V23990-P848-A58/A59/C58/C59-PM preliminary datasheet Output Inverter Application flowPIM 2 3rd 1200V/4A General conditions 3phase SPWM VGEon = 15 V VGEoff = -15 V Rgon = 64 Ω Rgoff = 64 Ω IGBT Figure 1 Typical average static loss as a function of output current Ploss = f(Iout) 18 40 Ploss (W) 45 Ploss (W) FRED Figure 2 Typical average static loss as a function of output current Ploss = f(Iout) Mi*cosfi = 1 16 35 14 30 12 25 10 20 8 15 6 10 4 Mi*cosf i= -1 2 5 Mi*cosfi = -1 0 At Tj = 2 4 150 6 8 10 12 14 Iout (A) 0 16 2 At Tj = °C Mi*cosfi from -1 to 1 in steps of 0,2 4 6 150 8 10 12 14 Iout (A) 16 °C Mi*cosfi from -1 to 1 in steps of 0,2 IGBT Figure 3 Typical average switching loss as a function of output current Ploss = f(Iout) 25,0 Ploss = f(Iout) 12,0 10,0 fsw = 16kHz 20,0 FRED Figure 4 Typical average switching loss as a function of output current Ploss (W) Ploss (W) Mi*cosfi = 1 0 0 fsw = 16kHz 8,0 15,0 6,0 10,0 4,0 5,0 2,0 fsw = 2kHz fsw = 2kHz 0,0 0,0 0 At Tj = 2 150 4 6 8 10 12 14Iout (A) 0 16 At Tj = °C DC link = 600 V fsw from 2 kHz to 16 kHz in steps of factor 2 Copyright by Vincotech 2 150 4 6 8 10 12 14 16 Iout (A) °C DC link = 600 V fsw from 2 kHz to 16 kHz in steps of factor 2 1 Revision: 1 V23990-P848-A58/A59/C58/C59-PM preliminary datasheet Output Inverter Application flowPIM 2 3rd Phase Figure 5 Typical available 50Hz output current as a function Mi*cosfi Typical available 50Hz output current as a function of switching frequency Iout (A) Th = 60°C Iout (A) Phase Figure 6 Iout = f(Mi*cosfi) 6 1200V/4A Iout = f(fsw) 6 Th = 60°C Th = 100°C 5 5 Th = 100°C 4 4 3 3 2 2 1 1 0 0 -1,0 At Tj = -0,8 -0,6 -0,4 150 -0,2 0,0 0,2 0,4 0,6 0,8 1,0 Mi*cosfi 1 At Tj = °C DC link = 600 V fsw = 8 kHz Th from 60 °C to 100 °C in steps of 5 °C 10 150 100 fsw (kHz) °C DC link = 600 V Mi*cosfi = 0,8 Th from 60 °C to 100 °C in steps of 5 °C Phase Figure 7 Typical available 0Hz output current as a function Ioutpeak = f(fsw) of switching frequency Iout (Apeak) -1,00 -0,80 Iout (A) 6 Th = 60°C 5 Th = 100°C -0,60 -0,40 5,6-6,0 Phase Figure 8 Typical available 50Hz output current as a function of Iout = f(fsw, Mi*cosfi) Mi*cosfi and switching frequency 4 5,3-5,6 4,9-5,3 4,5-4,9 0,00 4,1-4,5 3,8-4,1 Mi*cosfi -0,20 3 0,20 3,4-3,8 3,0-3,4 2 0,40 0,60 1 0,80 0 1,00 1 2 4 8 16 32 64 1 fsw 10 At Tj = 150 °C At Tj = DC link = Th = 600 80 V °C DC link = 600 V Th from 60 °C to 100 °C in steps of 5 °C Mi = Copyright by Vincotech 2 150 fsw (kHz) °C 0 Revision: 1 100 V23990-P848-A58/A59/C58/C59-PM preliminary datasheet Output Inverter Application flowPIM 2 3rd Inverter Figure 9 efficiency (%) Pout (kW) Typical efficiency as a function of output power efficiency=f(Pout) 2kHz 16kHz 2,5 Inverter Figure 10 Typical available peak output power as a function of Pout=f(Th) heatsink temperature 3,0 1200V/4A 100,0 99,0 98,0 2kHz 97,0 2,0 96,0 1,5 95,0 94,0 16kHz 1,0 93,0 92,0 0,5 91,0 0,0 90,0 60 65 At Tj = 70 150 75 80 85 90 95 100 Th ( o C) 0,0 At Tj = °C DC link = 600 V Mi = 1 cosfi = 0,80 fsw from 2 kHz to 16 kHz in steps of factor 2 1,0 150 2,0 3,0 4,0 5,0 6,0 7,0 8,0 9,0 Pout (kW) °C DC link = 600 V Mi = 1 cosfi = 0,80 fsw from 2 kHz to 16 kHz in steps of factor 2 Inverter Figure 11 Overload (%) Typical available overload factor as a function of Ppeak / Pnom=f(Pnom,fsw) motor power and switching frequency 400 350 300 250 200 Switching frequency (kHz) 150 Motor nominal power (HP/kW) 100 0,50 / 0,37 0,75 / 0,55 1,00 / 0,74 1,50 / 1,10 2,00 / 1,47 3,00 / 2,21 1 599 399 300 200 150 0 2 599 399 300 200 150 0 4 599 399 300 200 150 0 8 599 399 300 200 150 0 16 599 399 300 200 150 0 At Tj = 150 °C DC link = Mi = 600 1 V cosfi = 0,8 fsw from 1 kHz to 16kHz in steps of factor 2 Th = 90 °C Motor eff = 0,85 Copyright by Vincotech 3 Revision: 1 V23990-P848-A58/A59/C58/C59-PM preliminary datasheet PRODUCT STATUS DEFINITIONS Datasheet Status Target Preliminary Final Product Status Definition Formative or In Design This datasheet contains the design specifications for product development. Specifications may change in any manner without notice. The data contained is exclusively intended for technically trained staff. First Production This datasheet contains preliminary data, and supplementary data may be published at a later date. Vincotech reserves the right to make changes at any time without notice in order to improve design. The data contained is exclusively intended for technically trained staff. Full Production This datasheet contains final specifications. Vincotech reserves the right to make changes at any time without notice in order to improve design. The data contained is exclusively intended for technically trained staff. DISCLAIMER The information given in this datasheet describes the type of component and does not represent assured characteristics. For tested values please contact Vincotech.Vincotech reserves the right to make changes without further notice to any products herein to improve reliability, function or design. Vincotech does not assume any liability arising out of the application or use of any product or circuit described herein; neither does it convey any license under its patent rights, nor the rights of others. LIFE SUPPORT POLICY Vincotech products are not authorised for use as critical components in life support devices or systems without the express written approval of Vincotech. As used herein: 1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain life, or (c) whose failure to perform when properly used in accordance with instructions for use provided in labelling can be reasonably expected to result in significant injury to the user. 2. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. Copyright by Vincotech 4 Revision: 1