QLF60 SERIES
60 Watts
KEY FEATURES










IP66/67 Design for Indoor or LED Outdoor Installations
With Constant Current & Constant Voltage (C.C+C.V mode)
With P.F.C. Function, PF>0.9
High Efficiency up to 90%
Free Air Convection
Protections: Over Load / Over Voltage / Short Circuit
High Reliability & Double Layered PCB
Suitable for LED lighting and moving sign applications
Ultra Compact Size: 4.72 x 2.36 x 1.38 Inches
3-Year Product Warranty
ELECTRICAL SPECIFICATIONS
All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated.
Model No.
QLF60-24S
Max output wattage
(W)
(Note2)
50 / 60 Hz
Power factor
PF>0.9 at Full load (115 VAC / 230 VAC)
Current (Full load)
0.8A (115 VAC) / 0.4A (230 VAC)
(at 230 VAC)
< 0.7 mA max at 240 VAC
Voltage (V.DC.)
24V
36V
48V
54V
22 ~ 26.5V
33 ~ 39.5V
44 ~ 51.5V
49 ~ 55V
Constant Current Operation Voltage (max)
(CC Mode)
(Note3)
(CV Mode)
15.6~ 24
VDC
23.4~36
VDC
36~48
VDC
35.1~54
VDC
Voltage Tolerance
Preset Current (mA)
(at IP66)
(CC Mode)
(at 230 VAC)
Current Adjustment Range (mA)
(CC Mode)
Preset Current (mA)
(at IP67)
(CC Mode) (fixed) (Note4)
(at 230 VAC)
Minimum Load (mA)
±10%
2450
1750
1050
1050
2000~2500
1350~1750
1000~1300
900~1150
2450 (2000~2500)
1750 (1350~1750)
1250 (1000~1300)
1050 (900~1150)
2000
1350
1000
900
Line Regulation (typ.)
±4%
(110-240 VAC)
Load Regulation (Min-Max) (typ.)
Isolation
45 A max.
Leakage Current
Voltage ADJ Range Setup
Protection
QLF60-54S
90-295 VAC
Frequency (Hz)
Inrush current
Output
QLF60-48S
60W
Voltage
Input
QLF60-36S
±5%
Ripple & Noise (typ.) (Note1)
2.7Vp-p
Efficiency (at 230VAC / Full Load)(typ)
89%
Over current protection
Auto recovery
Over voltage protection
Zener diode clamp
Short circuit protection
Auto recovery
Input-Output (V.AC)
3750V
Input-FG
(V.AC)
1880V
Output-FG
.(V.AC)
Operating temperature
5Vp-p
500V
-30°C…+70°C (with derating)
Storage temperature
-40°C…+85°C
Temperature coefficient
0.02%/°C
Humidity
95% RH
MTBF
>450,000 h @ 25°C (MIL-HDBK-217F)
Dimension (L x W x H)
4.72 x 2.36 x 1.38 Inches
Weight
600 g
Cooling method
Free air convection
Safety
Agency Approvals
UL8750、IEC / EN 61347-2-13、 IEC / EN 61347-1
EMC
EMI
(Conducted & Radiated Emission)
EMS (Noise Immunity)
EN 61547
Harmonic Current
EN 61000-3-2(at Full Load)、EN 61000-3-3
Surge
2KV L-N, 4KV L N-FG
Environment
Physical
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
( 120.0 x 60.0 x 35.0 mm ) Tolerance 2mm
EN 55015
-1-
VER : A_5
update : 2015.05.15
LED Power
QLF60 SERIES
60 Watts
Note:
1. Ripple & Noise are measured at 20MHz of bandwidth with 0.1uF & 47uF parallel capacitor.
2. Please check the derating curve for more details.
3. Input Voltage=115 or 230 VAC。This is the suitable operation region for LED related application.but please reconfirm special electrical requirements
for some specific system design.
4. Please contact us for more information.
5. It's recommended to add Varistor 14S561K at L / N input side in parallel.
6. This driver is suggested for LED application only.
7. Direct connection to LEDs is suggested. Connecting additional drivers would not be appropriate.
This series has IP66 and IP67, when you place order, please be noted as ordering Part No.
Model No.
Ordering Part No
MECHANICAL DIMENSION
QLF60-24S
QLF60-36S
QLF60-48S
QLF60-54S
IP66
QLF60-24S-IP66
QLF60-36S-IP66
QLF60-48S-IP66
QLF60-54S-IP66
IP67
QLF60-24S-IP67
QLF60-36S-IP67
QLF60-48S-IP67
QLF60-54S-IP67
( Top View )
BLOCK DIAGRAM
ASSEMBLY INSTRUCTIONS
*U Case T=2.0mm
Customer screws into the length of the case
no higher than 0.5mm
(Namely screw length for load plate thickness
plus 2.5mm
DERATING
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-2-