BR400 - ARCH Electronics Corp.

VER : A_1
update : 2015.03.16
DC-DC Brick
BR400 SERIES
400 Watts
DESCRIPTION
KEY FEATURES
 Input under Voltage Protection
The BR400 is an isolated DC-DC converter that uses an industry nonstandard
 Over Current Protection (Hiccup Mode)
quarter-brick structure and features high efficiency and power density.
 Short Circuit Protection (Hiccup Mode)
It provides 12 V outputs and supports the maximum output current of 33 A.
 Over Voltage Protection (Hiccup Mode)
 Over Temperature Protection (Self-recovery)
 Activates Hardware and Software *
Two BR400s can be connected in parallel to provide the maximum output
current of 54 A.
 Digitally Adjusts the Voltage *
The BR400 communicates over PMBus 1.1 to support monitoring and alarm
 PMBus Revision 1.1 compliant *
reporting functions, such as monitoring the output voltage and current, input
voltage, digitally adjusting the voltage, and activating software.
 Secondary ON/OFF Control *
 Pre-Bias Function *
 Peak Efficiency:96%(12V,16.5A)
 UL60950-1 and CSA C22.2 No. 60950-1-07
 Meet UL94V-0 Flammability Requirements
 Rohs6 Compliant
 Size: 2.28 x 1.45 x 0.5 Inches
 3-Years Product Warranty
*BR400-12S without this function
ELECTRICAL SPECIFICATIONS
Conditions: TA = 25°C (77°F), Airflow = 1.5 m/s (300 LFM), Vin = 48 V, unless otherwise notes.
Model No.
Max Output Wattage (W)
Voltage (V.DC.)
Current (A) (max)
Input
No-Load Loss (W) (typ.)
Reflected Ripple Current (peak to peak) (typ.)
Voltage (V.DC.)
Voltage Range (V.DC.)
BR400-12S
BR400-12S-P
396W
48V (36~72V)
14A (Vin= 36 - 72 V; Iout = 33 A)
3W (Vin= 48 V; Iout = 0 A)
200 mA (Oscilloscope Bandwidth:20 MHz)
12V
11.64~12.36V
11.64~12.36V (Vin= 40 - 72 V)
(Vin= 40 - 75 V; Adjust the voltage by PMBus)
10.8~12.36V (Vin= 36 - 40 V)
Output
Protection
Voltage Trim Range (V.DC.)
Current (A) (max.)
Line Regulation (LL-HL) (typ.)
Load Regulation (0-100%) (typ.)
Ripple & Noise (peak to peak) (typ.)
Efficiency
(Vin = 48 V; TA=25°C (77°F)) (typ.)
Over Power Protection
Over Current Protection
Over Voltage Protection
Short Circuit Protection (max.)
Over Temperature Protection
10.8~12.36V
(Vin= 36 - 40 V; Adjust the voltage by PMBus)
8.4~12V
33A
0.2% (Vin= 40 - 72 V; Iout = 33 A) / 10% (Vin= 36 - 40 V; Iout = 33 A)
3% (Vin = 48 V; Iout = 0 - 33 A)
200 mV (Oscilloscope Bandwidth:20 MHz)
100% Load:95% (Iout = 33 A)
50% Load:96% (Iout = 16.4 A)
100% Load:94% (Iout = 6.6 A)
Hiccup mode
Hiccup mode
14~16V (Hiccup mode)
Hiccup mode
Threshold:115~135°C / Hysteresis:10~20°C
Self-recovery (The values are obtained by measuring the temperature of the hottest power
component on the top surface of the converter.)
Isolation
Environment
Safety
EMC
Physical
Voltage (V.DC.)
Operating Temperature
Storage Temperature
Temperature Coefficient (max.)
Humidity
MTBF
Agency Approvals
EMI (Conducted & Radiated Emission)
Dimension (L x W x H)
Weight
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
1500 VDC (Functional Isolation)
-40°C…+85°C
-55°C…+125°C
0.02 % Vout / °C (TA = -40°C to +85°C (-40°F to +185°F ))
95% RH
1.5 Million Hours
(Telcordia SR332; 80% load; Airflow = 1.5m/s (300 LFM); TA = 40°C (104°F)
CE, UL, TUV
UL60950-1 and CSA C22.2 No. 60950-1-07
2.28 x 1.45 x 0.5 Inches ( 57.9 x 36.8 x 12.7 mm ) Tolerance 0.5 mm
66 g
-1-
VER : A_1
update : 2015.03.16
DC-DC Brick
BR400 SERIES
400 Watts
ELECTRICAL SPECIFICATIONS
Conditions: TA = 25°C (77°F), Airflow = 1.5 m/s (300 LFM), Vin = 48 V, unless otherwise notes.
Model No.
Other
BR400-12S
-0.7~1.2V
Low level (V.DC.)
-0.7~1.2V
High level (V.DC.)
2.8~8V
Low level (mA) (max.)
1mA
Low level (V.DC.)
─
0~0.8V
High level (V.DC.)
─
2.1~3.3V
Primary On/Off Voltage
Primary On/Off Current
BR400-12S-P
Secondary CTL Voltage
─
Secondary CTL Current
Low level (mA) (max.)
Logic Input and Output Pins in the Communications Port
─
Logic Input Low level (V.DC.) (max.)
─
Logic Input High Level (V.DC.) (max.)
─
Logic Output Low Level (V.DC.) (max.)
─
Logic Output High Level (V.DC.) (max.)
─
PMBus Setting-up Time (ns.) (min.)
─
PMBus Holding Time (ns.) (min.)
PMBus Detected Precision (Vin=36 - 72 V; Iout=0 - 33 A;TA = -40°C to +85°C (-40°F to +185°F ))
─
Input Voltage Detected Precision (V.DC.)
Output Voltage Detected Precision (V.DC.) ─
─
Output Current Detected Precision (A)
─
Output Power Detected Precision (W)
─
Temperature Detected Precision (°C)
(The Low Electric Level is Effective)
2.8~8V
(The Low Electric Level is Effective)
(The High Electric Level is Effective)
(The High Electric Level is Effective)
1mA
0.8V
3.6V
0.25V
3.6V
100
0
1V
0.2V
1A
12.56W
5°C
NOTE
1. During the test of input reflected ripple current, the input terminal must be connected to a 12 uH inductor and a 220 uF electrolytic capacitor.
2. Point B, which is for testing the output voltage ripple, is 25 mm (0.98 in.) away from the Vout(+) pin.
DERATING
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-2-
VER : A_1
update : 2015.03.16
DC-DC Brick
BR400 SERIES
400 Watts
MECHANICAL DIMENSION
PIN#
Single
1
+DC IN
2
ON / OFF CTL
3
-DC IN
4
-DC OUT
5
+DC OUT
6
SGND
7
SA0
8
PMBus_ALT
9
SA1
10
PMBus_CTL
11
ISHARE
12
PMBus_SCL
13
PMBus_SDA
Note
1. All dimensions in mm [in.]
Tolerances: x.x ± 0.5 mm [x.xx ± 0.02 in.]
x.xx± 0.25 mm [x.xxx ± 0.010 in.]
2. Pin 1-3 are 1.00 ± 0.05 mm [0.040 ± 0.002 in.] diameter
with 2.00 ± 0.10 mm [0.080 ± 0.004 in.] diameter standoff shoulders.
Pin4 and pin5 are 1.50 ± 0.05 mm [0.060 ± 0.002 in.]
diameter with 2.50 ± 0.10 mm [0.098 ± 0.004 in.] diameter standoff shoulders.
Pin6 and pin13 are 0.64 ± 0.05 mm [0.025 ± 0.002 in. ] diameter.
3. M3 Screw used to bolt unit’s baseplate to other surfaces (such as heatsink) must
not exceed 3.00 mm [0.120 in.] depth below the surface of baseplate.
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-3-