PWB P o w e r B l o c k M i c r o-Miniature Modular Switching Power Supplies series Single 5 Watt Outputs 3.3VDC to 24VDC Universal 90 to 264VAC Input 3,000VAC Input to Output Isolation -25 to +70°C Operation High Efficiency 2”L x 1”W x 0.6”H Model Number Output Voltage Output Amps Output Watts Size (inches) PWB-5000 PWB-5001 PWB-5002 PWB-5003 PWB-5005 3.3 VDC 5 VDC 12 VDC 15 VDC 24 VDC 1.25 1 0.42 0.33 0.23 4W 5W 5W 5W 5W 1 x 2 x 0.6 1 x 2 x 0.6 1 x 2 x 0.6 1 x 2 x 0.6 1 x 2 x 0.6 WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 PWB P o w e r B l o c k M i c r o-Miniature Modular Switching Power Supplies INPUT SPECIFICATIONS Input Voltage, Nominal Input Frequency Inrush Current GENERAL SPECIFICATIONS 90-264VAC Nominal: 100-240VAC 47-63 Hz, 50-60Hz Nom. 20A @ 100VAC, typ 40A @ 200VAC, typ OUTPUT SPECIFICATIONS Output Voltage/Current Initial Accuracy Load Regulation 20%-FL Line Regulation Temperature Coefficient Ripple/Noise(20Mhz BW) Overvoltage Protection Hold Up Time Short Circuit Protection OverTemp Protection Current Limit series See Specific Model +/-1%, typ 3.3V & 5V:+/-1%, typ 12V, 15V, & 24V:+/-0.5%, typ 3.3V & 5V:+/-1%, typ 12V, 15V, & 24V:+/-0.5%, typ +/-0.03%/°C 200-250mV Pk-Pk, typ Clamp, 130-150% * 30mS, typ Continuous * Latching, Recovering 130% typ,Self-Reset Foldback Input-Out Isolation Output-Ground Isolation Input-Ground Isolation Operating Frequency Efficiency (@ Full Load) Safety UL/cUL: UL-EU: CE: CB: 3000VAC 1000VAC 2500VAC 100 Khz, fixed, typ 75 - 80%, typ UL60950-1 2nd ed./ C22.2 60950-1 2nd ed. EN60950-1 2nd ed. EN60601-1-2 IEC60950-1 2nd ed. ENVIRONMENTAL SPECIFICATIONS Oper. Temperature Relative Humidity Storage Temperature MTBF -25 to +50°C FL Derate Linearly to 25%L @ 70°C 0-95%, Non-Condensing -25 to +71°C * 466,553 Hrs MIL-HDBK 217, Parts Count Method, 25°C, Ground Benign PHYSICAL SPECIFICATIONS Case Material Construction Weight All specifications are typical at nominal input, full load, and 25DegC unless otherwise noted * These are stress ratings. Exposure of the devices to any of these conditions may adversely affect long term reliability. Proper operation under conditions other than the standard operating conditions is neither warranteed nor implied. WWW.ASTRODYNE.COM Rynite, 94V-0 Rated Encapsulated, Soft Pot 1.5 oz (42g) Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 PWB P o w e r B l o c k M i c r o-Miniature Modular Switching Power Supplies series MECHANICAL SPECIFICATIONS ACL .80in 20.32mm BOTTOM VIEW ACN .10 2.63mm -Vout .40in 10.16mm +Vout .10in 2.54mm 1.80in 45.72mm .59in 15.24mm .31in 8mm 2.00in 50.8mm 1.01in 25.57mm WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 ASTRODYNE PACIFIC CORP. PWB P o w e r B l o c k M i c r o-Miniature Modular Switching Power Supplies series POWER BLOCK APPLICATION NOTES Output Noise EMI C1 = Electrolytic Capacitor Capacitance = 22uF - 220uF Voltage = Two times rated output voltage C1 = 0.22uF X Capacitor L1 = 3uH - 10uH C2, C3 = 220pF Y Capacitors C2 = Electrolytic Capacitor Capacitance = 22uF - 47uF Voltage = Two times rated output voltage Notes: The figure below ia a sample diagram to reduce Output Ripple and Noise. C3 = Ceramic Capacitor Capacitance = 0.01uF - 0.1uF Voltage = 50 volt Notes: The figure below ia a suggested diagram to reduce Electromagnetic Interference (EMI). L1 = 10mH - 30mH Common Mode, Choke The diagram above is a recommended circuit, only by trying true application can levels be measured. Inrush Current If desired, the use of a Choke, NTC or Inrush Current Limiter may be used to reduce the Inrush Current 1. The use of C1 alone may reduce noise to desired levels, if not use L1, C2 and C3 in addition to C1. 2. The figure above is a suggested circuit. Only by trying true application can levels be tested. WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458