PMMK320E series

3 2 0 Wa t t M e d i c a l Grade Switching Power Supply with PFC
PMMK320E
series
320 Watts Output Power
Single Outputs
Universal 90-264VAC Input
5VDC to 48VDC Outputs
5656VDC Input to Output Isolation
Active Power Factor Correction
3.86”W x 8.03”L x 1.57”H
Model Number
Output Voltage
Output Amps (max) Ripple & Noise max. Efficiency
SINGLE OUTPUT
PMMK320S-5E
PMMK320S-12E
PMMK320S-15E
PMMK320S-24E
PMMK320S-36E
PMMK320S-48E
5 VDC
12 VDC
15 VDC
24 VDC
36 VDC
48 VDC
60
26.7
21.4
13.4
8.9
6.7
71%
77%
79%
79%
81%
81%
Astrodyne products are not authorized or warranteed for use
as critical components in life support systems, equipment used
in hazardous environments, nuclear controls systems, or other
mission-critical applications.
WWW.ASTRODYNE.COM
100mV pk-pk
120mV pk-pk
150mV pk-pk
150mV pk-pk
150mV pk-pk
150mV pk-pk
All specifications are typical at nominal input, full load, and 25°C unless otherwise noted
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
3 2 0 Wa t t M e d i c a l Grade Switching Power Supply with PFC
90-264 VAC; Nom: 100-240VAC
47-63 Hz
0.95, min. Nom I/P, FL
30A @ 115VAC Cold Start, FL*
60A @ 230VAC Cold Start, FL*
5.4 Amps max., 90V I/P
1.8 Amps max., 264V I/P
<0.3mA, 240Vin, 50Hz
Isolation (Note 2)
Insulation Resistance
Efficiency (FL. Nom I/P)
Safety UL/cUL: UL-EU: CB: CE: See Selection Chart
±1%, max.
±1~1.5%, max.
±1%, typ (2% 5 Vout)
See Selection Chart
130% max. Auto Recovery *
160% max. Auto Recovery *
Auto Recover after fault
condition is removed *
<4S
<25mS, typ (Nom I/P, FL)
20mS, typ (Nom I/P, FL)
<10% of Nominal Output
Compensates for up to 0.5V drop
Open Collector, Logic “1” = ON
“0” = Off. No Termination necessary
to maintain constant “On” operation
ENVIRONMENTAL SPECIFICATIONS
OUTPUT SPECIFICATIONS
Voltage and Current Line Regulation (LL-HL)
Load Regulation 10%-FL
Preset Accuracy (Note 3)
Ripple/Noise (Notes 1, & 4)
Over Voltage Protection
Over Current Protection
Short Circuit Protection
Turn On Delay Time
Rise Time Hold Up Time
Over-Shoot/Under Shoot
Remote Sense
Remote Shutdown
PHYSICAL SPECIFICATIONS
Size
Construction
Weight
series
GENERAL SPECIFICATIONS
INPUT SPECIFICATIONS
Input Voltage Range
Frequency Range
Power Factor Correction
Inrush Current, typ:
Input Current
Leakage Current
PMMK320E
8.03”(L) x 3.86”(W) x 1.57”(H)
Enclosed
1.75 lb, (794g)
* These are stress ratings. Exposure of the devices to any of these conditions
may adversely affect long term reliability. Proper operation under conditions
other than the standard operating conditions is neither warranteed nor implied.
WWW.ASTRODYNE.COM
I/P-O/P: 5656VDC
I/P-Ground: 2121VDC
O/P-Ground: 707VDC
≥20MΩ
See Selection Chart
ANSI/AAMI ES60601-1 3rd ed.
CSA C22.2 No. 60601-1 3rd ed.
EN60601-1 3rd ed.
IEC60601-1 3rd ed.
EN60601-1-2
Oper. Temperature
-20 to +70°C (See Derate Curve)
Storage Temperature
-25 to +85°C *
Relative Humidity
10% to +90%, *
Storage: 5-95%
EMS
Harmonics
Class D, 61000-3-2
Fluctuations
61000-3-3
ESD 61000-4-2
RS
61000-4-3
EFT
61000-4-4
Surge
61000-4-5
CS
61000-4-6
MS
61000-4-8
DIPS
61000-4-11
EMI
EN55022 Class B
MTBF Mil Std 217F, 25°C
65,000 Hrs, min.
Vibration
4G Peak, 50-500Hz, 3 Axes
Drop Test
70 CM
NOTES
1. All measurements should be made directly at the terminals of the power supply
2. Isolation for up to 1 minute duration.
3. Preset Accuracy measured at nominal load, 120VAC input.
4. O/P Noise measured directly at the pins/terminals at nominal load, 0.1uF ceramic bypass and 47uF electrolytic, pk-pk @ 20MHz
bandwidth.
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
PMMK320E
3 2 0 Wa t t M e d i c a l Grade Switching Power Supply with PFC
series
MECHANICAL DIMENSIONS
2.00
50.8
M3 hole size
.93
23.6
.50
12.7
5.95
151.1
.94
23.9
4.33
110
1.57
40
.83
21
1.50
38
7.01
178
FG
ACN
ACL
+Vo(5V)
COM
COM
COM
+Vo
+Vo
3.86
98
-S
+S
S/D
GND
8.03
203.9
UNITS:mm (in)
WWW.ASTRODYNE.COM
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL
ANGULAR: MACH
BEND
TWO PLACE DECIMAL
THREE PLACE DECIMAL
MATERIAL
NAME
DRAWN
CHECKED
ENG APPR.
MFG APPR.
Q.A.
COMMENTS:
DATE
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
PMMK320E
ASTRODYNE PACIFIC CORP
ELECTRICAL SPECIFICATION
N
NEE PPAACCIIFSwitching
FIICC CCO
ORRPP Power Supply with PFCEELLEECCTTRRIICCAALL SSPPEECCIIFFIICCAATTIIO
ON
N
3 2 0 Wa t t MAeASSdTTiRRcOO
aDDl YYGrade
7. Derating
OUTPUT DERATING
CURVE
series
Curve
120%
Load(%)
100%
80%
60%
40%
20%
0%
-20℃ -10℃
℃
10℃
20℃
30℃
40℃
50℃
60℃
70℃
Ambient (℃)
Input voltage (VAC) 60Hz
Ta=25℃
1. 5V
2. 12、15、24、36、48V
WWW.ASTRODYNE.COM
1313
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458