SCP800 8 0 0 W P a r a l l e l ( N+1) With PFC Function series AC input 180~260VAC only Protections:Short circuit/Over load/Over voltage/Over temperature PF> 0.98@ 230VAC Built in remote sense function Built-in remote ON-OFF control Built-in power good signal output Built-in parallel operation function(N+1) Can adjust from 20~100% output voltage by external control 1-5V Forced air cooling by built-in DC fan Model Number Output Volts Output Amps Min Load Ripple & Noise Efficiency Safety Model No. SINGLE OUTPUT SCP800-9 SCP800-12 SCP800-15 SCP800-18 SCP800-24 SCP800-36 SCP800-48 SCP800-60 9 Volts(DC) 12 Volts(DC) 15 Volts(DC) 18 Volts(DC) 24 Volts(DC) 36 Volts(DC) 48 Volts(DC) 60 Volts(DC) WWW.ASTRODYNE.COM 88Amps 66 Amps 53 Amps 44.4 Amps 33Amps 22.2 Amps 16 Amps 13 Amps 0~88Amps 0~66Amps 0~53Amps 0~44.4Amps 0~33Amps 0~22.2Amps 0~16Amps 0~13Amps 90mVpk-pk 120mVpk-pk 150mVpk-pk 180mVpk-pk 240mVpk-pk 360mVpk-pk 480mVpk-pk 500mVpk-pk 83% 84% 85% 86% 88% 88% 89% 90% 800S-P009 800S-P012 800S-P015 800S-P018 800S-P024 800S-P036 800S-P048 800S-P060 ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 SCP800 8 0 0 W P a r a l l e l ( N+1) With PFC Function INPUT SPECIFICATIONS Input Voltage Range 180 ~ 260VAC 260~370 Volts(DC) Frequency Range 47-63Hz Inrush Current, max: (cold start) 60Amps/230VAC Input Current 5.0Amps@230VAC Leakage current < 3.5mAmps / 240VAC Min Load See Selection Chart Power Factor (typ.) @ FL > 0.98/230VAC OUTPUT SPECIFICATIONS Voltage and Current See Selection Chart Line Regulation ±0.5% Load Regulation ±1.0%: 9Volts(DC) ±0.5%: 12~60Volts(DC) Voltage Tolerance (Note 2) ±1.5%: 9Volts(DC) ±1.0%: 12~60Volts(DC) Ripple/Noise (Note 1) See Selection Chart Hold Up Time @ FL 12mS Setup, Rise Time @ FL 800mS, 400mS Over Voltage Protection 105~135% follow to output set up point Shutdown o/p voltage, re-power Over Current Protection (Note3) 105~115% rated output power Current limiting, delay shut down o/p, re-power Over Temperature Protection > 100°C / measure by heat sink,near transformer, Shutdown o/p voltage auto-recover after cool down DC Voltage Adjust ±0.3% typ. adjustment by potentiometer 20~100% adjustment by 1~5Volts(DC) external control GENERAL SPECIFICATIONS Safety Insulation Resistance UL60950-1, TUV EN60950-1 Approved ≥100MΩ/500Volts(DC)/25°C/70%RH All specifications are typical at nominal input, full load, and 25°C unless otherwise noted WWW.ASTRODYNE.COM EMI Harmonic Current Efficiency Isolation EMS Power Good Signal Special Function Cooling series Compliance to EN55022A (CISPR22A) Compliance to EN61000-3-2,-3 See Selection Chart 3000VAC Input - Output 1500VAC Input - Ground 500VAC Output - Ground Compliance to EN61000-4-2,3,4,5,6,8,11 ENV50204, light Industry Level, Criteria A Open collector of NPN transistor DC Volt. Adjust, remote sensing, remote control, parallel operation By fan, >20% load or >50°C fan on ENVIRONMENTAL SPECIFICATIONS Oper. Temperature Storage Temperature Relative Humidity Temperature Coefficient MTBF Vibration -20°C to +65°C (See Derate Curve) -20°C to +85°C, 10~95% RH 20~90% RH non cond ±0.04% / °C (0-50°C) 74.9KHrs min,MIL-HDBK-217F(25°C) 10~200Hz, 2G10min./1cycle, period for 60min. each along X, Y, Z axes PHYSICAL SPECIFICATIONS Size Weight 290 x 120 x 68 mm (11.42”x 4.72”x 2.68”) 67.02 oz (1900g) Note 1. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 2. Tolerance : includes set up tolerance, line regulation and load regulation. 3. Current limiting 3 times(1.5s,3.0s,5.0s)Then intelligent auto recovery before shut down Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 8 0 0 W P a r a l l e l ( N+1) With PFC Function WWW.ASTRODYNE.COM SCP800 series ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 8 0 0 W P a r a l l e l ( N+1) With PFC Function WWW.ASTRODYNE.COM SCP800 series ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458