Power Modules with Phase-Change Material

Application Note
Power Modules with
Phase-Change Material
Handling of Power Modules with Pre-Applied
Phase-Change Material
Application Note no.:
AN_2012-07_001-v01
Table of Contents
Re v is i on h is to r y: ................................................................................................. 3
1
A bs tr ac t ................................................................................................... 4
2
In tr o d uc t i o n ............................................................................................. 4
3
T he P has e - c h an g e M a ter i a l ....................................................................... 4
4
V inc o tec h M o du l es wi t h Pr e - ap p l ie d P C M ................................................... 5
5
Mo u nt i n g / As s em bl y ................................................................................. 6
6
O p er a t io n ................................................................................................ 7
7
Dis as s em bl y / R eus e ................................................................................ 8
8
La b e li n g a nd Mar k i n g ................................................................................ 9
9
Co nc lus i o n ............................................................................................... 9
Disclaimer: The information in this document is given as an indication for the purpose of implementation only and
shall not be regarded as any description or warranty of a certain functionality, condition or quality. The statements
contained herein, including any recommendation, suggestion or methodology, are to be verified by the user before
implementation, as operating conditions and environmental factors may vary. It shall be the sole responsibility of the
recipient of this document to verify any function described herein in the given practical application. Vincotech GmbH
hereby disclaims any and all warranties and liabilities of any kind (including without limitation warranties of noninfringement of intellectual property rights of any third party) with respect to any and all information given in this
document.
Revision history:
Date
July 2012
Revision
Level
1
Description
First release
Handling of Power Modules with Pre-Applied Phase-Change Material
Page
number(s)
9 pages
Page 3 of 9
1
Abstract
There are several advantages to using phase-change material (PCM) rather than conventional thermal
grease as the thermal interface material (TIM) between the power module and heatsink. Vincotech offers
modules with a layer of pre-applied PCM. The thermal interface material is applied in a layer with uniform
thickness by a screen-printing process. This document describes the benefits of this phase-change
material and provides tips on handling modules.
2
Introduction
Heat has to be transferred from the module to the heatsink and thermal interface material is a necessary
evil that gets the job done. However, thermal resistance increases if the layer is too thin or thick.
Vincotech has addressed this issue by supporting modules with a pre-applied layer of phase-change
material. The module’s size and technology determines the layer’s thickness.
The phase-change material is solid at room temperature, so it requires no special care during
transportation, handling and application. Because of its thixotropic consistency, the material softens but
does not flow when heated during soldering. The surface needs protection only if the power module’s
phase-change material comes into contact with other objects during or directly after soldering, for
example, the soldering oven’s carpet. The screen-printing process is precise, thereby maximizing heattransfer capability.
The customer is spared the task of applying thermal interface material, thereby saving time and reducing
the failure risk.
3
The Phase-change Material
Vincotech uses Loctite PSX-Pm phase-change material. It has the advantage that it can be applied by
screen or stencil printing. It is fluid during the application and dries out over time and temperature. Once
the phase-change material solidifies, the module may be handled like any conventional module. Key
benefits include:

Faster, easier module mounting

Optimum thickness of the thermal interface material

Improved Rth and reduced risk of DBC cracking

Streamlined production; no need for screen-printing facilities

Automated screen printing for utmost reliability

No risk of smearing thermal paste; material is solid at room temperature

Standard solder profile applicable (e.g. J-STD-001, J-STD-003)

Compatible with Press-fit pins
Handling of Power Modules with Pre-Applied Phase-Change Material
Page 4 of 9
The table below lists the phase-change material’s physical and thermal properties. Please refer to the
manufacturer’s datasheet for more details.
Parameter
Value
Unit
Specific gravity
2
g/cm²
Thermal conductivity
3.4
W/m*K
Phase-change temperature
45
°C
Viscosity above phase-change temperature
Thixotropic
Color
Grey
Table 1: Physical and thermal properties of the phase-change material
4
Vincotech Modules with Pre-applied PCM
Vincotech offers modules with a pre-applied layer of phase-change material as indicated in Table 3. All
modules are UL-listed; therefore modules with phase-change material are also UL-approved. They come
in a standard blister box with a protective lid.
Figure 1: Modules with applied phase-change material in a blister
Modules must be stored in blister boxes under the following conditions:

Temperature: -25°C < T < 60°C

Relative humidity: 10% < rH < 95%
No aging effect is known.
This compound was subjected to a battery of tests to verify its reliability.
Test
Conditions
High temperature storage
2 x 500h @ 85°C
High humidity and high temperature
2 x 500h @ 85% rH and 85°C
Thermal shock test
100 x (30 min. @ 125°C / 30 min. @ -40°C)
Table 2: Phase-change material reliability tests
All modules had phase-change material applied and were mounted vertically to an aluminum heatsink for
these tests.
Handling of Power Modules with Pre-Applied Phase-Change Material
Page 5 of 9
The following table and figures show the pattern, thickness and dimensions of the applied phase-change
material at the back of the module after screen printing.
Parameter
Min.
Typ.
Thickness flow 0 Al2O3 DBC
30
55
Thickness flow 1 Al2O3 DBC
40
60
Thickness flow 1B
70
90
Diameter of pattern (D1, see Figure 1)
3.00
Web (D2, see Figure 1)
0.5
Table 3: Dimensions after screen-printing
Max.
80
80
110
Unit
μm
μm
µm
mm
mm
Figure 2: Dimensions and pattern after screen printing
The small triangle at the top right of the printed phase-change pattern is one of four corner markers used
to align the press-in tool for modules with Press-fit pins.
5 Mounting / Assembly
The module can be mounted to the heatsink after it has been soldered or pressed in. The procedure is
the same as the standard mounting process described in the housing specifications or handling
instructions, apart from one major difference: Screws to the heatsink can be fastened and tightened in a
single step. The phase-change material is solid at room temperature, so screws can be tightened
immediately without having to give the material any relaxation time.
Handling of Power Modules with Pre-Applied Phase-Change Material
Page 6 of 9
Pictured below is a module with melted phase-change material assembled to an inspection block.
Figure 3: Module assembled to an inspection block
Please refer to each module’s handling instructions to learn more about the heatsink properties,
mounting and handling.
6
Operation
Upon initial start-up, the Rth between the junction and the heatsink of a system without soft material will
be 10% to 15% higher than that of an operating system; that is, a system where the module is operating
a temperature higher than 45°C and the phase-change material has attained its ultimate thickness. The
higher Rth is not a problem because the heatsink temperature is below 45 to 50°C, a state at which chips
cannot overheat. Time-to-melt is a function of temperature and the speed of temperature change. The
material will not flow unless heat and force are applied.
Figure 4: Thermal resistance versus heatsink temperature
Once the module has been mounted, the system should be heated up (e.g. during the system’s burn-in
test) while leaving enough time for the phase-change material to melt. If the temperature of the PCM
exceeds 45°C, the material will melt, fill gaps and after a short time provide an optimal thermal
connection between the module and heatsink. Screws do not have to be tightened again.
Handling of Power Modules with Pre-Applied Phase-Change Material
Page 7 of 9
Figure 5: Decrease in thickness over time
The above curve shows how thickness decreases as the heatsink temperature increases at a rate of 15
K/min. with the temperature starting at 35°C. The force applied to the phase-change material was around
100 kPa, which is below the flow modules’ pressure handling capability and therefore leaves a margin for
safety.
The phase-change material returns to its solid state when the temperature drops below 45°C. This
means the material’s phase changes every time it reaches 45 °C.
7
Disassembly / Reuse
No special care has to be taken when removing the module from the heatsink. Simply loosen the screws
and use a knife to lift the module from the heatsink. Standard isopropyl or other alcohol with similar
properties may be used to clean the back of the module and the heatsink. A non-woven antistatic
microfiber cloth is best for this purpose. It is not advisable to reuse the module without cleaning it first.
The picture below shows a disassembled module that had been in operation and its heatsink print.
Figure 6: Disassembled module and its heatsink print
Standard thermal grease or the Loctite phase-change material described above can be applied before
the module is remounted.
Handling of Power Modules with Pre-Applied Phase-Change Material
Page 8 of 9
8
Labeling and Marking
All Vincotech modules come in a carton. The suffixes -/3/ indicate that it contains modules with preapplied phase-change material.
Figure 7: Label on carton
The part number printed on the module does not indicate that these modules come with phase-change
material pre-applied.
Figure 8: Part number printed on module
The “03” prefix to the RoHS indicates that this module is in revision status 03, and has no bearing on
whether or not it comes with pre-applied phase-change material.
9
Conclusion
Vincotech offers modules with pre-applied phase-change material. This PCM is applied in a screen
printing process that leaves an optimum and always consistent layer thickness. This phase-change
material is thixotropic and therefore will not flow without the application of pressure. Standard soldering
profiles may be used. A lid or a foil can prevent the phase-change material’s surface from coming into
contact with the soldering oven’s carpet.
Power modules with Press-fit pins and phase-change material are compatible. Please refer to the
module’s handling instructions to learn more about this.
Handling of Power Modules with Pre-Applied Phase-Change Material
Page 9 of 9