ELN60 6 0 W S i n g l e O u t put Class 2 Switching Power Supply series Universal AC input / Full range Fully isolated plastic case with IP64 level Built-in constant current limiting circuit with adjustable OCP level Protections: Short circuit / Overload / Over voltage UL1310 Class 2 power unit Cooling by free air convection Suitable for LED lighting and moving sign applications IP64 design for indoor or outdoor installations Optional Dimmer Functions: 1.1~10VDC or PWM Controlled Model Number Output Volts Output Amps Efficiency OVP Ripple & Noise O/P Adjust LED Oper Voltage 9 Volts(DC) 12 Volts(DC) 15 Volts(DC) 24 Volts(DC) 27 Volts(DC) 48 Volts(DC) 120 mV pk-pk 120 mV pk-pk 150 mV pk-pk 150 mV pk-pk 200 mV pk-pk 250 mV pk-pk 3~9Volts 3~12Volts 3~15Volts 3~24Volts 3~27Volts 3~48Volts SINGLE OUTPUT *ELN60-9 (D or P) *ELN60-12 (D or P) *ELN60-15 (D or P) *ELN60-24 (D or P) *ELN60-27 (D or P) *ELN60-48 (D or P) 5 Amps 5 Amps 4 Amps 2.5 Amps 2.3 Amps 1.3 Amps 82% 85% 86% 87% 87% 88% 11~13.5 Volts(DC) 13.8~16 Volts(DC) 17.5~21 Volts(DC) 28~32 Volts(DC) 31~35 Volts(DC) 54~60 Volts(DC) 8.7~10.5 Volts(DC) 10.8~13.2 Volts(DC) 13.5~16.5 Volts(DC) 21.6~26.4 Volts(DC) 24.3~29.7 Volts(DC) 43.2~52.8 Volts(DC) * Note: The Asterisk * denotes a choice of receiving this product WITH a Dimmer Control Feature. There are 2 types of dimmer Control: 1. 1.1~10VDC Control (“D” Type) 2. PWM Control (“P” Type) See page 5 of this specification To receive this product with the 1.1~10VDC Dimmer Control feature, simply add the letter “D” to the end of the model number (i.e. “ELN60-9D”). To receive this product with the PWM Dimmer Control feature, simply add the letter “P” to the end of the model number (i.e. “ELN60-9P”). If not specified, you will receive the NON Dimmer Control product ((i.e. “ELN60-9”). WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 ELN60 6 0 W S i n g l e O u t put Class 2 Switching Power Supply INPUT SPECIFICATIONS Input Voltage Range (Note 3) Frequency Range Input Current (115 / 230VAC) Inrush Current, max, Cold Start Leakage Current 90-264VAC 47-63 Hz 1.2 Amps / 0.7 Amps max 60Amps/230VAC 0.25mAmps/240VAC Efficiency Harmonic Current EMS Dimming Control (option) See Selection Chart EN61000-3-2,-3 EN61000-4-2,3,4,6,8,11; ENV50204; EN55024 light industry level, criteria A 1~10Volts(DC) or PWM signal: 100Hz~3KHz OUTPUT SPECIFICATIONS ENVIRONMENTAL SPECIFICATIONS Voltage and Current See Selection Chart Line Regulation ±1.0% Load Regulation ±2.0% Ripple/Noise (Note 1) See Selection Chart Over Voltage Protection See Selection Chart Shut down o/p voltage, re-power Over Current Protection 9~12Volts(DC) 95~110% 15~48Volts(DC) 130% max Constant current limiting, auto recov after fault condition is removed Voltage Tolerance (Note 2) ±5.0% Setup, Rise Time @ FL 500ms, 30ms/230VAC 1500ms, 30ms/115VAC Hold Up Time, typ @ FL 50ms/230VAC ; 16ms/115VAC DC Voltage Adjust (Note 4) See Selection Chart Can be adjusted by internal potential meter SVR1 Current Adjust Range -25%~3%. Can be adjusted by internal potential meter SVR2 LED Operation Voltage (Note 5) See Selection Chart Oper. Temperature Relative Humidity Storage Temperature MTBF (25°C) Temp. Coefficient Vibration GENERAL SPECIFICATIONS Safety EMI Isolation Resistance UL1310 Class 2, CAN/CSA C22.2 No. 223- -M91 (except for 48Volts); IP64 approved, design refer to TUV EN60950-1, EN61347-2-13 Compliance to EN55022(CISPR22) Class B 3 KVAC Input/Output I/P-O/P >100MΩ / 500VDC / 25°C70%RH All specifications are typical at nominal input, full load, and 25°C unless otherwise noted WWW.ASTRODYNE.COM series -20°C to +60°C (See Derate Curve) 20~90% RH non cond -40°C to +85°C, 10~95% RH 603KHrs min, MIL-HDBK-217F ±0.03%/°C (0~50°C) 10~500Hz, 2G 10min./1cycle, period for 60min.each along X,Y, Z axes PHYSICAL SPECIFICATIONS Size Millimeters / Inches 181 x61.5 x 35 / 7.13” x 2.42” x 1.38” Weight 14.11 oz (400g) Notes 1. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 2. Tolerance : includes set up tolerance, line regulation and load regulation. 3. Derating may be needed under low input voltage. Please check the derating curve for more details. 4. Output voltage can be adjusted through the SVR1 on the PCB ; limit of output constant current level can be adjusted through the SVR2 on the PCB. 5. Constant current operation region is within the specified output voltage range. This is the suitable operation region for LED related applications. Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 6 0 W S i n g l e O u t put Class 2 Switching Power Supply ELN60 series Mechanical Dimiension WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 6 0 W S i n g l e O u t put Class 2 Switching Power Supply WWW.ASTRODYNE.COM ELN60 series ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 6 0 W S i n g l e O u t put Class 2 Switching Power Supply WWW.ASTRODYNE.COM ELN60 series ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 6 0 W S i n g l e O u t put Class 2 Switching Power Supply WWW.ASTRODYNE.COM ELN60 series ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458