ELP25 2 5 W L E D D r i v e r with PFC series Universal Input to 305 VAC High Efficiency (Up to 84%) Active Power Factor Correction (typ 0.94) Constant Output Current Waterproof (IP66) All-Round Protection: OVP, SCP, OLP Complies with UL8750 & EN61347 Safety Regulations Optional Dimmer Control Feature Model Number Output Voltage Range Output Amps Range Efficiency @ 220Vin Over Voltage Protection *ELP25-1212(D or P) *ELP25-1214(D or P) *ELP25-1218(D or P) *ELP25-1224(D or P) *ELP25-1236(D or P) *ELP25-1240(D or P) *ELP25-1256(D or P) *ELP25-1272(D or P) 4-12Volts(DC) 5-14Volts(DC) 6-18Volts(DC) 8-24Volts(DC) 12-36Volts(DC) 13-40Volts(DC) 19-56Volts(DC) 24-72Volts(DC) 13~18 Volts(DC) 16~20 Volts(DC) 21~24 Volts(DC) 26~30 Volts(DC) 42~46 Volts(DC) 44~48 Volts(DC) 59~62 Volts(DC) 82~90 Volts(DC) 1.976-2.184 Amps 1.663-1.838 Amps 1.33-1.47 Amps 0.998-1.103 Amps 0.665-0.735 Amps 0.589-0.651 Amps 0.428-0.473 Amps 0.333-0.368 Amps 80% 80% 82% 82% 83% 83% 84% 84% * Note: The Asterisk * denotes a choice of receiving this product WITH a Dimmer Control Feature (D) or WITHOUT the Dimmer Control Feature (P). Simply add the letter “D” or “P” to the end of the model number (i.e. “ELP25-1212D” or “ELP25-1212P”) when ordering to receive the desired version. WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 ELP25 2 5 W L E D D r i v e r with PFC INPUT SPECIFICATIONS Input Voltage Range Frequency Range Input Current Inrush Current GENERAL SPECIFICATIONS 90-305VAC 47-63 Hz 0.32 Amps max @ 100VAC 0.15 Amps max @ 220VAC 20A @ 230VAC, 25°C Cold Start OUTPUT SPECIFICATIONS Voltage and Current Line Regulation Load Regulation Ripple/Noise Turn-on Delay Time Output Overshoot / Undershoot Over Voltage Protection Short Circuit Protection Over Load Protection series See Selection Chart 2.0% 5.0% 25% pk-pk / 20MHz bandwidth 0.1uF ceramic capacitor 10uF eletrolytic capacitor 1.7S @ 110VAC 10% When power on or off See Selection Chart Hiccup mode. Auto-Recover No damage shall occur when any output operating in a short circuit condition. The power supply shall self-recover when the fault condition is removed 125% of Po Hiccup mode. Auto-Recover Safety (Note 1) USA & Canada UL8750 Compliance to UL1310 Class 2, UL1012, UL935, CAN/CSA-C22.2 No. 0, CSA-C22.2 No. 107.1, CSA-C22.2 No. 250.0 CE Europe EN61347-1, EN61347-2-13 EMI EN55015 Efficiency See Selection Chart EMS Compliance to EN61000-4-2,3,4,6,8,11; EN61000-3-2,3 EN61547 No load Power Dissipation ≤5.0W ENVIRONMENTAL SPECIFICATIONS Oper. Temperature Storage Temperature MTBF Life Time -20°C to +70°C 10~100% RH (See Derate Curve) -40°C to +85°C, 5~100% RH 484KHrs min, min @ 80% Load, MIL-HDBK-217F (25°C) /110VAC 79K Hrs; 110VAC, 25°C, 80% Load PHYSICAL SPECIFICATIONS Size Millimeters 78 x 80 x 25 Inches 3.07” x 3.15” x 0.98” Weight 7.05 oz (200g) Note 1) 12-36 Volt outputs are Class 2 U.S. and Canada The 40 Volt output is Class 2 U.S. ONLY ALL others are NOT Class 2 All specifications are typical at nominal input, full load, and 25°C unless otherwise noted WWW.ASTRODYNE.COM Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 ELP25 2 5 W L E D D r i v e r with PFC series Derating Curves Derating Curve 100 100 80 80 Load(%) Load(%) Derating Curve 60 40 20 0 60 40 20 -20 -5 10 25 40 Ambient Temperature(°C) 55 70 0 90 120 150 180 210 240 270 300 330 Input Voltage(V) Mechanical Outline ELP25-xxxxP AC INPUT (2*AWG #18) WHITE (ACN) BLACK (ACL) DC OUTPUT (2*AWG #18) RED (V+) BLACK (V-) Unspecified tolerance: ±0.2 WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 ELP25 2 5 W L E D D r i v e r with PFC series ELP25-xxxxD AC INPUT (2*AWG #18) WHITE (ACN) BLACK (ACL) Dimming control wire (3*AWG #22) DC OUTPUT (2*AWG #18) YELLOW (10V OUTPUT) RED (V+) BLACK (V-) PURPLE (0~10V INPUT) GREEN (GND) Unspecified tolerance:±0.2 Dimming Control (On secondary side) Parameter Min. Typ. Max. 9.8 V 10 V 10.2 V 10V output source current -10 mA - 2 mA Absolute maximum voltage on the 0~10V input pin -2 V - 15 V Source current on 0~10V input pin 0 mA - 1 mA 10V output voltage Notes The dimmer control may be operated from either a potentiometer or from an input signal of 0 – 10 Vdc. Two recommended implementations are provided below. 100% 90% ELP25-xxxxD output current 80% 70% 60% 50% 40% 30% 20% 10% 0% 1V 2V 3V 4V 5V 6V 7V 8V 9V 10V Dimming control Implementation 1: Potentiometer Control WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 ELP25 2 5 W L E D D r i v e r with PFC series 100% 90% output current 80% ELP25-xxxxD 70% 60% 50% 40% 30% 20% 10% 0% 1V 2V 3V 4V 5V 6V 7V 8V 9V 10V DC Input Implementation 2: DC input Notes: 1. For the driver to operate properly, the load voltage must be maintained above the minimum voltage threshold (approx. 33% of the max. output voltage for any given model). 2. If the input voltage is within 90-175Vac, the output current can be varied from 100% down to 10%. (Refer to right figure) Output voltage(Vo) Vo Vo/3 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Output current(%) Io 3. If the input voltage is within 175-305Vac, the output current can be varied from 100% down to 20%. (Refer to right figure) Output voltage(Vo) Vo Vo/2 Vo/3 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% Io Output current(%) WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458