WSL 600 SERIES, 60 WATTS

WSL 600 SERIES, 60 WATTS
HIGH EFFICIENCY, COMPACT DESIGN SWITCHMODE TECHNOLOGY
L-CASE
UL, cUL, TUV Certified CE marked for European Compliance CEC /
DOE EISA 2007 Compliant
CF Version in UL File 3rd Edition
MODEL NUMBER
CF LOW LEAKAGE
(Y = YES)
Standard Specifications
VDC
AMPS
WATTS
WSL650
5
8
40
WSL655
5.5
7.6
42
WSL660
6
7.1
43
WSL665
6.5
6.7
44
WSL670
7
6.3
44
WSL675
7.5
5.8
44
WSL680
8
5.5
44
WSL690
9
5
45
WSL612
Y
12
5
60
WSL613
Y
13
4.6
60
WSL614
Y
14
4.3
60
WSL615
Y
15
4
60
WSL616
Y
16
3.75
60
WSL618
Y
18
3.3
60
WSL620
Y
20
3
60
WSL622
22
2.7
60
WSL624
24
2.5
60
WSL626
26
2.3
60
WSL628
28
2.15
60
WSL630
30
2
60
WSL632
32
1.85
60
WSL636
36
1.65
60
WSL640
40
1.5
60
WSL644
44
1.35
60
WSL648
48
1.25
60
*Add a suffix, “M” for Medical or leave it blank for non-medical.
www.AstrodyneTDI.com
PH: 908-353-5700 | FAX: 908-353-1021
• Universal Input Voltage: 90-264Vac 47-63Hz Class I or II
• Output Voltage Tolerance: +/-2.5% Typical, +/-5% Max, from
Full Load to No Load.
• Operating Temperature: 0 - 40°C
• Maximum Output Ripple:
• 5 - 6V: 50mVp-p
• 6.1 - 24V: 100mVp-p
• 24.1 - 36V: 150mVp-p
• 36.1 - 48V 200mVp-p
• Designed for Continuous Duty
• Hold-Up Time : 20mS Minimum @ 120 Vin
• Short Circuit and Over Load Protection
• SELV Output
• MTBF Calculated > 100,000 Hours @ 40°C
• 2 Hour Minimum Loaded Burn-in at 40°C Ambient for
standard output cord configurations
• Leakage current compliant to IEC60601-1 Category B and BF
• 5 Year Warranty
Available Features
• Precision Output Voltage setting
• Expanded Operating Temperatures
• Power On/Off Switch
• 400 Hz Input Rating
• DC Input Rating
• Additional Noise and/or Surge Protection
• LED Power On Indicator
• Fixed-in-place Input Cord
• Wall plug-in configuration
• Output Cord Sets and Connector Configurations
• Case Colors, Markings & Logos
• 16 Hour Burn-in
All specifications are typical at nominal input, full load, and 25°C unless
otherwise noted
© Copyright 2015, Astrodyne, Inc
This document is believed to be correct at time of publication and Astrodyne, Inc
accepts no responsibility for consequences from printing errors or inaccuracies.
Specifications are subject to change without notice
WSL 600 SERIES, 60 WATTS
HIGH EFFICIENCY, COMPACT DESIGN SWITCHMODE TECHNOLOGY
4.75
L CASE ENCLOSURE
3.00
3.00
ALSO AVAILABLE WITH INTERNATIONAL
PLUG-IN CONFIGURATION
1.89
1.89
4.75
A. WALL PLUG-IN OPTION
B. INPUT CORD OPTION
3.00
VARIOUS INPUT AND OUTPUT CORD
OPTIONS AVAILABLE
1.89
4.75
C. IEC 320 OPTION
Regulatory Compliance
IEC 320 OPTION
USED FOR MOST
INTERNATIONAL APPLICATIONS
Designed for use with medical, information technology, and general purpose equipment to the following standards: All models are
approved to:
• UL 60601-1 / 60950-1
• CSA 22.2 601-1 / 60950-1
• TUV EN 60601-1 / 60950-1
• CE LVD directive
• *cUL Mark
EMC: All models meet European EMC directive and FCC requirements.
Meets all EMC requirements from EN60601-1-2.
Emissions: Level B requirements of FCC CFR 47 part 15 and CISPR11
(EN55011) and CISPR22 (EN55022), EN61000-6-3 (light industrial)
and line harmonic emissions EN61000-3-2.
Immunity: CISPR24 (EN55024), EN61326 and EN61000-3-2.
Certification records are available upon project request.
www.AstrodyneTDI.com
PH: 908-353-5700 | FAX: 908-353-1021
4.75
3.00
TOP SURFACE MARKING
AREA = 4.41 X 2.09
© Copyright 2015, Astrodyne, Inc
This document is believed to be correct at time of publication and Astrodyne, Inc
accepts no responsibility for consequences from printing errors or inaccuracies.
Specifications are subject to change without notice