SP750 series

SP750
7 5 0 W S i n g l e O u t put with PFC Function
series
Universal AC input
Protections:Short circuit/Over load/Over voltage/Over
temperature
Built-in active PFC function, PF>0.96
Forced air cooling by built-in DC ball bearing fan
High power density of 5.48W/cubic inch
Built-in remote ON-OFF control
Built-in constant current limiting circuit
Built-in remote sense function
With power good and fail signal output
AC input active surge current limiting
Model Number
Output Volts
Output Amps
OVP
120 Amps
62.5 Amps
50 Amps
31.3 Amps
27.8 Amps
15.7 Amps
5.75 ~ 6.75Volt(DC)
13.8 ~ 16.2Volt(DC)
18 ~ 21Volt(DC)
27.6 ~ 32.4Volt(DC)
31 ~ 36.5Volt(DC)
57.6~ 67.2Volt(DC)
Min Load
DC Volt Adjust Line Reg
Efficiency
SINGLE OUTPUT
SP750-5
SP750-12
SP750-15
SP750-24
SP750-27
SP750-48
5 Volts(DC)
12 Volts(DC)
15 Volts(DC)
24 Volts(DC)
27 Volts(DC)
48 Volts(DC)
WWW.ASTRODYNE.COM
0~120Amps
0~62.5Amps
0~50Amps
0~31.3Amps
0~27.8Amps
0~15.7Amps
4.75~5.5Volt(DC)
10~13.5Volt(DC)
13.5~16.5Volt(DC)
22~26.4Volt(DC)
24~30Volt(DC)
43~56Volt(DC)
±0.5%
±0.3%
±0.3%
±0.2%
±0.2%
±0.2%
80%
85%
87%
89%
89%
90%
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
SP750
7 5 0 W S i n g l e O u t put with PFC Function
INPUT SPECIFICATIONS
Input Voltage Range
Frequency Range
Inrush Current, typ: (cold start)
Input Current
Leakage current
Min Load
Power Factor (typ.) @ FL
90 ~ 264VAC 127~370 Volts(DC)
47-63 Hz
27Amps/115VAC; 45Amps 230VAC
8.8Amps @ 115VAC
4.2 Amps @ 230VAC
< 2.0 mAmps / 240VAC
See Selection Chart
PF> 0.96 / 230VAC
> 0.99 / 115VAC
OUTPUT SPECIFICATIONS
Voltage and Current See Selection Chart
Line Regulation
See Selection Chart
Load Regulation
±0.5%: 12~48Volts(DC)
±2.0%: 5Volts(DC)
Voltage Tolerance (Note 2)
±1.0%: 12~48Volts(DC)
±2.0%: 5 Volts(DC)
Ripple/Noise (Note 1)
120mVpk-pk max
Hold Up Time @ FL
16mS /230VAC
16mS /115VAC
Setup, Rise Time @ FL
1500mS, 50mS /230VAC
1500mS, 50mS /115VAC
Over Voltage Protection
See Selection Chart
Shutdown o/p voltage, re-power
Over Current Protection
105~135% rated output power
Constant current limiting, unit will Hiccup after 3sec
Over Temperature Protection
85°C ±5°C (TSW1) detect on heatsink of power transitor
85°C ±5°C (TSW2) detect on heasink of power diode
Shutdown o/p volt, auto recover after cool down
DC Volt Adjust
See Selection Chart
series
EN55022(CISPR22) Class B
Harmonic Current
Compliance to EN61000-3-2,-3
Remote Control (Note 3)
RC+/RC-: short= Power on
Open= Power off
Power Good/Fail
50mS/1mS
Efficiency
See Selection Chart
Isolation
3000VAC Input - Output
1500VAC Input - Ground
500VAC Output - Ground
EMS
Compliance to
EN61000-4-2,3,4,5,6,8,11, ENV50204, ENV55024, EN61000-6-2 EN61204-3
heavy Industry Level, Criteria A
ENVIRONMENTAL SPECIFICATIONS
Oper. Temperature
Storage Temperature
Relative Humidity
Temperature Coefficient
MTBF
Vibration
-20°C to +60°C (See Derate Curve)
-40°C to +85°C, 10~95% RH
20~90% RH non cond
0.05% / °C (0-50°C) 124KHrs min,MIL-HDBK-217F(25°C)
10~500Hz, 2G10min./1cycle, period for 60min. each along X, Y, Z axes
PHYSICAL SPECIFICATIONS
Size
Weight
278x127 x 63.5mm (10.94”x5 ”x2.5”)
102.29 oz (2900g)
Note
1. Ripple & noise are measured at 20MHz of bandwidth by using a 12”
twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
2. Tolerance : includes set up tolerance, line regulation and load regulation.
3. The power supply unit will have no output if the shorting connector is
not assembled between RC+ & RC-.
GENERAL SPECIFICATIONS
Safety
Insulation Resistance
EMI
UL60950-1, TUV EN60950-1 Approved
≥ 100MΩ / 500Volts(DC)
Compliance to EN55011(CISPR11)
All specifications are typical at nominal input, full load, and 25°C unless otherwise noted
WWW.ASTRODYNE.COM
Astrodyne products are not authorized or warranteed for use
as critical components in life support systems, equipment used
in hazardous environments, nuclear controls systems, or other
mission-critical applications.
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
7 5 0 W S i n g l e O u t put with PFC Function
WWW.ASTRODYNE.COM
SP750
series
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
7 5 0 W S i n g l e O u t put with PFC Function
WWW.ASTRODYNE.COM
SP750
series
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
7 5 0 W S i n g l e O u t put with PFC Function
WWW.ASTRODYNE.COM
SP750
series
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458