70-W612M3A1K8SC01-L300FP65 target datasheet flow MNPC 12w 1200 V / 1800 A Features ● ● ● ● 3xflow SCREW 4w 12mm housing Mixed voltage NPC Low inductive High power screw interface Integrated DC-snubber capacitors Schematic Target applications ● Solar inverter ● UPS ● High Speed Motor Drive Types ● 70-W612M3A1K8SC01-L300FP65 Maximum Ratings Tj=25°C, unless otherwise specified Half Bridge Switch Copyright Vincotech 1 09 Sep. 2015 / Revision 3 70-W612M3A1K8SC01-L300FP65 target datasheet Neutral Point Diode Neutral Point Switch Half Bridge Diode Copyright Vincotech 2 09 Sep. 2015 / Revision 3 70-W612M3A1K8SC01-L300FP65 target datasheet DC-Snubber Capacitor Module Properties Copyright Vincotech 3 09 Sep. 2015 / Revision 3 70-W612M3A1K8SC01-L300FP65 target datasheet Characteristic Values Half Bridge Switch Neutral Point Diode Copyright Vincotech 4 09 Sep. 2015 / Revision 3 70-W612M3A1K8SC01-L300FP65 target datasheet Neutral Point Switch Half Bridge Diode Copyright Vincotech 5 09 Sep. 2015 / Revision 3 70-W612M3A1K8SC01-L300FP65 target datasheet DC-Snubber Capacitor Thermistor Copyright Vincotech 6 09 Sep. 2015 / Revision 3 70-W612M3A1K8SC01-L300FP65 target datasheet Pinout Copyright Vincotech 7 09 Sep. 2015 / Revision 3 70-W612M3A1K8SC01-L300FP65 target datasheet Ordering Code & Marking Version without thermal paste Ordering Code 70-W612M3A1K8SC01-L300FP65 Name Date code Lot Serial Vinco Copyright Vincotech Text in DataMatrix as L300FP65 in packaging barcode as L300FP65 Name Date code UL & Vinco Lot Serial NN-NNNNNNNNNNNNNN-NNNNNNNN WWYY UL Vinco LLLLL SSSS Datamatrix UL 8 Type Lot number Serial Date code TTTT-TTT LLLLL SSSS WWYY 09 Sep. 2015 / Revision 3 70-W612M3A1K8SC01-L300FP65 target datasheet Document No.: Date: Modification: Pages 70-W612M3A1K8SC01-L300FP65-T2-14 09 Sep. 2015 Technical name correction 1 Product status definition Datasheet Status Product Status Target Formative or In Design Definition This datasheet contains the design specifications for product development. Specifications may change in any manner without notice. The data contained is exclusively intended for technically trained staff. DISCLAIMER The information, specifications, procedures, methods and recommendations herein (together “information”) are presented by Vincotech to reader in good faith, are believed to be accurate and reliable, but may well be incomplete and/or not applicable to all conditions or situations that may exist or occur. Vincotech reserves the right to make any changes without further notice to any products to improve reliability, function or design. No representation, guarantee or warranty is made to reader as to the accuracy, reliability or completeness of said information or that the application or use of any of the same will avoid hazards, accidents, losses, damages or injury of any kind to persons or property or that the same will not infringe third parties rights or give desired results. It is reader’s sole responsibility to test and determine the suitability of the information and the product for reader’s intended use. LIFE SUPPORT POLICY Vincotech products are not authorised for use as critical components in life support devices or systems without the express written approval of Vincotech. As used herein: 1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain life, or (c) whose failure to perform when properly used in accordance with instructions for use provided in labelling can be reasonably expected to result in significant injury to the user. 2. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. Copyright Vincotech 9 09 Sep. 2015 / Revision 3