VER : A_1 update : 2015.03.16 DC-DC Brick BR100 SERIES 100 Watts DESCRIPTION KEY FEATURES Input under Voltage Protection The BR100 series DC-DC converter are high-efficiency and power density Over Current Protection (Hiccup Mode) standard 1/16 brick isolated models, the output power from 42W to 90W, the Short Circuit Protection (Hiccup Mode) output voltage covering 1.2V, 3.3V and 12V three levels. All models support Over Voltage Protection (Hiccup Mode) primary ON/OFF control, the 1.2V and 3.3V output models have the functions Over Temperature Protection (Self-recovery) of remote Sense and Trim. This series which conform to the RoHS6 Remote ON/OFF Control requirement can be used in the fields of communication, data transmission and distributed power supply system. Remote Sense * Output Voltage Trim * UL60950-1 and CSA C22.2 No. 60950-1-07 Meet UL94V-0 Flammability Requirements Rohs6 Compliant Size: 1.3 x 0.9 x 0.5 Inches 3-Years Product Warranty *BR100-12S without this function ELECTRICAL SPECIFICATIONS Conditions: TA = 25°C (77°F), Airflow = 1.5 m/s (300 LFM), Vin = 48 V, unless otherwise notes. Model No. Max Output Wattage (W) Voltage (V.DC.) Input Current (A) (max) No-Load Loss (W) (typ.) Voltage (V.DC.) Regulated Voltage Precision (max.) Current (A) (max.) Line Regulation (LL-HL) (typ.) Load Regulation (0-100%) (typ.) Output Ripple & Noise (peak to peak) (typ.) (Oscilloscope Bandwidth:20 MHz) Efficiency (typ.) 100% Load (Vin = 48 V; TA=25°C (77°F)) 50% Load 20% Load Over Power Protection Over Current Protection Over Voltage Protection Protection Short Circuit Protection (max.) Over Temperature Protection BR100-1.2S 42W 48V (36~75V) 2A 1.9W 1.2V 3% 35A 0.2% 0.2% BR100-3.3S 82.5W BR100-12S 90W 3.5A 2W 3.3V 3.5A 2.1W 12V 25A 7.5A 0.2% 0.3% 100 mV 200 mV 200 mV 85.5% 91% 88.5% 92% 84.5% 89.5% Hiccup mode Hiccup mode 13.8~16.2V (Hiccup mode) Hiccup mode Threshold: 105~130°C / Hysteresis:5°C (min.) Self-recovery (The values are obtained by measuring 93% 93% 88.5% the temperature of the hottest power component on the top surface of the converter.) Isolation Environment Safety EMC Physical Other Voltage (V.DC.) Operating Temperature Storage Temperature Temperature Coefficient (max.) Humidity MTBF Agency Approvals EMI (Conducted & Radiated Emission) Dimension (L x W x H) Weight Remote Low level (V.DC.) On/Off Voltage High level (V.DC.) On/Off Current Low level (mA) (max.) http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 1500 VDC (Basic Isolation) -40°C…+85°C -55°C…+125°C 0.02 % Vout / °C (TA = -40°C to +85°C (-40°F to +185°F )) 95% RH 1.5 Million Hours (Telcordia SR332; 80% load; Airflow = 1.5m/s (300 LFM); TA = 40°C (104°F) CE, UL, TUV UL60950-1 and CSA C22.2 No. 60950-1-07 1.3 x 0.9 x 0.5 Inches ( 33.0 x 22.9 x 12.7 mm ) Tolerance 0.5 mm 37 g 33 g 30 g -0.7~1.2V 3.5~12V 1mA -1- VER : A_1 update : 2015.03.16 DC-DC Brick BR100 SERIES 100 Watts NOTE 1. During the test of input reflected ripple current, the input terminal must be connected to a 12 uH inductor and a 220 uF electrolytic capacitor. 2. Point B, which is for testing the output voltage ripple, is 25 mm (0.98 in.) away from the Vout(+) pin. DERATING http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 -2- VER : A_1 update : 2015.03.16 DC-DC Brick BR100 SERIES 100 Watts MECHANICAL DIMENSION 1.2S PIN# 12S 3.3S 1 +DC IN +DC IN 2 ON / OFF CTL NC 3 -DC IN ON / OFF CTL 4 -DC OUT -DC IN 5 -Sense NC 6 Trim -DC OUT 7 +Sense NC 8 +DC OUT +DC OUT Note 1. All dimensions in mm [in.] Tolerances: x.x ± 0.5 mm [x.xx ± 0.02 in.] x.xx± 0.25 mm [x.xxx ± 0.010 in.] 2. Pin 1-3, 5-7 are 1.00 ± 0.05 mm [0.040 ± 0.002 in.] diameter with 2.00 ± 0.10 mm [0.080 ± 0.004 in.] diameter standoff shoulders. Pin4 and pin8 are 1.50 ± 0.05 mm [0.060 ± 0.002 in.] diameter with 2.50 ± 0.10 mm [0.098 ± 0.004 in.] diameter standoff shoulders. 3. M3 Screw used to bolt unit’s baseplate to other surfaces (such as heatsink) must not exceed 3.00 mm (0.120 in.) depth below the surface of baseplate http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 -3-