OLP48 series - Power Supplies

OLP48
48W S i n g l e Ou t p ut C ons t ant C urrent LE D Po we r Su p p ly
series
Constant Current Operation Design to Eliminate LED
Drivers
UL8750
Universal AC Input of 90-264VAC
Built-In Active PFC Function ≥0.9 @ 100-230VAC
Compliance to EN61000-3-2 Class C
Adjustable OCP Level
Auto Recovery Protections: Short Circuit/Overload/
Over Voltage
No Minimum Load Rquirement
Cooling by Free Air Convection
Suitable for LED Lighting
High Reliability, 150,000 Hours MTBF
Output
Model Number Voltage
Output
Amps
Efficiency (typ) OVP
Ripple
& Noise
Current Adjust Constant Current
Region Vout Range
4 A
2 A
1 A
82%
86%
87%
2.0V pk-pk
3.0V pk-pk
4.8V pk-pk
2.8~4.0Amps
1.4~2.0Amps
0.7-1.0Amps
7.4~12Volts
15~24Volts
33~48Volts
SINGLE OUTPUT
OLP48-12
OLP48-24
OLP48-48
12 VDC
24 VDC
48 VDC
14.4~17 VDC
28.8~34 VDC
57.6~68 VDC
All specifications are typical at nominal input, full load, and 25°C unless
otherwise noted
WWW.ASTRODYNETDI.COM
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
OLP48
48W S i n g l e Ou t p ut C ons t ant C urrent LE D Po we r Su p p ly
INPUT SPECIFICATIONS
GENERAL SPECIFICATIONS
Input Voltage Range (Note 8)
90-264VAC
Frequency Range
47-63 Hz
Input Current (115/230 VAC)
0.8A/0.4A
Inrush Current (115/230VAC) 30/60A Cold Start, max.
Leakage Current (Safety Class II) <0.25mA@240VAC, 50Hz Power Factor
>0.9 at Full Load, 100-230VAC
Safety UL/cUL: UL-EU:
CE: CB: EMI Compliance
Isolation (I/P-O/P) *
Isolation Resistance, (I/P-O/P)
Efficiency (Note 4)
EMS
Harmonics
ESD RS
EFT
Surge
CS
DIPS
Vibration *
Drop Test *
OUTPUT SPECIFICATIONS
Voltage and Current (Note 3)
See Selection Chart
Line Regulation (Note 5 & 6)
±1%
Load Regulation (Note 5 & 7)
±2%
Ripple/Noise (Note 1 & 3)
See Selection Chart
Over Voltage Protection *
See Selection Chart
Shut down Latch Mode, re-power
Over Current Protection *
Hiccup mode, auto recovery
after fault condition is removed
Short Circuit *
Hiccup mode, auto recovery
after fault condition is removed
Turn On Delay Time
<2S
Current Adjust Range (Note 2) See Selection Chart
Constant Current Region (Note 2) See Selection Chart
Over Shoot/Under Shoot
<10% nominal voltage, 100-240VAC
ENVIRONMENTAL SPECIFICATIONS
Oper. Temperature
Relative Humidity
Storage Temperature
MTBF
Temp. Coefficient -30°C to +80°C (See Derate Curve)
20~90% RH non cond
30°C to +85°C, 0~95% RH
150KHrs min, MIL-HDBK-217F
(25°C) Parts Count Method
±0.03%/°C (0~50°C)
PHYSICAL SPECIFICATIONS
Size (H x W x L)
Weight
1.34”x1.86”x4”(34 x 47 x 101.6 mm)
4.8 oz (136g)
* These are stress ratings. Exposure of the devices to any of these conditions
series
UL8750, UL60950-1 2nd ed./
C22.2 60950-1 2nd ed.
EN60950-1 2nd ed.
EN60601-1-2
IEC60950-1 2nd ed. FCC Part 18 Class B & CISPR
EN55015 Class B for Lighting
Device; CISPR EN55022 Class B
3KVAC (4242VDC), 60S
>100MΩ / 500VDC @ 1S 25°C
See Selection Chart
Compliance to EN61000-3-2 Class C
61000-4-2, Contact 6KV, Air 8KV, FR: 80MHz-2.5GHz
61000-4-3, Field Strength: 3V/M
61000-4-4, 2kV on AC power Line
61000-4-5, 1kV (L-N) 61000-4-6, 3V (EFM)
61000-4-11, 95% 250Cy, 70% 25Cy,
40% 5Cy, 5% 0.5Cy, Applicable for
240VAC
2G ‘s peak, 10~500Hz, 3 AXES, Period 30 Min each along X,Y,Z axes
70 cm no damage / carton package
NOTES
1. Ripple & noise are measured at 20MHz of bandwidth by using a 12”
twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor
2. Constant current adjustable from 70-100% by trim pot
3. All measurements should be made directly at the output terminals.
Operation outside the specified constant current range may cause hic-up
resulting in LED blinking or LED dimming
4. Efficiency is measured at 100-240VAC input incorporated with a
constant load.
5. Load/Line regulation measures constant current accuracy
6. 100-240VAC Input, CC set @ 90% Load
7. Set CC between 65%-95% load
8. Derating may be needed at low input voltage. Please check the
derating curve for more details.
may adversely affect long term reliability. Proper operation under conditions
other than the standard operating conditions is neither warranteed nor implied.
WWW.ASTRODYNETDI.COM
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
48W S i n g l e Ou t p ut C ons t ant C urrent LE D Po we r Su p p ly
OLP48
series
OUTPUT POWER DERATING
Temperature Derating
a. -30°C~60°C: No derating required
b. Derate linearly 2%/°C from 60°C to 80°C at 100-265VAC input
See Curve Below
Input Voltage Derating
c. Input voltage vs. operating temperature: Derate maximum output by 5 watts for input voltage 90-100VAC when operating temperature is >50°C
Derating Curve
-30 0 10
Ambient (°C)
Temperature Derating
Input Voltage Derating
WWW.ASTRODYNETDI.COM
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
48W S i n g l e Ou t p ut C ons t ant C urrent LE D Po we r Su p p ly
OLP48
series
EFFICIENCY CURVE
POWER LOSS CURVE
WWW.ASTRODYNETDI.COM
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
48W S i n g l e Ou t p ut C ons t ant C urrent LE D Po we r Su p p ly
OLP48
series
LED DRIVING METHODS CURVE
WWW.ASTRODYNETDI.COM
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
48W S i n g l e Ou t p ut C ons t ant C urrent LE D Po we r Su p p ly
WWW.ASTRODYNETDI.COM
OLP48
series
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
48W S i n g l e Ou t p ut C ons t ant C urrent LE D Po we r Su p p ly
OLP48
series
APPLICATION INFORMATION
WWW.ASTRODYNETDI.COM
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
48W S i n g l e Ou t p ut C ons t ant C urrent LE D Po we r Su p p ly
OLP48
series
MECHANICAL SPECIFICATION
HS1
HS2
JST B3P-VH
JST SVH-21-P1.1
JST B3P-VH
JST SVH-21-P1.1
WWW.ASTRODYNETDI.COM
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458