DC-DC Brick
BR130 SERIES
36/60/72/100/132 Watts
DESCRIPTION
KEY FEATURES












Input under Voltage Protection
Over Current Protection (Hiccup Mode)
Short Circuit Protection (Hiccup Mode)
Over Voltage Protection (Hiccup Mode)
Over Temperature Protection (Self-recovery)
Remote ON/OFF Control
Remote Sense
Output Voltage Trim
UL60950-1 and CSA C22.2 No. 60950-1-07
Meet UL94V-0 Flammability Requirements
Rohs6 Compliant
Size: 2.28 x 1.45 x 0.38 Inches (others Model)
2.28 x 1.45 x 0.39 Inches (BR130-3.3S)
2.28 x 1.45 x 0.5 Inches (BR130-3.3SB)
 3-Years Product Warranty
The BR130 series is a new generation isolated DC-DC converter that uses an
industry standard quarter-brick structure, and features high efficiency and
power density, operates from an input voltage range of 36 V to 75 V,
provides the rated output voltage of 1.2V / 1.5V / 1.8V / 2.5V / 3.3V and the
maximum output current of 30A / 40A.
BR130-1.2S / 1.5S / 1.8S / 2.5S / 3.3S
BR130-3.3SB
ELECTRICAL SPECIFICATIONS
Conditions: TA = 25°C (77°F), Airflow = 1 m/s (200 LFM), Vin = 48 V, unless otherwise notes.
BR130-
Model No.
Max Output Wattage (W)
Voltage (V.DC.)
Input
Current (A) (max)
No-Load Loss (W) (typ.)
Voltage (V.DC.)
Regulated Voltage Precision (max.)
Current (A) (max.)
Line Regulation (LL-HL) (typ.)
Load Regulation (0-100%) (typ.)
Output
Ripple & Noise (peak to peak) (typ.)
(Oscilloscope Bandwidth:20 MHz)
Efficiency (typ.)
100% Load
(Vin = 48 V; TA=25°C (77°F))
50% Load
20% Load
Over Power Protection
Over Current Protection
Over Voltage Protection
Protection
Short Circuit Protection (max.)
Over Temperature Protection
BR130-
BR130-
BR130-
BR130-
BR130-
1.2S
1.5S
36W
60W
48V (36~75V)
1.3A
2A
1W
2W
1.2V
1.5V
3%
30A
40A
0.2%
0.2%
0.2%
0.3%
1.8S
72W
2.5S
100W
3.3S
132W
3.3SB
2.4A
2W
1.8V
3.5A
3.5W
2.5V
4.5A
3.6W
3.3V
1%
1%
0.2%
0.3%
0.2%
0.3%
100 mV
100 mV
100 mV
120 mV
89.5%
90.5%
89.5%
91.5%
─
87%
Hiccup mode
Hiccup mode
1.4~2.0V
1.8~2.5V
91.5%
92%
87%
92%
92%
86.5%
93.5%
93.5%
87.5%
2.2~3.0V
3.0~3.8V
3.9~4.7V
(Hiccup mode)
(Hiccup mode)
(Hiccup mode)
(Hiccup mode)
100 mV
(Hiccup mode)
Hiccup mode
Threshold:115~135°C (typ.) / Hysteresis:5°C (min.)
Self-recovery (The values are obtained by measuring the temperature
93.5%
93.5%
─
of the hottest power
component on the top surface of the converter.)
Isolation
Environment
Safety
EMC
Physical
Other
Voltage (V.DC.)
Operating Temperature
Storage Temperature
Temperature Coefficient (max.)
Humidity
MTBF
Agency Approvals
EMI (Conducted & Radiated Emission)
Dimension (L x W x H)
Tolerance 0.5 mm
Weight
Remote
On/Off Voltage
On/Off Current
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
Low level (V.DC.)
High level (V.DC.)
Low level (mA) (max.)
1500 VDC (Functional Isolation)
-40°C…+85°C
-55°C…+125°C
0.02 % Vout / °C (TA = -40°C to +85°C (-40°F to +185°F ))
95% RH
2.5
1.5
1.5
1.5
1.5
2.5
Million Hr
Million Hr
Million Hr
Million Hr
Million Hr
Million Hr
(Telcordia SR332; 80% load; Airflow = 1.5m/s (300 LFM); TA = 40°C (104°F)
CE, UL, TUV
UL60950-1 and CSA C22.2 No. 60950-1-07
BR130-3.3SB: 2.28 x 1.45 x 0.5 Inches ( 57.9 x 36.8 x 12.7 mm )
BR130-3.3S: 2.28 x 1.45 x 0.39 Inches ( 57.9 x 36.8 x 9.8 mm )
others:
2.28 x 1.45 x 0.38 Inches ( 57.9 x 36.8 x 9.7 mm )
38 g
38 g
38 g
38 g
40 g
58 g
-0.7~1.2V
3.5~12V
1mA
-1-
VER : A_1
update : 2015.03.16
DC-DC Brick
BR130 SERIES
36/60/72/100/132 Watts
NOTE
1. During the test of input reflected ripple current, the input terminal must be connected to a 12uH inductor and a 220uF electrolytic capacitor.
2. Point B, which is for testing the output voltage ripple, is 25 mm (0.98 in.) away from the Vout(+) pin.
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-2-
VER : A_1
update : 2015.03.16
DC-DC Brick
BR130 SERIES
36/60/72/100/132 Watts
DERATING
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-3-
VER : A_1
update : 2015.03.16
DC-DC Brick
BR130 SERIES
36/60/72/100/132 Watts
MECHANICAL DIMENSION
BR130-1.2S / BR130-1.5S / BR130-1.8S / BR130-2.5S / BR130-3.3S
PIN#
Single
1
+DC IN
2
ON / OFF CTL
3
-DC IN
4
-DC OUT
5
-Sense
6
TRIM
7
+Sense
8
+DC OUT
Note
1. All dimensions in mm [in.] Tolerances: x.x ± 0.5 mm [x.xx ± 0.02 in.] x.xx± 0.25 mm [x.xxx ± 0.010 in.]
2. Pin 1-3, 5-7 are 1.00 ± 0.05 mm [0.040 ± 0.002 in.] diameter with 2.00 ± 0.10 mm [0.080 ± 0.004 in.] diameter standoff shoulders.
Pin4 and pin8 are 1.50 ± 0.05 mm [0.060 ± 0.002 in.] diameter with 2.50 ± 0.10 mm [0.098 ± 0.004 in.] diameter standoff shoulders.
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-4-
VER : A_1
update : 2015.03.16
DC-DC Brick
BR130 SERIES
36/60/72/100/132 Watts
MECHANICAL DIMENSION
BR130-3.3SB
PIN#
Single
1
+DC IN
2
ON / OFF CTL
3
-DC IN
4
-DC OUT
5
-Sense
6
TRIM
7
+Sense
8
+DC OUT
Note
1. All dimensions in mm [in.] Tolerances: x.x ± 0.5 mm [x.xx ± 0.02 in.] x.xx± 0.25 mm [x.xxx ± 0.010 in.]
2. Pin 1-3, 5-7 are 1.00 ± 0.05 mm [0.040 ± 0.002 in.] diameter with 2.00 ± 0.10 mm [0.080 ± 0.004 in.] diameter standoff shoulders.
Pin4 and pin8 are 1.50 ± 0.05 mm [0.060 ± 0.002 in.] diameter with 2.50 ± 0.10 mm [0.098 ± 0.004 in.] diameter standoff shoulders.
3. M3 Screw used to bolt unit’s baseplate to other surfaces (such as heatsink) must not exceed 3.00 mm (0.120 in.) depth below the
surface of baseplate.