RSP1500 1500W S i n g l e Out put P ow er S uppl y series Universal AC input Protections:Short circuit/Over load/Over voltage/Over temperature Built-in active PFC function, PF>0.95 Forced air cooling by built-in DC ball bearing fan Built-in remote sense function Built-in remote ON-OFF control ZVS new technology AC input active surge current limiting High efficiency up to 91% Output voltage can be trimmed between 70~100% of the rated output voltage High power density 8.3W/cubic inch Current sharing up to 6000W (3+1) Alarm signal ouput Built-in 12 Volt/0.1 Amp auxiliary output for remote control Model Number Output Volts Output Amps OVP Min Load DC Volt Adjust Efficiency 5 Volts(DC) 12 Volts(DC) 15 Volts(DC) 24 Volts(DC) 27 Volts(DC) 48 Volts(DC) 240 Amps 125 Amps 100 Amps 63 Amps 56 Amps 32 Amps 0~240Amps 0~125Amps 0~100Amps 0~63Amps 0~56Amps 0~32Amps 4.5~5.5Volt(DC) 10~13.5Volt(DC) 13.5~16.5Volt(DC) 20~26.4Volt(DC) 24~30Volt(DC) 43~56Volt(DC) 80% 87% 87% 90% 90% 91% SINGLE OUTPUT RSP1500-5 RSP1500-12 RSP1500-15 RSP1500-24 RSP1500-27 RSP1500-48 WWW.ASTRODYNETDI.COM 5.75 ~ 6.75Volt(DC) 13.8 ~ 16.8Volt(DC) 17 ~ 20.5Volt(DC) 27.6 ~ 32.4Volt(DC) 31 ~ 36.5Volt(DC) 57.6~ 67.2Volt(DC) ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 RSP1500 1500W S i n g l e Out put P ow er S uppl y INPUT SPECIFICATIONS ENVIRONMENTAL SPECIFICATIONS Input Voltage Range (Note 3) Frequency Range Inrush Current, typ: (cold start) Input Current Leakage current Min Load Power Factor @ FL Oper. Temperature Storage Temperature Relative Humidity Temperature Coefficient MTBF Vibration 90 ~ 264VAC 127~370 Volts(DC) 47-63 Hz 30Amps/115V/60Amps 230V 17 Amps/115V; 8.0 Amps/ 230V < 2.0 mAmps / 240VAC See Selection Chart > 0.95 / 230VAC; 0.98 / 115VAC OUTPUT SPECIFICATIONS Voltage and Current Line Regulation Load Regulation Voltage Tolerance (Note 2) Ripple/Noise (Note 1) Hold Up Time @ FL Setup, Rise Time @ FL Over Voltage Protection Over Current Protection Over Temperature Protection DC Volt Adjust See Selection Chart ±0.5% ±2.0%: 5Volts(DC) ±0.5%: 12~48Volts(DC) ±2.0%: 5Volts(DC) ±1%: 12~48Volts(DC) 150mVpk-pk: 5~27Volts(DC) 200mVpk-pk: 48Volts(DC) 10mS: 5~12Volts(DC) 14mS: 15~24Volts(DC) 16mS: 27~48Volts(DC) 1500mS, 100mS See Selection Chart Shutdown o/p volage, re-power 105~135% rated output power Constant current limit,auto recover 95°C ±5 (TSW2 ) detected on heatsink of power transistor Shutdown o/p voltage, auto-recover See Selection Chart PHYSICAL SPECIFICATIONS Size Weight 278 x127 x 83.5mm (10.95”x5 ”x3.29”) 91.71 oz (2600g) series -20°C to +70°C (See Derate Curve) -40°C to +85°C, 10~95% RH 20~90% RH non cond ±0.05% / °C (0-50°C) 62.6KHrs min,MIL-HDBK-217F(25°C) 10~500Hz, 2G10min./1cycle, period for 60min. each along X, Y, Z axes GENERAL SPECIFICATIONS Safety Insulation Resistance EMI Harmonic Current Efficiency Isolation EMS Auxiliary power(Aux) Remote ON/OFF control Alarm signal output Output Voltage Trim Current Sharing UL60950-1, TUV EN60950-1 ≥ 100MΩ / 500Volts(DC) Compliance to EN55022 (CISPR22) Compliance to EN61000-3-2,-3 See Selection Chart 3000VAC Input - Output 1500VAC Input - Ground 500VAC Output - Ground Compliance to EN61000-4-2,3,4,5,6,8,11 ENV50204, EN55024 light Industry Level, Criteria A 12Volts @ 0.1Amps (only for remote ON/OFF control) Please see the Function Manual Please see the Function Manual Please see the Function Manual Please see the Function Manual NOTE 1. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 2. Tolerance : includes set up tolerance, line regulation and load regulation. 3. Derating may be needed under low input voltages. Please check the derating curve for more details. All specifications are typical at nominal input, full load, and 25°C unless otherwise noted WWW.ASTRODYNETDI.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 RSP-1500 series RSP1500 1500W Single Output Power Supply 1500W S i n g l e Out put P ow er S uppl y Mechanical Specification Case No.943A 240 series Unit:mm 11.2 16 max. 38 8-M4 L=5(Both Sides) 278 11.2 240 OUTPUT +V 4-M4 L=5 -V CN1 CN2 CN3 8 6 42 8 6 42 6 4 2 7 5 31 7 5 31 5 3 1 Air flow direction I/P LED SVR 1 2 3 AC Input Terminal Pin No. Assignment Pin No. 1 2 3 Control Pin No. Assignment(CN1,CN2) : HRS DF11-8DP-2DS or equivalent Assignment FG AC/N AC/L Pin No. 1 2 3,5,7 Assignment RCG RC2 -S Pin No. 4 6 8 RCG: Remote ON/OFF Ground RC2: Remote ON/OFF -S : -Remote Sensing Assignment Mating Housing Terminal TRIM HRS DF11-8DS HRS DF11-**SC LS(Current Share) or equivalent or equivalent +S TRIM: Adjustment of Output Voltage LS: Load Share +S: +Remote Sensing Control Pin No. Assignment(CN3) : HRS DF11-6DP-2DS or equivalent Pin No. 1 2 3 Assignment P OK GND P OK RCG Pin No. 4 5 6 P OK GND: Power OK Ground P OK: Power OK Signal RCG: Remote ON/OFF Ground Assignment Mating Housing Terminal AUXG HRS DF11-6DS HRS DF11-**SC RC1 or equivalent or equivalent AUX AUXG: Auxiliary Ground RC1: Remote ON/OFF AUX: Auxiliary Output PFC fosc : 70KHz PWM fosc : 100KHz Block Diagram +S I/P EMI FILT ER ACTIVE INRUSH CURRENT LIMITING RECTIFIERS & PFC RECTIFIERS & FILTER POWER SWITCHING +V -V -S PFC CONTROL O.T.P. O.V.P. O.L.P. PWM CONTROL LOAD SHARING AUX POWER WWW.ASTRODYNETDI.COM DETECTION CIRCUIT P OK REMOTE CONTROL RC LS FAN RECTIFIERS & FILTER AUX POWER (12V/0.1A) ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 File Name:RSP-1500-SPEC 2013-11-01 R S P - 1 5 0 0 series R S P 1 5 0 0 series 1500W Single Output Power Supply 1500W S i n g l e Out put P ow er S uppl y Derating Curve Static Characteristics 100 Others +12V,+15V 80 100 90 60 50 +5V 40 80 70 20 -20 60 0 10 20 30 40 45 50 60 70 (HORIZONTAL) 90 AMBIENT TEMPERATURE (℃) 100 120 140 150 160 180 200 220 240 264 INPUT VOLTAGE (V) 60Hz Function Manual 1.Remote ON/OFF (1)Remote ON/OFF control becomes available by applying voltage in CN1 & CN2 & CN3 (2)Table 1.1 shows the specification of Remote ON/OFF function (3)Fig.1.2 shows the example to connect Remote ON/OFF control function Table 1.1 Specification of Remote ON/OFF Connection Method Fig. 1.2(A) Output on SW Open SW Logic Output off SW Close Fig. 1.2(B) SW Open SW Close Fig. 1.2(C) SW Close SW Open Fig.1.2 Examples of connecting remote ON/OFF (A)Using external voltage source (B)Using internal 12V auxiliary output AUX 2.2KΩ 12V typ. 150Ω AUX 2.2KΩ RC1 5V RC2 12V typ. 620Ω RCG AUXG SW 150Ω RC1 RC2 RCG SW AUXG (C)Using internal 12V auxiliary output AUX 2.2KΩ 12V typ. 150Ω RC1 RC2 SW RCG WWW.ASTRODYNETDI.COM AUXG ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 File Name:RSP-1500-SPEC 2013-11-01 RSP-1500 1500W Single Output Power Supply series RSP1500 1500W S i n g l e Out put P ow er S uppl y 2.Alarm Signal Output (1)Alarm signal is sent out through "P OK" & "P OK GND" pins (2)An external voltage source is required for this function. The maximum applied voltage is 50V and the maximum sink current is 10mA (3)Table 2.1 explain the alarm function built-in the power supply Function Description Output of alarm(P OK) The signal is "Low" when the power supply is above Low 65% of the rated output voltage-Power OK (0.5V max at 10mA) P OK High or open The signal turns to be "High" when the power supply (External applied voltage is under 65% of the rated output voltage-Power Fail 10mA max.) series P OK R 0.1uF 100KΩ V External voltage and R (The max. Sink is 10mA and 50V) P OK GND Fig. 2.2 Internal circuit of P OK (Open collector method) Table 2.1 Explanation of alarm 3.Output Voltage TRIM (1)Adjustment of output voltage is possible between 70~100%(Typ.) of the rated output which is shown in Fig. 3.1 (2)Connecting a resistor externally between TRIM and-S on CN1 or CN2 that is shown in Fig. 3.2. (3)+S & +V, -S & -V also need to be connected on CN1 or CN2. Vout +S 100% +V LOAD -V 90% -S 80% TRIM 70% R(0.5W) -S R 0Ω 470Ω 1.8KΩ OPEN Fig. 3.1 External Resistor (Typical) 4.Current Sharing (1)Parallel operation is available by connecting the units shown as below (+S,-S and LS are connected mutually in parallel): (2)The voltage difference among each output should be minimized that less than 0.2V is required (3)The total output current must not exceed the value determined by the following equation (Output current at parallel operation)=(The rated current per unit)×(Number of unit)×0.9 (4) In parallel operation 4 units is the maximum, please consult the manufacture for other applications (5) When remote sensing is used in parallel operation, the sensing wire must be connected only to the master unit Fig. 3.2 Output voltage trimming No.1(Master) +S -S CN1 LS +S -S CN2 LS V+ V- AC/L AC/N No.2(Slave) +S -S CN1 LS +S -S CN2 LS V+ V- AC/L AC/N +S No.3(Slave) +S -S CN1 LS +S -S CN2 LS V+ -S +V -V Load V- AC/L AC/N No.4(Slave) +S -S CN1 LS +S -S CN2 LS V+ V- AC/L AC/N WWW.ASTRODYNETDI.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 File Name:RSP-1500-SPEC 2013-11-01