1 3 0 W O p e n F r a me and U-Channel Medical Switchers with PFC PMMK130 series 130 Watts Output Power Single Outputs Universal 90-264VAC Input 5VDC to 48VDC Outputs 5656VDC Input to Output Isolation Active Power Factor Correction 3” x 5” x 1.4” Model Number Output V Output I max. Ripple & Noise Efficiency(min/nom) Capacitive Load SINGLE OUTPUT PMMK130S-5 (U)(-A) PMMK130S-12 (U)(-A) PMMK130S-15 (U)(-A) PMMK130S-24 (U)(-A) PMMK130S-28 (U)(-A) PMMK130S-36 (U)(-A) PMMK130S-48 (U)(-A) 5 VDC 12 VDC 15 VDC 24 VDC 28 VDC 36 VDC 48 VDC 22 Amps 10.8 Amps 8.7 Amps 5.4 Amps 4.6 Amps 3.6 Amps 2.7 Amps 100mV pk-pk 120mV pk-pk 120mV pk-pk 120mV pk-pk 120mV pk-pk 120mV pk-pk 120mV pk-pk 75% / 80% 80% / 82% 80% / 85% 82% / 85% 82% / 85% 82% / 85% 82% / 85% 10,000uF 26,800uF 22,000uF 28,000uF 16,800uF 1,950uF 7,800uF Note: 1. The PMMK130 Series is offered in an optional U-Channel Chassis as well as with optional 3.96mm pitch 5 and 10 Pin Input and Output connectors (open frame construction and screw terminals are standard respectively). Simply add a “U” at the end of the Model Number to recieve the U-Channel configuration or a “-A” to receive the pins, or both if both are desired. For example: The Model Number “PMMK130S-5U-A” represents a single output 5VDC U-Channel supply with 3.96 pitched pins (5 Input; 10 Output) . See the Mechanical Dimensions on pages 3 through 8 in this specification 2. All “U” options are not covered by UL Certification unless provided with more than 10 CFM forced air cooling applied 6-10cm above T1. 3. Derating curves acceptable up tp 40°C for UL certified products All specifications are typical at nominal input, full load, and 25°C unless otherwise noted * These are stress ratings. Exposure of the devices to any of these conditions may adversely affect long term reliability. Proper operation under conditions other than the standard operating conditions is neither warranteed nor implied. WWW.ASTRODYNE.COM Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 1 3 0 W O p e n F r a me and U-Channel Medical Switchers with PFC INPUT SPECIFICATIONS Input Voltage / Frequency Range Inrush Current, typ: Input Current Power Factor (cold start) Leakage Current 90-264VAC / 47-63 Hz 60A @ 230VAC Input * 2.3~0.8A (90-264VAC) PF > 0.96 @ 230VAC <0.3mA @ 264VAC, 50Hz See Selection Chart 130 Watts 1% 0.5% nom / 1% max 0.5% nom / 1% max See Selection Chart <4S, typ. 20mS, typ. 30mS, typ. Auto recovery * 130% max., Auto recovery * 150% max., Auto recovery * 10mS <10% of Nominal O/P VDC GENERAL SPECIFICATIONS Safety UL/cUL: UL-EU: CB: CE: Isolation (Note 3) Insulation Resistance EMI Efficiency series ENVIRONMENTAL SPECIFICATIONS OUTPUT SPECIFICATIONS Voltage and Current Maximum Output Power Preset Accuracy (Note 6) Line Regulation (Note 5) Load Regulation (20% to FL) Ripple/Noise (Notes 1,2,7) Turn On Hold Up Time Rise Time Short Circuit Protection Over Voltage Protection Over Current Protection Transient Response Over Shoot/Under Shoot PMMK130 ANSI/AAMI ES60601-1 3rd ed. CSA C22.2 No. 60601-1 3rd ed. EN60601-1 3rd ed. IEC60601-1 3rd ed. EN60601-1-2 5656VDC I/P - O/P * 2828 VDC I/P - GND * 707VDC O/P - GND * ≥ 20MΩ (500VDC, 1S I/P-O/P) CISPR EN55011 class B See Selection Chart Oper. Temperature (Note 4) Storage Temperature Relative Humidity EMS Harmonics: Fluctuations: ESD: RS: EFT: Surge: CS: Dips: MTBF Vibration Drop Test -10°C to +70°C (See Derate Curve) -25°C to +85°C 10 to +90%, non-cond * IEC61000-3-2 Class A IEC61000-3-3 IEC61000-4-2, 6KV Contact, 8KV Air IEC61000-4-3 FR: 80MHz-2.5GHz Field Strength: 3V/M IEC61000-4-4 2KV on AC Line IEC61000-4-5 1KV (L-L); 2KV (L, N-PE) IEC61000-4-6 3V (EMF) IEC61000-4-11 95% 250CY, 70% 25CY, 40% 5CY, 5% 0.5CY 197,000 Hrs min. MIL-HDBK-217F 4G Pk, 50~500Hz, 3 Axes, 30 min* Test Height 70cm * PHYSICAL SPECIFICATIONS Size Open Frame: U-Channel: Weight Open Frame: U-Channel: 76.2 x 127 x 35.5mm (3” x 5” x 1.4”) 127 x 80.4 x 38mm (5” x 3.17” x 1.50”) 10.25 oz (291g) 13.38 oz (380g) NOTES: 1. All measurements should be made directly at the terminals of the power supply. 2. Ripple and Noise depend upon output voltage a specified per particular model. 3. Isolation for up to 1min duration. 4. Specified for free-air convection cooling. 5. Line regulation measured from 90 - 264VAC/100VAC minimum required for full load start. 6. Preset accuracy measured at nominal load, 120VAC input. 7. O/P noise measured directly at pins/terminals @ nominal load, 0uF by pass and 47uF electrolytic, pk-pk@ 20MHz bandwidth. Special EMC Notice: The end application shall provide an earth ground connection for conducted & radiated emission performance. Astrodyne is not liable for the end application without extra earth connection to PMMK130S Open Frame Power Supply. WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 1 3 0 W O p e n F r a me and U-Channel Medical Switchers with PFC PMMK130 series MECHANICAL DIMENSIONS Open Frame (PMMK130S-xx) 5.00in 127mm .20in 5mm 4.55in 115.6mm .22in 5.7mm .14in 4_ 3.5mm Vo Vo 3.00in 76.2mm Vo 2.61in 66.2mm COM FG COM ACN COM ACL 1.3in 33mm .10in 2.5mm WWW.ASTRODYNE.COM Input connector : 3P / 8.25mm pitch TERMINAL BLOCK .06in 1.6mm ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 1 3 0 W O p e n F r a me and U-Channel Medical Switchers with PFC PMMK130 series MECHANICAL DIMENSIONS WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 1 3 0 W O p e n F r a me and U-Channel Medical Switchers with PFC PMMK130 series MECHANICAL DIMENSIONS - FAN PLACEMENT RECOMMENDATION WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 1 3 0 W O p e n F r a me and U-Channel Medical Switchers with PFC PMMK130 series MECHANICAL DIMENSIONS Open Frame (PMMK130S-xx-A) 5.00in 127mm 4.55in 115.6mm .20in 5mm .22in 5.7mm .14in 4_ 3.5mm 3.00in 76.2mm Vo Vo Vo Vo Vo COM COM COM COM COM 2.61in 66.2mm FG ACN ACL 1.4in 35.5mm 1.24in 31.4mm .10in 2.5mm WWW.ASTRODYNE.COM Input connector : 5P / 3.96mm pitch MOLEX 41791-0005 Output connector : 10P / 3.96mm pitch MOLEX 41791-0010 .06in 1.6mm ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 1 3 0 W O p e n F r a me and U-Channel Medical Switchers with PFC PMMK130 series MECHANICAL DIMENSIONS WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 1 3 0 W O p e n F r a me and U-Channel Medical Switchers with PFC PMMK130 series MECHANICAL DIMENSIONS - FAN PLACEMENT RECOMMENDATION WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 1 3 0 W O p e n F r a me and U-Channel Medical Switchers with PFC PMMK130 series DERATE CURVES WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 1 3 0 W O p e n F r a me and U-Channel Medical Switchers with PFC PMMK130 series DERATE CURVES WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458