Rotary Type RDC40/RDC50/RDC90 Series1248KB

RDC40
RDC50 Rotary Type
RDC90 Rotary sensors catering to diverse position
detection needs
■ Typical Specifications
Specifications
Items
RDC40
RDC50
Rated voltage
RDC90
5V DC
Operating life
1,000,000
cycles
100,000 cycles
Total resistance
10,000,000
cycles
3.3kΩ (RDC9010001)
10kΩ (RDC9010003)
10kΩ
Operating
temperature range
−30℃ to +80℃
−40℃ to +120℃
Product Line
Mounting method
Linearity
guarantee range
Linearity
Hollow shaft variation
Operating life
(cycles)
Connector type
13 rotations
±1%
−
100,000
φ3.5 dia
Horizontal type
φ3.5 dia with radius
Resistive
Position Sensors
Vertical type
320°
±2%
Reflow type
φ3.5 dia
1,000,000
φ3.5 dia with radius
Reflow type(Low-profile)
φ4 dia
60°
Reflow type
(Long-life)
±3%
244°
φ3.5 dia
10,000,000
Minimum order unit(pcs.)
Japan
Export
770
770
1,500
3,000
1,600
1,600
3,900
3,900
3,600
3,600
1,960
1,960
Model No.
Drawing No.
RDC401D07A
1
RDC501015A
2
RDC501011A
3
RDC502010A
4
RDC503013A
5
RDC503015A
6
RDC506002A
7
RDC9010001
RDC9010003
8
Note
Other varieties are also available. Please inquire.
Packing Specifications
Tray / Taping
Series
Unit:mm
Packing
Specifications
RDC40
RDC501
1 case /export packing
770
770
1,500
3,000
1,600
1,600
3,900
3,900
3,600
3,600
1,960
1,960
Taping
RDC506
RDC90
1 case /Japan
Tape width
(mm)
Export package
measurements(mm)
Reel size(Taping)
526×370×191
Tray
RDC502
RDC503
Number of packages(pcs.)
Tray
ー
ole
13 h
370×280×92
24
407×415×135
ー
240×300×270
Inside 25.4
Outside 29.4
Refer to P.477 for product specifications.
Refer to P.478 for soldering conditions.
466
RDC40/RDC50/RDC90/Rotary Type
■ Dimensions
Photo
Style
RDC40(Multiple turns type)
32
5
5
6.8
3.2
28
26.6
ø1.5
No.
Unit:mm
CW
A
4.3
1
CCW
R
10
10.6
0.
5
0.45
1.5
Term. No.
3T
1T
2T
A Detail
RDC501(Horizontal type)
2T
Mounting face
5.
5
3.5
3
1T
2T
3T
11
5
4-ø1
6.5
2
6.95
7.5
3
5.45
2.5
0.1
Resistive
Position Sensors
R
0.6
ø3.5
1
5
4-0.8
RDC501
(Horizontal type, V3.5 dia with radius)
5
R5
.
3
1T
2T
3T
11
1
4-ø1
6.5
3
6.95
7.5
3
5.45
2.5
3
.
R1
2T
3.5
0.1
0.6
Mounting face
ø3.5
5
4-0.8
5
RDC502(Vertical type)
ø3.5
11.8
8
4
Mounting face
2.5
0.5
R5
.5
2
1T
2T
3T
(5)
11
0.8
0.1
(0.5)
(2)
(0.5)
(1.9)
467
RDC40
RDC50 Rotary Type
RDC90
■ Dimensions
Unit:mm
No.
Photo
Style
Mounting face
Mounting face
RDC503(Reflow type)
ø3.5
ø3.5
2.5
5
1T
RDC503
(Reflow type, V3.5 dia with radius)
11
5
11
4-ø1
4-ø1
8.2
8.2
6.5
6.5
3
7.5
7.5
3
6.7
6.7
5
1T
2.75
2.75
0.8
0.8
0.1
0.1
2T
R5
.
R5 5
.5
2.5
2T
3T
3T
2T
2T
5
Mounting
face
Mounting
face
ø3.5
ø3.5
0.10.1
2.75
2.75
0.80.8
3
7.5 3
7.5
6.5
6.5
6
4-ø1
4-ø1
8.2
8.2
5 5
1111
2T2T
3T3T
RDC506(Reflow type, low-profile)
Mounting face
Mounting face
2.2
2.2
R5.5
R5.5
0.8
0.8
5
5
11
11
1.2
1.2
3T
3T
RDC90(Reflow type, Long-life)
Mounting face
ø3.5
0.2
2.5
6.7
Dummy
8
11
Circuit Diagram
RDC50 / RDC90
3T
CW
1T
3T
1T
2T
2.0
7.0
8.2
8.8
T2
CCW
ø6.5
3.2
新規外形図入る
(RDC90)
T1
RDC40
8.5
8.5
ø1.0
1T
1T
2T
2T
6.7
R1.5
R1.5
2-ø1
2-ø1
8.2
8.2
6.5
6.5
7
5.5
5.5
ø5
ø5
3
3
6.7
6.7
ø4
ø4
2T
2T
5 5
2T
5- 0.8
T3
0.8
Hole depth1.1
4.1
Resistive
Position Sensors
6.7
6.7
2.5
2.5
R5
R5.5
.5
.3
R1.3
R1
2T2T
1T1T
468
5
8.0
Resistive Position Sensors / Product Specifications
Method for Regulating the Linearity
Model RDC80
55
00
00
180˚(phase difference)
100
±165˚
50
0
±165˚
13 rotations
rotations
13
Model RDC50 / RDC90 / RD6R1A / RDCC0
0˚
center
Model RDC10 / RD7
With rated voltage applied between terminals 1 and 3, the straight line which
connects the measured output values VB and VA at specified reference positions
B and A is assumed to be an ideal straight line, so that deviation against the ideal
straight line when the voltage applied between terminals 1 and 3 is assumed to be
100% can be expressed as a percentage.
C
1. Reference taper:100%/A
2. Index point is 50% output point(RDC50/RDC90/RDCC0)
The center is in the configuration diagram condition
100
VA
50
0
Series
RDC50
RDC90
RD6R1A
RDCC0
Position B
Position A
(Mecha stroke)
0˚
B
VB
B
A
B
C
333.3°
±160°
±2%
80°
±30°
260°
±122°
320°
±155°
±2%
30°
±15°
±2%
A
Resistive
Position Sensors
Output voltage ratio(%)
2T output
4T output
±3%
Output voltage ratio(%)
100
100
VA
VA
1. Reference taper : 100% / 340˚
2. The center is in the configuration diagram condition
±3%
1. Reference
Reference taper
taper :: 90%/13rotations
90%/13rotations
1.
2. VA
VA is
is measured
measured output
output value
value
2.
±1%
±1%
Output
Output voltage
voltage ratio(%)
ratio(%)
Model RDC40
±3%
Resistive Position Sensors / Measurement and Test Methods
Resistive Position Sensor
〔Total Resistance〕
The total resistance, with the shaft(lever)placed at the end of terminal 1 or 3, shall be determined by
measuring the resistance between the resistor terminals 1 and 3 unless otherwise specified.
〔Rating Voltage〕
The rating voltage corresponding to the rated power shall be determined by the following equation. When the
resulting rated voltage exceeds the maximum operating voltage of a specific resistor, the maximum operating
voltage shall be taken as the rated voltage.
E=√ P・R
E:Rated voltage(V)
P:Rated power(W)
R:Total nominal resistance(Ω)
477
Resistive Position Sensors
List of Varieties
Type
Rotary Type
Series
RDC40
RDC50
Magnetic Rotary Type
RDC90
RDC80
RD6R1A
RDCC0
NEW
Photo
Resistive
Position Sensors
Direction of lever
Horizontal
Vertical
Horizontal
Effective electrical angle(°)
5,400
(15 rotations)
333.3
80, 260
340(1-phase)
360(2-phase)
320
30
Linearity guarantee range(°)
4,680
(13 rotations)
320
60, 244
330(1-phase)
360(2-phase)
310
±15
Travel
ー
ー
ー
ー
ー
ー
Operating temperature range
−30℃ to +80℃
−40℃ to +85℃
0℃ to +50℃
Operating life
100,000 cycles
1,000,000 cycles
10,000,000
cycles
100,000 cycles
500,000 cycles
10,000,000
cycles
Available for automotive use
●
●
●
●
●
ー
Operating force
ー
ー
ー
ー
ー
ー
Rotational torque
1.96mN・m max.
10mN・m max.
100mN・m
5mN・m max.
±20%
ー
±2 (320°
)
±2
Vertical
−40℃ to +120℃
Life cycle (availability)
Mechanical
performance
2mN・m max.
Total resistance
tolerance
Electrical
performance
Linearity(%)
±30%
±1
±2
±3
Rated voltage
(V DC)
Environmental
performance
5
Cold
−30℃ 240h
Dry heat
80℃ 240h
120℃ 168h
Damp heat
60℃,
90 to 95%RH 240h
60℃, 90 to 95%RH 96h
Terminal style
Page
Connector
−40℃ 168h
Insertion / Reflow
466
−40℃ 240h
85℃ 168h
85℃ 240h
80℃,
60℃,
90 to 95%RH 96h 90 to 95%RH 240h
Reflow
Connector
469
470
471
Resistive Position Sensors Measurement and Test Methods・ ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 477
Resistive Position Sensors Soldering Conditions・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 478
Resistive Position Sensors Cautions・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 479
Note
● Indicates applicability to all products in the series.
464
Resistive Position Sensors / Soldering Conditions
Reference for Manual Soldering
Series
Tip temperature
Soldering time
350±5℃
3+10 s
350℃ max.
3s max.
RDC50, RDC90, RDC80
RDC10, RD7
Reference for Dip Soldering
Preheating
Series
Soldering surface
temperature
RDC501, RDC502
Dip soldering
No. of solders
Heating time
Soldering
temperature
Soldering time
100 to 150℃
1minute max.
260±5℃
10±1s
1 time
100℃ max.
1minute max.
260℃ max.
5s max.
1 time
RD7
Example of Reflow Soldering Condition
Cleaning Cleaning should not be attempted.
Type of solder to be used Use cream solder that contains 10 to 15 %wt flux.
Number of solder applications - apply solder only once
Recommended reflow conditions
Resistive
Position Sensors
Temperature(℃)
1.
2.
3.
4.
300
A
B
200
C
D
100
Room
temperature
Time(s)
Pre-heating
E max.
G max.
H max.
F max.
I max.
A
B
C
D
E
F
G
H
I
No. of
reflows
RDC503
RDC506
250℃
230℃
180℃
150℃
2min.
ー
5s
40s
4min.
1 time
RDC90
255℃
230℃
ー
ー
ー
2min.
10s
1min.
4min.
1 time
RDC80
250℃
ー
180℃
150℃
90±30s
ー
10±1s
ー
ー
1 time
Series
Notes
1. When using an infrared reflow oven, solder may not always be applied as intended.
Be sure to use a hot air reflow oven or a type that uses infrared rays in combination with hot air.
2. The temperatures given above are the maximum temperatures at the terminals of the sensor when employing a hot air
reflow method. The temperature of the PC board and the surface temperature of the sensor may vary greatly depending
on the PC board material, its size and thickness. Ensure that the surface temperature of the sensor does not rise to 250℃
or greater.
3. Conditions vary to some extent depending on the type of reflow bath used. Be sure to give due consideration to this prior to use.
478