SCP800 series

SCP800
8 0 0 W P a r a l l e l ( N+1) With PFC Function
series
AC input 180~260VAC only
Protections:Short circuit/Over load/Over voltage/Over
temperature
PF> 0.98@ 230VAC
Built in remote sense function
Built-in remote ON-OFF control
Built-in power good signal output
Built-in parallel operation function(N+1)
Can adjust from 20~100% output voltage by external
control 1-5V
Forced air cooling by built-in DC fan
Model Number
Output Volts
Output Amps
Min Load
Ripple & Noise Efficiency
Safety Model No.
SINGLE OUTPUT
SCP800-9
SCP800-12
SCP800-15
SCP800-18
SCP800-24
SCP800-36
SCP800-48
SCP800-60
9 Volts(DC)
12 Volts(DC)
15 Volts(DC)
18 Volts(DC)
24 Volts(DC)
36 Volts(DC)
48 Volts(DC)
60 Volts(DC)
WWW.ASTRODYNE.COM
88Amps
66 Amps
53 Amps
44.4 Amps
33Amps
22.2 Amps
16 Amps
13 Amps
0~88Amps
0~66Amps
0~53Amps
0~44.4Amps
0~33Amps
0~22.2Amps
0~16Amps
0~13Amps
90mVpk-pk
120mVpk-pk
150mVpk-pk
180mVpk-pk
240mVpk-pk
360mVpk-pk
480mVpk-pk
500mVpk-pk
83%
84%
85%
86%
88%
88%
89%
90%
800S-P009
800S-P012
800S-P015
800S-P018
800S-P024
800S-P036
800S-P048
800S-P060
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
SCP800
8 0 0 W P a r a l l e l ( N+1) With PFC Function
INPUT SPECIFICATIONS
Input Voltage Range
180 ~ 260VAC 260~370 Volts(DC)
Frequency Range
47-63Hz
Inrush Current, max: (cold start) 60Amps/230VAC
Input Current
5.0Amps@230VAC
Leakage current
< 3.5mAmps / 240VAC
Min Load
See Selection Chart
Power Factor (typ.) @ FL
> 0.98/230VAC
OUTPUT SPECIFICATIONS
Voltage and Current
See Selection Chart
Line Regulation
±0.5%
Load Regulation
±1.0%: 9Volts(DC)
±0.5%: 12~60Volts(DC)
Voltage Tolerance (Note 2)
±1.5%: 9Volts(DC)
±1.0%: 12~60Volts(DC)
Ripple/Noise (Note 1) See Selection Chart
Hold Up Time @ FL
12mS
Setup, Rise Time @ FL
800mS, 400mS
Over Voltage Protection
105~135% follow to output
set up point
Shutdown o/p voltage, re-power
Over Current Protection (Note3) 105~115% rated output power
Current limiting, delay shut
down o/p, re-power
Over Temperature Protection
> 100°C / measure by heat sink,near transformer, Shutdown o/p voltage
auto-recover after cool down
DC Voltage Adjust
±0.3% typ. adjustment by potentiometer
20~100% adjustment by 1~5Volts(DC) external control
GENERAL SPECIFICATIONS
Safety
Insulation Resistance
UL60950-1, TUV EN60950-1 Approved
≥100MΩ/500Volts(DC)/25°C/70%RH
All specifications are typical at nominal input, full load, and 25°C unless otherwise noted
WWW.ASTRODYNE.COM
EMI
Harmonic Current
Efficiency
Isolation
EMS
Power Good Signal
Special Function
Cooling
series
Compliance to EN55022A (CISPR22A)
Compliance to EN61000-3-2,-3
See Selection Chart
3000VAC Input - Output
1500VAC Input - Ground
500VAC Output - Ground
Compliance to
EN61000-4-2,3,4,5,6,8,11
ENV50204,
light Industry Level, Criteria A
Open collector of NPN transistor
DC Volt. Adjust, remote sensing, remote
control, parallel operation
By fan, >20% load or >50°C fan on
ENVIRONMENTAL SPECIFICATIONS
Oper. Temperature
Storage Temperature
Relative Humidity
Temperature Coefficient
MTBF
Vibration
-20°C to +65°C (See Derate Curve)
-20°C to +85°C, 10~95% RH
20~90% RH non cond
±0.04% / °C (0-50°C) 74.9KHrs min,MIL-HDBK-217F(25°C)
10~200Hz, 2G10min./1cycle, period for 60min. each along X, Y, Z axes
PHYSICAL SPECIFICATIONS
Size
Weight
290 x 120 x 68 mm (11.42”x 4.72”x 2.68”)
67.02 oz (1900g)
Note
1. Ripple & noise are measured at 20MHz of bandwidth by using a 12”
twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
2. Tolerance : includes set up tolerance, line regulation and load regulation.
3. Current limiting 3 times(1.5s,3.0s,5.0s)Then intelligent auto recovery
before shut down
Astrodyne products are not authorized or warranteed for use
as critical components in life support systems, equipment used
in hazardous environments, nuclear controls systems, or other
mission-critical applications.
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
8 0 0 W P a r a l l e l ( N+1) With PFC Function
WWW.ASTRODYNE.COM
SCP800
series
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
8 0 0 W P a r a l l e l ( N+1) With PFC Function
WWW.ASTRODYNE.COM
SCP800
series
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458