
>75% typical
Weight
5.2 lbs. (2.4 kg) max.
Safety agency approvals
UL, cTÜVus, CE Marked and CB report
Warranty
2 years limited warranty
Power factor: 0.98 typical
(>75% load)
Fan cooled
Meets MIL-STD-704F and
MIL-STD-1399C for transients
and overvoltage
Optional conformal coating
For more details about any Westcor products,
contact the factory at 1-800-735-6200 or go to our website at
v i c o r p o w e r. c o m