RSP1500 series - Power Supplies

RSP1500
1500W S i n g l e Out put P ow er S uppl y
series
Universal AC input
Protections:Short circuit/Over load/Over voltage/Over
temperature
Built-in active PFC function, PF>0.95
Forced air cooling by built-in DC ball bearing fan
Built-in remote sense function
Built-in remote ON-OFF control
ZVS new technology
AC input active surge current limiting
High efficiency up to 91%
Output voltage can be trimmed between 70~100% of the
rated output voltage
High power density 8.3W/cubic inch
Current sharing up to 6000W (3+1)
Alarm signal ouput
Built-in 12 Volt/0.1 Amp auxiliary output for remote control
Model Number
Output Volts
Output Amps OVP
Min Load
DC Volt Adjust
Efficiency
5 Volts(DC)
12 Volts(DC)
15 Volts(DC)
24 Volts(DC)
27 Volts(DC)
48 Volts(DC)
240 Amps
125 Amps
100 Amps
63 Amps
56 Amps
32 Amps
0~240Amps
0~125Amps
0~100Amps
0~63Amps
0~56Amps
0~32Amps
4.5~5.5Volt(DC)
10~13.5Volt(DC)
13.5~16.5Volt(DC)
20~26.4Volt(DC)
24~30Volt(DC)
43~56Volt(DC)
80%
87%
87%
90%
90%
91%
SINGLE OUTPUT
RSP1500-5
RSP1500-12
RSP1500-15
RSP1500-24
RSP1500-27
RSP1500-48
WWW.ASTRODYNETDI.COM
5.75 ~ 6.75Volt(DC)
13.8 ~ 16.8Volt(DC)
17 ~ 20.5Volt(DC)
27.6 ~ 32.4Volt(DC)
31 ~ 36.5Volt(DC)
57.6~ 67.2Volt(DC)
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
RSP1500
1500W S i n g l e Out put P ow er S uppl y
INPUT SPECIFICATIONS
ENVIRONMENTAL SPECIFICATIONS
Input Voltage Range (Note 3)
Frequency Range
Inrush Current, typ: (cold start)
Input Current
Leakage current
Min Load
Power Factor @ FL
Oper. Temperature Storage Temperature Relative Humidity
Temperature Coefficient MTBF
Vibration
90 ~ 264VAC 127~370 Volts(DC)
47-63 Hz
30Amps/115V/60Amps 230V
17 Amps/115V; 8.0 Amps/ 230V
< 2.0 mAmps / 240VAC
See Selection Chart
> 0.95 / 230VAC; 0.98 / 115VAC
OUTPUT SPECIFICATIONS
Voltage and Current Line Regulation
Load Regulation
Voltage Tolerance (Note 2)
Ripple/Noise (Note 1)
Hold Up Time @ FL
Setup, Rise Time @ FL
Over Voltage Protection
Over Current Protection
Over Temperature Protection
DC Volt Adjust
See Selection Chart
±0.5%
±2.0%: 5Volts(DC)
±0.5%: 12~48Volts(DC)
±2.0%: 5Volts(DC)
±1%: 12~48Volts(DC)
150mVpk-pk: 5~27Volts(DC)
200mVpk-pk: 48Volts(DC)
10mS: 5~12Volts(DC)
14mS: 15~24Volts(DC)
16mS: 27~48Volts(DC)
1500mS, 100mS
See Selection Chart
Shutdown o/p volage, re-power
105~135% rated output power
Constant current limit,auto recover
95°C ±5 (TSW2 ) detected on heatsink of power transistor Shutdown o/p voltage, auto-recover
See Selection Chart
PHYSICAL SPECIFICATIONS
Size
Weight
278 x127 x 83.5mm (10.95”x5 ”x3.29”)
91.71 oz (2600g)
series
-20°C to +70°C (See Derate Curve)
-40°C to +85°C, 10~95% RH
20~90% RH non cond
±0.05% / °C (0-50°C)
62.6KHrs min,MIL-HDBK-217F(25°C)
10~500Hz, 2G10min./1cycle, period for
60min. each along X, Y, Z axes
GENERAL SPECIFICATIONS
Safety
Insulation Resistance
EMI
Harmonic Current
Efficiency
Isolation
EMS
Auxiliary power(Aux)
Remote ON/OFF control
Alarm signal output
Output Voltage Trim
Current Sharing
UL60950-1, TUV EN60950-1
≥ 100MΩ / 500Volts(DC)
Compliance to EN55022 (CISPR22)
Compliance to EN61000-3-2,-3
See Selection Chart
3000VAC Input - Output
1500VAC Input - Ground
500VAC Output - Ground
Compliance to EN61000-4-2,3,4,5,6,8,11
ENV50204, EN55024
light Industry Level, Criteria A
12Volts @ 0.1Amps (only for remote
ON/OFF control)
Please see the Function Manual
Please see the Function Manual
Please see the Function Manual
Please see the Function Manual
NOTE
1. Ripple & noise are measured at 20MHz of bandwidth by using a 12”
twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
2. Tolerance : includes set up tolerance, line regulation and load regulation.
3. Derating may be needed under low input voltages. Please check the
derating curve for more details.
All specifications are typical at nominal input, full load, and 25°C unless otherwise noted
WWW.ASTRODYNETDI.COM
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
RSP-1500
series
RSP1500
1500W Single Output Power Supply
1500W S i n g l e Out put P ow er S uppl y
Mechanical Specification
Case No.943A
240
series
Unit:mm
11.2
16 max.
38
8-M4 L=5(Both Sides)
278
11.2
240
OUTPUT
+V
4-M4 L=5
-V
CN1 CN2 CN3
8 6 42 8 6 42 6 4 2
7 5 31 7 5 31 5 3 1
Air flow
direction
I/P
LED
SVR
1
2
3
AC Input Terminal Pin No. Assignment
Pin No.
1
2
3
Control Pin No. Assignment(CN1,CN2) : HRS DF11-8DP-2DS or equivalent
Assignment
FG
AC/N
AC/L
Pin No.
1
2
3,5,7
Assignment
RCG
RC2
-S
Pin No.
4
6
8
RCG: Remote ON/OFF Ground
RC2: Remote ON/OFF
-S : -Remote Sensing
Assignment Mating Housing
Terminal
TRIM
HRS DF11-8DS HRS DF11-**SC
LS(Current Share) or equivalent or equivalent
+S
TRIM: Adjustment of Output Voltage
LS: Load Share
+S: +Remote Sensing
Control Pin No. Assignment(CN3) : HRS DF11-6DP-2DS or equivalent
Pin No.
1
2
3
Assignment
P OK GND
P OK
RCG
Pin No.
4
5
6
P OK GND: Power OK Ground
P OK: Power OK Signal
RCG: Remote ON/OFF Ground
Assignment Mating Housing
Terminal
AUXG
HRS DF11-6DS HRS DF11-**SC
RC1
or equivalent or equivalent
AUX
AUXG: Auxiliary Ground
RC1: Remote ON/OFF
AUX: Auxiliary Output
PFC fosc : 70KHz
PWM fosc : 100KHz
Block Diagram
+S
I/P
EMI
FILT ER
ACTIVE
INRUSH
CURRENT
LIMITING
RECTIFIERS
&
PFC
RECTIFIERS
&
FILTER
POWER
SWITCHING
+V
-V
-S
PFC
CONTROL
O.T.P.
O.V.P.
O.L.P.
PWM
CONTROL
LOAD
SHARING
AUX
POWER
WWW.ASTRODYNETDI.COM
DETECTION
CIRCUIT
P OK
REMOTE
CONTROL
RC
LS
FAN
RECTIFIERS
&
FILTER
AUX POWER
(12V/0.1A)
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
File Name:RSP-1500-SPEC 2013-11-01
R S P - 1 5 0 0 series
R S P 1 5 0 0 series
1500W Single Output Power Supply
1500W S i n g l e Out put P ow er S uppl y
Derating Curve
Static Characteristics
100
Others
+12V,+15V
80
100
90
60
50
+5V
40
80
70
20
-20
60
0
10
20
30
40 45 50
60
70 (HORIZONTAL)
90
AMBIENT TEMPERATURE (℃)
100
120
140
150
160
180
200
220
240
264
INPUT VOLTAGE (V) 60Hz
Function Manual
1.Remote ON/OFF
(1)Remote ON/OFF control becomes available by applying voltage in CN1 & CN2 & CN3
(2)Table 1.1 shows the specification of Remote ON/OFF function
(3)Fig.1.2 shows the example to connect Remote ON/OFF control function
Table 1.1 Specification of Remote ON/OFF
Connection Method
Fig. 1.2(A)
Output on
SW Open
SW Logic
Output off
SW Close
Fig. 1.2(B)
SW Open
SW Close
Fig. 1.2(C)
SW Close
SW Open
Fig.1.2 Examples of connecting remote ON/OFF
(A)Using external voltage source
(B)Using internal 12V auxiliary output
AUX
2.2KΩ
12V typ.
150Ω
AUX
2.2KΩ
RC1
5V
RC2
12V typ.
620Ω
RCG
AUXG
SW
150Ω
RC1
RC2
RCG
SW
AUXG
(C)Using internal 12V auxiliary output
AUX
2.2KΩ
12V typ.
150Ω
RC1
RC2
SW
RCG
WWW.ASTRODYNETDI.COM
AUXG
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
File Name:RSP-1500-SPEC 2013-11-01
RSP-1500
1500W Single Output Power Supply
series
RSP1500
1500W S i n g l e Out put P ow er S uppl y
2.Alarm Signal Output
(1)Alarm signal is sent out through "P OK" & "P OK GND" pins
(2)An external voltage source is required for this function. The maximum applied voltage
is 50V and the maximum sink current is 10mA
(3)Table 2.1 explain the alarm function built-in the power supply
Function
Description
Output of alarm(P OK)
The signal is "Low" when the power supply is above Low
65% of the rated output voltage-Power OK
(0.5V max at 10mA)
P OK
High or open
The signal turns to be "High" when the power supply
(External applied voltage
is under 65% of the rated output voltage-Power Fail
10mA max.)
series
P OK
R
0.1uF
100KΩ
V
External voltage and R
(The max. Sink is 10mA and 50V)
P OK GND
Fig. 2.2 Internal circuit of P OK (Open collector method)
Table 2.1 Explanation of alarm
3.Output Voltage TRIM
(1)Adjustment of output voltage is possible between 70~100%(Typ.) of the rated output which is shown in Fig. 3.1
(2)Connecting a resistor externally between TRIM and-S on CN1 or CN2 that is shown in Fig. 3.2.
(3)+S & +V, -S & -V also need to be connected on CN1 or CN2.
Vout
+S
100%
+V
LOAD
-V
90%
-S
80%
TRIM
70%
R(0.5W)
-S
R
0Ω
470Ω 1.8KΩ OPEN
Fig. 3.1 External Resistor (Typical)
4.Current Sharing
(1)Parallel operation is available by connecting the units shown as below
(+S,-S and LS are connected mutually in parallel):
(2)The voltage difference among each output should be minimized that less than 0.2V is required
(3)The total output current must not exceed the value determined by the following equation
(Output current at parallel operation)=(The rated current per unit)×(Number of unit)×0.9
(4) In parallel operation 4 units is the maximum, please consult the manufacture for other
applications
(5) When remote sensing is used in parallel operation, the sensing wire must be connected only
to the master unit
Fig. 3.2 Output voltage trimming
No.1(Master)
+S
-S CN1
LS
+S
-S CN2
LS
V+
V-
AC/L AC/N
No.2(Slave)
+S
-S CN1
LS
+S
-S CN2
LS
V+
V-
AC/L AC/N
+S
No.3(Slave)
+S
-S CN1
LS
+S
-S CN2
LS
V+
-S
+V
-V
Load
V-
AC/L AC/N
No.4(Slave)
+S
-S CN1
LS
+S
-S CN2
LS
V+
V-
AC/L AC/N
WWW.ASTRODYNETDI.COM
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
File Name:RSP-1500-SPEC 2013-11-01