SCP800 series

SCP800
800W P a r a l l e l ( N + 1) Wi t h P FC Func t i on
series
AC input 180~260VAC only
Protections:Short circuit/Over load/Over voltage/Over
temperature
PF> 0.98@ 230VAC
Built in remote sense function
Built-in remote ON-OFF control
Built-in power good signal output
Built-in parallel operation function(N+1)
Can adjust from 20~100% output voltage by external
control 1-5V
Forced air cooling by built-in DC fan
Model Number
Output Volts
SCP800-12
SCP800-24
12 Volts(DC)
24 Volts(DC)
SINGLE OUTPUT
WWW.ASTRODYNETDI.COM
Output Amps
66 Amps
33Amps
Min Load
0~66Amps
0~33Amps
Ripple & Noise Efficiency
120mVpk-pk
240mVpk-pk
84%
88%
Safety Model No.
800S-P012
800S-P024
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
SCP800
800W P a r a l l e l ( N + 1) Wi t h P FC Func t i on
INPUT SPECIFICATIONS
PHYSICAL SPECIFICATIONS
Input Voltage Range
180 ~ 260VAC; 260~370VDC
Frequency Range
47-63Hz
Inrush Current, max: (cold start) 60Amps/230VAC
Input Current
5.0Amps@230VAC
Leakage current
< 3.5mAmps / 240VAC
Min Load
See Selection Chart
Power Factor (typ.) @ FL
> 0.98/230VAC
Size
Weight
OUTPUT SPECIFICATIONS
Voltage and Current
See Selection Chart
Line Regulation
±0.5%
Load Regulation
±0.5%
Voltage Tolerance (Note 2)
±1.0%
Ripple/Noise (Note 1) See Selection Chart
Hold Up Time @ FL
12mS
Setup, Rise Time @ FL
800mS, 400mS
Over Voltage Protection
105~135% follow to output
set up point
Shutdown o/p voltage, re-power
Over Current Protection (Note3) 105~115% rated output power
Current limiting, delay shut
down o/p, re-power
Over Temperature Protection
> 100°C / measure by heat sink,near
transformer, Shutdown o/p voltage
auto-recover after cool down
DC Voltage Adjust
±0.3% typ. adjustment by potentiometer
20~100% adjustment by 1~5Volts(DC) external control
ENVIRONMENTAL SPECIFICATIONS
Oper. Temperature
Storage Temperature
Relative Humidity
Temperature Coefficient
MTBF
Vibration
series
290 x 120 x 68 mm (11.42”x 4.72”x 2.68”)
67.02 oz (1900g)
GENERAL SPECIFICATIONS
Safety
EMI
Harmonic Current
Efficiency
Isolation
EMS
Power Good Signal
Special Function
Cooling
UL60950-1,
TUV EN60950-1 Approved
Insulation Resistance
≥100MΩ/500Volts(DC)/25°C/70%RH
Compliance to EN55022A (CISPR22A)
Compliance to EN61000-3-2,-3
See Selection Chart
3000VAC Input - Output
1500VAC Input - Ground
500VAC Output - Ground
Compliance to
EN61000-4-2,3,4,5,6,8,11 ENV50204,
light Industry Level, Criteria A
Open collector of NPN transistor
DC Volt. Adjust, remote sensing, remote
control, parallel operation
By fan, >20% load or >50°C fan on
NOTE
1. Ripple & noise are measured at 20MHz of bandwidth by using a 12”
twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
2. Tolerance : includes set up tolerance, line regulation and load regulation.
3. Current limiting 3 times(1.5s,3.0s,5.0s)Then intelligent auto recovery
before shut down
-20°C to +65°C (See Derate Curve)
-20°C to +85°C, 10~95% RH
20~90% RH non cond
±0.04% / °C (0-50°C) 74.9KHrs min,MIL-HDBK-217F(25°C)
10~200Hz, 2G10min./1cycle, period for
60min. each along X, Y, Z axes
All specifications are typical at nominal input, full load, and 25°C unless otherwise noted
WWW.ASTRODYNETDI.COM
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
800W P a r a l l e l ( N + 1) Wi t h P FC Func t i on
WWW.ASTRODYNETDI.COM
SCP800
series
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
800W P a r a l l e l ( N + 1) Wi t h P FC Func t i on
WWW.ASTRODYNETDI.COM
SCP800
series
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458