PMK450 series - Power Supplies

PMK450
450 Wa t t E n c l o s ed and U -C hannel P ow er Su p p lie s with PFC
series
450 Watts Output Power
Single Output
Universal 90-264VAC Input
12VDC to 48VDC Output
4242VDC Input to Output Isolation
Active Power Factor Correction
5 Volt Standby Power
**Optional Current Share (CS) Capability
*Model Number
Output V
Output I
Line Reg
(nom/max)
SINGLE OUTPUT
PMK450S-12 U,E,D(-CS)
PMK450S-24 U,E,D(-CS)
PMK450S-36 U,E,D(-CS)
PMK450S-48 U,E,D(-CS)
12 VDC
24 VDC
36 VDC
48 VDC
37.5 Amps
18.75 Amps
12.5 Amps
9.375 Amps
0.3% / 1.0%
0.2% / 0.5%
0.1% / 0.5%
0.1% / 0.5%
Load Reg
(nom/max)
Ripple
& Noise
Efficiency
(min/nom)
0.3% / 1%
0.2% / 0.5%
0.1% / 0.5%
0.1% / 0.5%
120mV pk-pk
240mV pk-pk
360mV pk-pk
480mV pk-pk
77% / 85%
78% / 86%
79% / 86%
81% / 88%
*Available in a U-Channel Package (i.e. PMK450S-12U), an Enclosed Package (i.e. PMK450S-12E) or an Enclosed Package with a DIN Rail Clip
(i.e. PMK450S-12D)
** The PMK450S Series power supplies are available with current-sharing (CS) option for N+1 paralleling and redundant power applications. To
receive this option with your product simply add “-CS” to the end of the Model Number. For example PMK450S-12U-CS. Please see the application
note at the end of this specification for instructions on how to utilize.
WWW.ASTRODYNETDI.COM
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
PMK450
450 Wa t t E n c l o s ed and U -C hannel P ow er Su p p lie s with PFC
ENVIRONMENTAL SPECIFICATIONS
INPUT SPECIFICATIONS
Input Voltage Range
Frequency Range
Inrush Current, typ: (cold start)
Input Current (90Vin/264Vin)
Power Factor (Nom I/P, FL)
Leakage current
90-264VAC (100-240VAC Nom.)
47-63Hz (50-60 Hz Nom.)
30A at FL, 115VAC
60A at FL, 230VAC
7A / 2.5A max
0.95 min
Less than 3.5mA @ 240VAC, 50Hz
OUTPUT SPECIFICATIONS
Voltage and Current
5 Volt Standby (+5Vsb)
Preset Accuracy
Line Regulation (LL-HL)
Load Regulation (20%-FL)
DC Output Power
Ripple/Noise
Hold Up Time, typ.
Turn On Delay Time
Rise Time Short Curcuit Protection
Over Voltage Protection
Over Current Protection
Efficiency (without Oring Diode)
series
See Selection Chart
0~2.0A (See Page 9)
1%
See Selection Chart
See Selection Chart
450W, Max (See Derating Curve)
See Selection Chart
20MHz bandwidth with parallel
0.1uF ceramic capacitor
47uF eletrolytic capacitor
16mS at nominal input voltage range
< 4S
< 25mS @ 110 Vin
Auto-recovery*
130% (max) Auto-recovery*
150% (max) Auto-recovery*
See Selection Chart
PHYSICAL SPECIFICATIONS
Size (PMK450S-xxU)
Millimeters / Inches
203.2x 127x 38 / 8”x 5”x 1.5”
Size (PMK450S-xxE, D)
Millimeters / Inches
224.9x 127x 40 / 8.85”x 5”x 1.57”
Weight U-Bracket (PMK450S-xxU)
33.97 oz (963g)
Enclosed (PMK450S-xxE)
37.32 oz (1058g)
Enclosed w. DIN Clip (PMK450-xxD) 38 oz (1077g)
* These are stress ratings. Exposure of the devices to any of these conditions
may adversely affect long term reliability. Proper operation under conditions
other than the standard operating conditions is neither warranteed nor implied.
WWW.ASTRODYNETDI.COM
Oper. Temperature
Storage Temperature
Oper. Humidity
Storage Humidity
MTBF @ 25°C
Vibration*
Drop Test*
EMS
Harmonics
Fluctuations
ESD
RS
EFT
Surge
CS
DIPS
EMI
0°C to 70°C (See Derate Curve)
-40°C to 85°C
10 - 90% for nominal input range
Non-condensing
5 - 95%
100K Hrs min. MIL-HDBK-217F
4G’S pk, 50~500Hz, 3 AXES.30 Min
70 cm no damage
61000-3-2 Class D
61000-3-3
Contact 6KV Air 8KV
61000-4-2
FR: 80MHz-2.5GHz
Field Strength: 3V / M
61000-4-3
2KV on AC power line 61000-4-4
1KV (L-N) & 2KV (L-PE, N-PE)
61000-4-5
3V (EMF)
61000-4-6
95% 250Cy , 70% 25 Cy
40% 5Cy , 5% 0.5Cy 61000-4-11
CISPR/EN55011 Class B
GENERAL SPECIFICATIONS
Safety UL/cUL: UL-EU:
CE: CB: Over-Shoot and under shoot
Remote sense
Hi-pot test (60S max)
Insulation Resistance (I/P-O/P)
UL60950-1 2nd ed./
C22.2 60950-1 2nd ed.
EN60950-1 2nd ed.
EN60601-1-2
IEC60950-1 2nd ed. Less than 10% of nominal output
0.5V drop. max at terminals
4242VDC I/P - O/P
2121 VDC I/P - GND
707VDC O/P - GND
500VDC, 1S, ≥ 20MΩ
REMOTE SHUTDOWN
1. Open Collector, Logic “1”=On, “0”=Off. No termination with S/D pin to
maintain constant “On” operation.
All specifications are typical at nominal input, full load, and 25°C unless otherwise noted
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
PMK450
EELLEECCTTRRIICCAALL SSPPEECCIIFFIICCAATTIIOONN
AASSTTRROODDYYNNEE PPAACCIIFFIICC CCOORRPP
450 Wa t t E n c l o s ed and U -C hannel P ow er Su p p lie s with PFC
6.3 Mechanical specification
MECHANICAL DIMENSIONS
series
U-Bracket (PMK450S-xxU)
M3 hole size
Input connector:3P / 8.25 mm pitch terminal block
Output connector:7P / 8.25 mm pitch terminal block
WWW.ASTRODYNETDI.COM
Unit : mm
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
PMK450
RROODDYYNNEE PPAACCIIFFIICC CCOORRPP
ECCTTRRIICCAALL SSPPEECCIIFFIICCAATTIIOONN
450 Wa t t E n c l AoASSsTTed
and U -C hannel P ow er Su p p lie s withEELLEPFC
series
Enclosed with Fan (PMK450S-xxE):
M3 hole size
Input connector:3P / 8.25 mm pitch terminal block
Output connector:7P / 8.25 mm pitch terminal block
WWW.ASTRODYNETDI.COM
Unit : mm
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
PMK450
EELLEECCTTRRIICCAALL SSPPEECCIIFFIICCAATTIIOONN
AASSTTRROODDYYNNEE PPAACCIIFFIICC CCOORRPP
450 Wa t t E n c l o s ed and U -C hannel P ow er Su p p lie s with PFC
series
Din-rail with Fan (PMK450S-xxD):
M3 hole size
Input connector:3P / 8.25 mm pitch terminal block
Output connector:7P / 8.25 mm pitch terminal block
WWW.ASTRODYNETDI.COM
Unit : mm
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
EELLEECCTTRRIICCAALL SSPPEECCIIFFIICCAATTIIOONN
AASSTTRROODDYYNNEE PPAACCIIFFIICC CCOORRPP
450 Wa t 7.
t E nDerating
c l o s ed andCurve
U -C hannel P ow er Su p p lie s with PFC
PMK450
series
U-Bracket (PMK450S-xxU):
Ambient Temperature Derating Curve
2.
1. Convection air
Forced air cooling (30CFM air flow is required)
Static Characteristics: Input voltage vs. Output Loading
WWW.ASTRODYNETDI.COM
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
AALL SSPPEECCIIFFIICCAATTIIOONN
CCTTRRIICCPFC
OORRPP U -C hannel P ow er Su p p lieEEsLLEEwith
IICC CC
NNEnEcPPA
AASSTWa
450
lAoCCsIIFFed
and
TRROOtDDtYYE
PMK450
series
Diagram of external fan placement
U-Bracket (PMK450S-xxU):
WWW.ASTRODYNETDI.COM
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
PMK450
450 Wa t tASETnRcOlDoYsNed
and U -C hannel P ow er Su p p lie s withEELPFC
LEECCTTRRIICCAALL SSPPEECCIIFFIICCAATTIIOONN
ASTRODYNEE PPAACCIIFFIICC CCOORRPP
series
Enclosed & Din-rail (PMK450S-xxE/D):
Ambient Temperature Derating Curve
Static Characteristics (Input voltage vs. Output Loading)
WWW.ASTRODYNETDI.COM
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
capacitors and measured band-width with DC-20MHz.
*2. Regulation included line, temperature drift etc tolerance variation.
*3. Load regulation measured from 20% to Full load.
*4. The efficiency is defined without Oring Diode.
*5. All measurements should be made directly at the terminals of the power
supply.
450 Wa t t E n c l o*6.
s edAlland
U -C hannel typical
P ow er Su
p p lie sunless
with PFC
specifications
@ 25℃,
otherwise noted, at nominal line s e r i e s
PMK450
and load.
+5Vsb Standby Power:
5Vsb
PMK450S-xx
SPECIFICATION
Min
Nom
Max
DC OUTPUT VOLTAGE (V)
4.85
5
5.15
PRESET ACCURACY (%)
OUTPUT CURRENT (A)
1
0
1.0
2.0
O/P NOISE (P-P, mV) *1
75
REGULATION (%) *2
1
LOAD REGULATION (%) *3
1.0
2.0
+5Vsb is a standby output voltage that is always active whenever AC
power is present. +5Vsb supplies 1.0A current in normal operation and
is capable of withstanding maximum 10W (2 Amps) peak power for 10
seconds. +5Vsb provides a power source for circuits that must remain
operational when DC main output is in sleep/off state. +5Vsb over
current protection is built internal to its controller. 5Vsb OCP trip point is
set to be within 2.5A - 5A. 5Vsb OVP is clamp.
WWW.ASTRODYNETDI.COM
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
450 Wa t t E n c l o s ed and U -C hannel P ow er Su p p lie s with PFC
PMK450
series
Parallel Operation Instructions *
1.) Follow wiring diagram below
2.) No external oring diodes needed, oring diodes are built in with current share
option
3.) Keep wires as short as possible to avoid noise pickup
*Notes: Applications for increased power not to exceed 800 Watts
Parallel operation of PMK450 not recommended for Medical
Applications due to increased leakage current
WWW.ASTRODYNETDI.COM
2915