SP500 5 0 0 W S i n g l e O u t put with PFC Function series Universal AC input Protections:Short circuit/Over load/Over voltage/Over temperature Built-in active PFC function, PF >0.95 Forced air cooling by built-in DC Fan Built-in cooling Fan ON OFF control Built in remote ON-OFF control Built-in remote sense function Fixed switching fequency at 110KHz Model Number Output Volts Output Amps OVP 12 Volts(DC) 13.5 Volts(DC) 15 Volts(DC) 24 Volts(DC) 27 Volts(DC) 48 Volts(DC) 40 Amps 36 Amps 32 Amps 20 Amps 18 Amps 10 Amps 13.8 ~ 16.2Volt(DC) 15.75 ~ 18.2Volt(DC) 18 ~ 21Volt(DC) 27.6 ~ 32.4Volt(DC) 31 ~ 36.5Volt(DC) 57.6~ 67.2Volt(DC) Min Load DC Volt Adjust Efficiency SINGLE OUTPUT SP500-12 SP500-13.5 SP500-15 SP500-24 SP500-27 SP500-48 WWW.ASTRODYNE.COM 0~40Amps 0~36Amps 0~32Amps 0~20Amps 0~18Amps 0~10Amps 10~13.2Volt(DC) 12~15Volt(DC) 13.5~18Volt(DC 20~26.4Volt(DC) 24~30Volt(DC) 41~56Volt(DC) 84% 84% 83% 85.5% 86.5% 87% ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 SP500 5 0 0 W S i n g l e O u t put with PFC Function INPUT SPECIFICATIONS Input Voltage Range (Note 5) Frequency Range Inrush Current, typ: (cold start) Input Current Leakage current Min Load Power Factor @ FL 90 ~ 264VAC 124~370 Volts(DC) 47-63 Hz 18Amps/115VAC; 36Amps 230VAC 7.0Amps @ 115VAC 3.5 Amps @ 230VAC < 3.5mAmps / 240VAC See Selection Chart PF > 0.95 / 230VAC > 0.95 / 115VAC OUTPUT SPECIFICATIONS Voltage and Current (Note3) See Selection Chart Line Regulation ±0.5% Load Regulation ±0.5% Voltage Tolerance (Note 2) ±1.0% Ripple/Noise (Note 1) 240mVpk-pk: 12~24Volts(DC) 200mVpk-pk: 27Volts(DC) 300mVpk-pk: 48Volts(DC) Hold Up Time @ FL 24mS Setup, Rise Time @ FL 1500mS, 50mS Over Voltage Protection See Selection Chart Hiccup mode, auto-recover Over Current Protection 105~135% rated output power Fold back current limiting,auto recover Over Temperature (Note 3) 80°C TSW1: detect on heatsink of power transistor 90°C TSW2: detect on heatsink of power diode Shut down o/p voltage, auto recover DC Volt Adjust See Selection Chart Peak Load: 10min (Note 4 ) 10% max GENERAL SPECIFICATIONS Safety Insulation Resistance EMI Harmonic Current Remote Control Efficiency Isolation EMS Fan Control series RC+/RC-: short= Power on open= Power off See Selection Chart 3000VAC Input - Output 1500VAC Input - Ground 500VAC Output - Ground Compliance to EN61000-4-2,3,4,5,6,8,11 ENV50204, light Industry Level, Criteria A RTH1 or RTH2 ≥ 50°C Fan On, ≤ 45°C Fan Off, ≥ 70°C output shutdown ENVIRONMENTAL SPECIFICATIONS Oper. Temperature Storage Temperature Relative Humidity Temperature Coefficient MTBF Vibration -10°C to +50°C (See Derate Curve) -20°C to +85°C, 10~95% RH 20~90% RH non cond ±0.03% / °C (0-50°C) 133.4KHrs min,MIL-HDBK-217F(25°C) 10~500Hz, 2G10min./1cycle, period for 60min. each along X, Y, Z axes PHYSICAL SPECIFICATIONS Size Weight 170x120 x 93mm (6.69”x4.72 ”x3.66”) 67.02 oz (1900g) Note 1. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 2. Tolerance : includes set up tolerance, line regulation and load regulation. 3. Derating may be needed under low input voltages. Please check the derating curve for more details. UL60950-1, TUV EN60950-1 Approved ≥ 100MΩ / 500Volts(DC) Compliance to EN55022B (CISPR22B) Compliance to EN61000-3-2,-3 All specifications are typical at nominal input, full load, and 25°C unless otherwise noted WWW.ASTRODYNE.COM Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 5 0 0 W S i n g l e O u t put with PFC Function WWW.ASTRODYNE.COM SP500 series ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 5 0 0 W S i n g l e O u t put with PFC Function WWW.ASTRODYNE.COM SP500 series ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458