BR100 - ARCH Electronics Corp.

VER : A_1
update : 2015.03.16
DC-DC Brick
BR100 SERIES
100 Watts
DESCRIPTION
KEY FEATURES
 Input under Voltage Protection
The BR100 series DC-DC converter are high-efficiency and power density
 Over Current Protection (Hiccup Mode)
standard 1/16 brick isolated models, the output power from 42W to 90W, the
 Short Circuit Protection (Hiccup Mode)
output voltage covering 1.2V, 3.3V and 12V three levels. All models support
 Over Voltage Protection (Hiccup Mode)
primary ON/OFF control, the 1.2V and 3.3V output models have the functions
 Over Temperature Protection (Self-recovery)
of remote Sense and Trim. This series which conform to the RoHS6
 Remote ON/OFF Control
requirement can be used in the fields of communication, data transmission and
distributed power supply system.
 Remote Sense *
 Output Voltage Trim *
 UL60950-1 and CSA C22.2 No. 60950-1-07
 Meet UL94V-0 Flammability Requirements
 Rohs6 Compliant
 Size: 1.3 x 0.9 x 0.5 Inches
 3-Years Product Warranty
*BR100-12S without this function
ELECTRICAL SPECIFICATIONS
Conditions: TA = 25°C (77°F), Airflow = 1.5 m/s (300 LFM), Vin = 48 V, unless otherwise notes.
Model No.
Max Output Wattage (W)
Voltage (V.DC.)
Input
Current (A) (max)
No-Load Loss (W) (typ.)
Voltage (V.DC.)
Regulated Voltage Precision (max.)
Current (A) (max.)
Line Regulation (LL-HL) (typ.)
Load Regulation (0-100%) (typ.)
Output
Ripple & Noise (peak to peak) (typ.)
(Oscilloscope Bandwidth:20 MHz)
Efficiency (typ.)
100% Load
(Vin = 48 V; TA=25°C (77°F))
50% Load
20% Load
Over Power Protection
Over Current Protection
Over Voltage Protection
Protection
Short Circuit Protection (max.)
Over Temperature Protection
BR100-1.2S
42W
48V (36~75V)
2A
1.9W
1.2V
3%
35A
0.2%
0.2%
BR100-3.3S
82.5W
BR100-12S
90W
3.5A
2W
3.3V
3.5A
2.1W
12V
25A
7.5A
0.2%
0.3%
100 mV
200 mV
200 mV
85.5%
91%
88.5%
92%
84.5%
89.5%
Hiccup mode
Hiccup mode
13.8~16.2V (Hiccup mode)
Hiccup mode
Threshold: 105~130°C / Hysteresis:5°C (min.)
Self-recovery (The values are obtained by measuring
93%
93%
88.5%
the temperature of the hottest power
component on the top surface of the converter.)
Isolation
Environment
Safety
EMC
Physical
Other
Voltage (V.DC.)
Operating Temperature
Storage Temperature
Temperature Coefficient (max.)
Humidity
MTBF
Agency Approvals
EMI (Conducted & Radiated Emission)
Dimension (L x W x H)
Weight
Remote
Low level (V.DC.)
On/Off Voltage
High level (V.DC.)
On/Off Current
Low level (mA) (max.)
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
1500 VDC (Basic Isolation)
-40°C…+85°C
-55°C…+125°C
0.02 % Vout / °C (TA = -40°C to +85°C (-40°F to +185°F ))
95% RH
1.5 Million Hours
(Telcordia SR332; 80% load; Airflow = 1.5m/s (300 LFM); TA = 40°C (104°F)
CE, UL, TUV
UL60950-1 and CSA C22.2 No. 60950-1-07
1.3 x 0.9 x 0.5 Inches ( 33.0 x 22.9 x 12.7 mm ) Tolerance 0.5 mm
37 g
33 g
30 g
-0.7~1.2V
3.5~12V
1mA
-1-
VER : A_1
update : 2015.03.16
DC-DC Brick
BR100 SERIES
100 Watts
NOTE
1. During the test of input reflected ripple current, the input terminal must be connected to a 12 uH inductor and a 220 uF electrolytic capacitor.
2. Point B, which is for testing the output voltage ripple, is 25 mm (0.98 in.) away from the Vout(+) pin.
DERATING
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-2-
VER : A_1
update : 2015.03.16
DC-DC Brick
BR100 SERIES
100 Watts
MECHANICAL DIMENSION
1.2S
PIN#
12S
3.3S
1
+DC IN
+DC IN
2
ON / OFF CTL
NC
3
-DC IN
ON / OFF CTL
4
-DC OUT
-DC IN
5
-Sense
NC
6
Trim
-DC OUT
7
+Sense
NC
8
+DC OUT
+DC OUT
Note
1. All dimensions in mm [in.] Tolerances: x.x ± 0.5 mm [x.xx ± 0.02 in.] x.xx± 0.25 mm [x.xxx ± 0.010 in.]
2. Pin 1-3, 5-7 are 1.00 ± 0.05 mm [0.040 ± 0.002 in.] diameter with 2.00 ± 0.10 mm [0.080 ± 0.004 in.] diameter standoff shoulders.
Pin4 and pin8 are 1.50 ± 0.05 mm [0.060 ± 0.002 in.] diameter with 2.50 ± 0.10 mm [0.098 ± 0.004 in.] diameter standoff shoulders.
3. M3 Screw used to bolt unit’s baseplate to other surfaces (such as heatsink) must not exceed 3.00 mm (0.120 in.) depth below the surface of baseplate
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-3-