Inline The flexible I/O system for the control cabinet Inline – the flexible I/O system for the control cabinet The Inline I/O system from Phoenix Contact is characterized by its large number of I/O and function terminals as well as openness for all popular fieldbus systems and Ethernet networks. Numerous practical features round off the system. With Inline you have a proven I/O system which excels thanks to its reliability, easy handling, and above all its unrivalled flexibility. Find out more about the possible applications of the Inline system. 2 PHOENIX CONTACT Table of contents Inline functions Pages 4 - 5 Inline features Pages 6 - 7 Inline bus openness Pages 8 - 9 Inline field extensions Pages 10 - 11 Inline safety Pages 12 - 13 Inline Ex-i Pages 14 - 15 Inline configuration Pages 16 - 17 Inline examples of use Pages 18 - 19 Inline product overview Pages 20 - 21 PHOENIX CONTACT 3 Inline functions – respond flexibly to every requirement Inline is the versatile I/O system for the control cabinet. A wide range of I/O modules and function terminals are available for all popular fieldbus systems and Ethernet networks. You have the option to extend your system with virtually any function. This makes the Inline system from Phoenix Contact a flexible all-rounder, which you can use to combine your automation functions easily and individually. Discover the flexibility of the Inline system. 4 PHOENIX CONTACT Flexible thanks to the modular design The Inline system has a modular design: it can be extended with a range of input and output, communication, and function terminals. This makes it particularly flexible – always tailored to your requirements. Saves space in the control cabinet The highly modular 12.5 mm modules enable you to extend your station using a minimal amount of space. Safety applications or I/Os for potentially explosive areas can also be connected and integrated easily. Wide range of function terminals Inline enables the flexible and application-specific combination of digital and analog I/O channels including the most popular standard functions: Digital inputs Digital outputs Analog inputs Analog outputs Temperature recording Counters Pulse encoders Position detection Energy data acquisition Communication PHOENIX CONTACT 5 Inline features – discover advantages in every detail Discover the practical advantages of Inline: the bus and power supply do not have to be wired, they are connected automatically when the extension modules are plugged in. Diagnostic LEDs for network and local bus Bus coupler with integrated inputs and outputs COMBICON spring-cage technology ensures fast I/O wiring. Thanks to the wiring level which is separated from the electronics, module replacement can be carried out quickly and easily. Clearly numbered terminal points Color coding to easily distinguish between I/O functions Discover these and other advantages with Inline from Phoenix Contact. Network or bus connection Inline Block IO The space-saving extension of the modular Inline I/O system: the compact and flat Inline Block IO integrates a fixed number of I/Os in your network. Significant benefits can be achieved in terms of handling and costs for low numbers of I/Os in particular, as I/O modules and bus couplers are combined in a single device. 6 PHOENIX CONTACT Integrated shield connection directly on the terminal saves space in the control cabinet Status and diagnostic LEDs on every local bus terminal optimally indicate the operating state of the Inline station Wiring level separated from the electronics I/O modules can be connected with a high degree of modularity Individual marking Terminals, conductors, cables, and devices can be marked quickly and easily using the MARKING system. Flexible connection Whether single, two, three or four-wire technology, and whatever your preferred connection technology for connecting your sensors or actuators: the Inline system always offers the ideal solution. Color coding of the terminal points simplifies wiring Plug coding (optional) prevents the incorrect connection of plugs Selective segmentation Increased system safety thanks to independently protected and separately switched station segments. PHOENIX CONTACT 7 Inline bus openness – system-independent integration Thanks to its freely selectable bus coupler, the Inline system can be connected to all popular fieldbus systems and Ethernet networks. The communication terminals enable you to integrate an additional communication system in your Inline station as a subsystem. For central or distributed control tasks, you can simply replace the bus coupler with a compact Inline controller. All controllers are parameterized and programmed using the IEC 61131-based PC WORX software. Bus openness The Inline system is characterized by its high degree of integration in various fieldbus systems. All popular Ethernet-based networks are, of course, also supported. 8 PHOENIX CONTACT Scalable controllers Compact controllers for simple applications Programmable class 100 compact controllers can be optimally extended with the Inline function terminals. They offer high function density at a low price: ideal for simple applications, even in distributed automation. High-performance controllers for sophisticated applications PROFINET-compatible class 300 highperformance controllers are used to control average to sophisticated automation tasks. Two Ethernet ports with an integrated switch enable flexible connection to a higher-level control room, a local operating station or I/O modules. Integrate subsystems Communication master terminals can be used to integrate various subsystems under an Inline station, without having to use another bus coupler. Easy engineering PC WORX – the consistent IEC-compliant engineering software for all Phoenix Contact controllers PC WORX EXPRESS – the little brother to PC WORX is free and ideal for the easy programming of compact controllers PHOENIX CONTACT 9 Inline field extension – flexible local bus extensions The local bus in your Inline station is very flexible and is tailored to your requirements. When it comes to large distances, limited space in the control cabinet or different degrees of protection, you can always find the right solution among various local bus extensions. 10 PHOENIX CONTACT Local bus extension to the field Fieldline Modular devices with IP65/IP67 protection can be combined easily and flexibly with an Inline station via the Inline branch terminal – without any additional bus couplers. This saves time as less effort is required thanks to direct connection to the existing station. Easy data transmission over large distances Multiplex mode The Inline field multiplexer transmits data in the easiest way, even over large distances. Data transmission via: • 2-wire copper cable up to 12 km • Permanent phone line up to 20 km (with converter) • Fiber optics up to 45 km (with converter) UL ST CE RE LE Easy point-to-point communication Inline field multiplexers transmit industrial signals in pairs, point-to-point – whether via a two-wire copper cable, fiber optic cable, modem or wirelessly. A number of digital and analog Inline I/O terminals can be freely combined – without using any software. Up to 45 km US UM 1.1 2.1 1.1 2.1 1.1 2.1 1.2 2.2 1.2 2.2 1.2 2.2 1.3 2.3 1.3 2.3 1.3 2.3 1.4 2.4 1.4 2.4 1.4 2.4 UL ST CE RE LE US UM 1.1 2.1 1.1 2.1 1.1 2.1 1.2 2.2 1.2 2.2 1.2 2.2 1.3 2.3 1.3 2.3 1.3 2.3 1.4 2.4 1.4 2.4 1.4 2.4 Extension options of the Inline local bus Local bus extension Using a local bus extension terminal, you can extend your Inline station in the control cabinet by one or more rows. 1.2 2.2 1.3 2.3 1.4 2.4 Up to 20 m UL ST CE RE LE Communication via Bluetooth Benefit from the advantages of industrial Bluetooth technology for your I/O communication with Inline Block IO devices. Easy to install and providing reliable transmission, Bluetooth is the ideal solution for data transmission at input and output level. US UM 1.1 2.1 1.1 2.1 1.1 2.1 1.2 2.2 1.2 2.2 1.2 2.2 1.3 2.3 1.3 2.3 1.3 2.3 1.4 2.4 1.4 2.4 1.4 2.4 Local bus extension to the field Using the branch terminal, you can connect Fieldline devices with IP65/IP67 protection to the Inline local bus. 1.2 2.2 1.3 2.3 1.4 2.4 Max. 40 m Max. 16 devices PHOENIX CONTACT 11 Inline safety – safe I/Os with SafetyBridge technology Use our SafetyBridge I/Os to integrate functional safety in your Inline I/O level independently of the network. SafetyBridge technology performs all the safety-related functions in your machine or system. Regardless of which Inline bus coupler you use, the SafetyBridge I/O modules do not require an additional safety controller to operate and are approved for all popular Ethernet networks. Benefit from the flexibility and cost-saving advantages of SafetyBridge technology. What are the advantages of independence from the network? SafetyBridge technology can be integrated extremely easily into all popular fieldbus and Ethernet-based networks. Continue to benefit from the advantages of your preferred network solution. No additional safety networks are required, which saves you time and money during the design of your machines and systems. 12 PHOENIX CONTACT Various I/O modules • Maximum of 16 safe inputs • Maximum of 8 safe outputs • One relay module SafetyBridge technology: extremely easy Central or distributed installation You decide how you want to use the flexible I/O modules. No safety controller required The I/Os with integrated SafetyBridge technology handle the complete processing of safety functions. Your standard control system only handles data exchange between the I/O modules. Easy configuration using SAFECONF After completing the safety configuration, the generated safety logic is transferred to the safe logic module via the standard control system. Intelligent logic module • 8 safe outputs • Can be linked to up to 16 additional safe I/O modules SAFECONF software As you can see, functional safety is very easy to integrate in your machine or system. PHOENIX CONTACT 13 Inline Ex-i – intrinsically safe I/Os for the Ex area The intrinsically safe I/Os connect input and output signals to your network or bus system. A selection of standard I/O terminals is available for use in potentially explosive and non-potentially explosive areas up to zone 2. Additional input and output signals from potentially explosive areas of zones 1 and 0 can be connected to the blue I/O modules. To do this, simply mount the modules on the Inline station. Parameterize the terminals with FDT technology and use channel-specific diagnostics for troubleshooting. Ex-i analog input/output Thanks to two current ranges (0/4 to 20 mA) for input and output, as well as an input voltage range of 0 to 10 V, this 4-channel module can be used universally. Ex-i power supply The power supply indicates the current status via several control displays. The supply terminal can distinguish between the different states: voltage present, high load range, and overload. The terminal is electronically protected against overload and is very energy efficient. 14 PHOENIX CONTACT Ex-i temperature input Operation and installation of I/Os in Ex zones The 4-channel temperature input module supports standard thermocouple sensors and commercially available resistive temperature measuring devices. The shield connection integrated on the terminal enables easy wiring and provides protection against electromagnetic interference. Non-potentially explosive area ZONE 2 0.0 - 0.1% per year or max. 10 hours ZONE 1 and 21 0.1 - 10% per year or max. 10 - 1000 hours ZONE 0 and 20 > 10% per year or 1000 hours Ex-i digital input/output The 4-channel digital I/O module supports inputs for NAMUR initiators and mechanical contacts, outputs for intrinsically safe solenoid valves, acoustic alarm indicators, and signal lamps. PHOENIX CONTACT 15 Inline configuration – software-supported planning and configuration Plan and configure your I/O station quickly and easily using Project+ and CLIP PROJECT. The created station is based on your requirements. Technical data and specifications are compared and taken into consideration. The end result is an efficient, error-free station structure. We offer a complete package: support for planning, configuration, startup parameterization, and integration in the application programming, e.g., STEP 7 (TIA portal) from Siemens. Use these tools to engineer your entire control cabinet! Efficient configuration Transfer your Inline station planned using Project+ to CLIP PROJECT and conveniently complete the configuration of your entire DIN rail. Optimum interaction with CAE systems results in a consistent and efficient process chain. Create the marking for your Inline station quickly and easily with CLIP PROJECT Marking. 16 PHOENIX CONTACT Conveniently integrate the signals of the Inline station in your controller. Corresponding device descriptions are available to download for all relevant communication systems. In addition to standard I/O modules, the Inline system also offers flexible special function modules. These modules can be parameterized in various ways. Use specially tailored function block libraries for fast startup and error-free parameterization of your I/O components. FDT technology allows Inline modules to be parameterized independently of the controller. Special device DTMs offer tailor-made parameterization windows. Easy station planning Carry out configuration quickly and easily with Project+. With no training required in the use of configuration rules, create the right I/O stations for your application effectively. By comparing all specifications, the software ensures that the modules are optimally coordinated. Errors such as choosing the wrong module are eliminated. Project+ can be downloaded free of charge from our website. PHOENIX CONTACT 17 Inline examples of use – ideal for a wide range of industry solutions Are you at home in the automotive industry, do you specialize in machine building, planning water and wastewater treatment plants or automating logistics centers? Whatever the industry for your automation solution, the Inline system provides the right terminals for your specific area of application. It is flexible and future-oriented, meaning investment costs are also secured even if subsequent adaptations are required. Intelligent communication You can perform automation tasks efficiently in warehouse logistics and conveying technology using the various communication terminals, such as the universal, serial communication terminal or the IO-Link master for the Inline system. Optimum acquisition Specific measured values can be optimally acquired in water and wastewater treatment applications using the power measurement terminal from the Inline system. 18 PHOENIX CONTACT Reliability is of paramount importance to us The Inline system has many industryspecific and country-specific approvals. With these approvals, you can be sure that the requirements of your specific industry are met. New approvals are constantly being added to our Inline product range. Safe networking A high level of system safety is one of the most important requirements in the automotive industry. With the safe input and output terminals from the Inline system, safety requirements up to PL e (EN ISO 13849-1), SIL 3 (IEC 61508), and SIL CL 3 (EN IEC 62061) are met. Cost-effective automation The Inline ME versions are particularly suitable for space-saving and inexpensive use in applications in the series production of machines. PHOENIX CONTACT 19 Product overview Ethernet Order No. 2703994 Order No. 2878379 IL PN BK DI8 DO4 2TX-PAC IL PN BK DI8 DO4 2SCRJPAC • PROFINET I/O device functionality (stack 2.2) • 8 inputs, 24 V DC • 4 outputs, 500 mA • 0.8 A at UL • RJ45 connection • 80 mm design width Order No. 2897758 Order No. 2878146 ILB PN 24 DI16 DIO16-2TX • PROFINET I/O device functionality (stack 3.1) • 8 inputs, 24 V DC • 4 outputs, 500 mA • 0.8 A at UL • SCRJ45 connection • 80 mm design width • 16 inputs, 24 V DC • 16 inputs/outputs, 24 V DC, 500 mA (can be freely selected) • 2 and 3-wire connection • Integrated 3-port switch • RJ45 connection • 156 mm design width Modbus TCP (UDP) Modbus TCP Order No. 2703981 Order No. 2832962 IL EIP BK DI8 DO4 2TX-PAC IL ETH BK DI8 DO4 2TX-PAC ILB ETH 24 DI16 DIO16-2TX • • • • • • • EtherNet/IP™, Version 1.2 HTTP, BootP 8 inputs, 24 V DC 4 outputs, 500 mA 0.8 A at UL RJ45 connection 80 mm design width • • • • • • • Modbus TCP (UDP) HTTP, TFTP, BootP, SNMP 8 inputs, 24 V DC 4 outputs, 500 mA 0.8 A at UL RJ45 connection 80 mm design width • 16 inputs, 24 V DC • 16 inputs/outputs, 24 V DC, 500 mA (can be freely selected) • 2 and 3-wire connection • Integrated 3-port switch • RJ45 connection • 156 mm design width Order No. 2692380 Order No. 2897570 Order No. 2700174 Order No. 2692076 IL S3 BK DI8 DO4 2TX-PAC ILB S3 24 DI16 DIO 16-2TX ILB S3 24 DI8 DO4 AO2 INC-IN2 ILB S3 AI4 AO2-2TX • • • • • • • 16 inputs, 24 V DC • 16 inputs/outputs, 24 V DC, 500 mA (can be freely selected) • 2 and 3-wire connection • Integrated 3-port switch • RJ45 connection • 156 mm design width • • • • • • • • • 4 inputs, 0 - 5 V, ±5 V, 0 - 10 V, ±10 V, 0 - 20 mA, ±20 mA, 4 - 20 mA, Pt100, Pt500, Pt1000, etc. • 2 outputs, 0 - 5 V, ±5 V, 0 - 10 V, ±10 V, 0 - 20 mA, ±20 mA, 4 - 20 mA • 16 bits • 156 mm design width sercos specification V1.1.2 8 inputs, 24 V DC 4 outputs, 500 mA 0.8 A at UL RJ45 connection 80 mm design width 20 PHOENIX CONTACT Positioning controller for 2 axes 2 analog outputs, ±10 V 2 inputs for incremental encoder 8 digital inputs, 24 V DC 4 digital outputs, 24 V DC, 500 mA 2 and 3-wire connection RJ45 connection 156 mm design width Fieldbuses Order No. 2861580 Order No. 2862165 Order No. 2861506 IBS IL 24 BK-T/U-PAC IBS IL 24 BK-LK/45-PAC IBS IL 24 BK RB-LK-PAC • • • • • • • • • • • • • • INTERBUS Incl. branch bus terminal support 2 A at UL Bus connection via Inline plug 48.8 mm design width INTERBUS 2 A at UL Fiber optic connection, 45° outlet 85 mm design width INTERBUS With INTERBUS remote bus branch 2 A at UL Fiber optic connection 85 mm design width Order No. 2862330 Order No. 2862343 Order No. 2862356 Order No. 2862369 ILB IB 24 DI16 ILB IB 24 DI32 ILB IB 24 DO16 ILB IB 24 DO32 • • • • • • • • • • • • • • • • 16 inputs, 24 V DC 2 and 3-wire connection Bus connection via Inline plug 95 mm design width 32 inputs, 24 V DC 2 and 3-wire connection Bus connection via Inline plug 156 mm design width 16 outputs, 24 V DC, 500 mA 2 and 3-wire connection Bus connection via Inline plug 95 mm design width Order No. 2862372 Order No. 2862385 Order No. 2878777 ILB IB 24 DI8 DO8 ILB IB 24 DI16 DO16 ILB IB AI4 AO2 • • • • • • • • • • • 4 inputs, 0 - 5 V, ±5 V, 0 - 10 V, ±10 V, 0 - 20 mA, ±20 mA, 4 - 20 mA, Pt100, Pt500, Pt1000, etc. • 2 outputs, 0 - 5 V, ±5 V, 0 - 10 V, ±10 V, 0 - 20 mA, ±20 mA, 4 - 20 mA • 16 bits • 156 mm design width 8 inputs, 24 V DC 8 outputs, 24 V DC, 500 mA 2 and 3-wire connection Bus connection via Inline plug 95 mm design width 16 inputs, 24 V DC 16 outputs, 24 V DC, 500 mA 2 and 3-wire connection Bus connection via Inline plug 156 mm design width 32 outputs, 24 V DC, 500 mA 2 and 3-wire connection Bus connection via Inline plug 156 mm design width PHOENIX CONTACT 21 Fieldbuses Order No. 2692322 Order No. 2862246 Order No. 2862398 Order No. 2862408 IL PB BK DI8 DO4/EF-PAC IL PB BK DP/V1-PAC ILB PB 24 DI32 ILB PB 24 DO32 • • • • • • • • • • • • • • • • • • • • PROFIBUS DP and DP/V1 PROFIsafe-compatible IO-Link calls 8 inputs, 24 V DC 4 outputs, 500 mA 0.8 A at UL D-SUB connection 80 mm design width PROFIBUS DP and DP/V1 2 A at UL D-SUB connection 85 mm design width 32 inputs, 24 V DC 2 and 3-wire connection D-SUB connection 156 mm design width Order No. 2862411 Order No. 2863562 Order No. 2878874 ILB PB 24 DI16 DO16 ILB PB 24 DI8 DIO8 ILB PB AI4 AO2 • • • • • • 8 inputs, 24 V DC • 8 inputs/outputs, 24 V DC, 500 mA (can be freely selected) • 2 and 3-wire connection • D-SUB connection • 95 mm design width • 4 inputs, 0 - 5 V, ±5 V, 0 - 10 V, ±10 V, 0 - 20 mA, ±20 mA, 4 - 20 mA, Pt100, Pt500, Pt1000, etc. • 2 outputs, 0 - 5 V, ±5 V, 0 - 10 V, ±10 V, 0 - 20 mA, ±20 mA, 4 - 20 mA • 16 bits • 156 mm design width 16 inputs, 24 V DC 16 outputs, 24 V DC, 500 mA 2 and 3-wire connection D-SUB connection 156 mm design width Modbus RTU Order No. 2897211 Order No. 2862602 Order No. 2878696 IL DN BK DI8 DO4-PAC ILB DN 24 DI16 DO16 IL MOD BK DI8 DO4-PAC • • • • • • • • • • • • • • • • • DeviceNetTM 8 inputs, 24 V DC 4 outputs, 500 mA 0.8 A at UL TWIN-COMBICON connection Incl. CLIPFIX 35 end bracket 80 mm design width 22 PHOENIX CONTACT 16 inputs, 24 V DC 16 outputs, 24 V DC, 500 mA 2 and 3-wire connection Bus connection via TWIN-COMBICON plug • 156 mm design width Modbus RTU (ASCII) 8 inputs, 24 V DC 4 outputs, 500 mA 0.8 A at UL D-SUB connection 80 mm design width 32 inputs, 24 V DC, 500 mA 2 and 3-wire connection D-SUB connection 156 mm design width Fieldbuses Order No. 2718701 Order No. 2862592 Order No. 2861205 IL CAN BK-TC-PAC ILB CO 24 DI16 DO16 IB IL 24 MUX MA-PAC • • • • • • • • • • • Point-to-point transmission of max. 512 I/O data via 2-wire cables up to max. 12 km • Max. 512 digital or 32 analog I/Os (or a mixture) can be connected • Max. transmission length of 12 km via 2-wire copper cable • 48.8 mm design width CANopen® 2 A at UL TWIN-COMBICON connection Incl. CLIPFIX 35 end bracket 85 mm design width 16 inputs, 24 V DC 16 outputs, 24 V DC, 500 mA 2 and 3-wire connection D-SUB connection 156 mm design width Wireless IO Order No. 2884208 Order No. 2884509 Order No. 2884282 ILB BT ADIO MUX-OMNI ILB BT ADIO MUX-PANEL ILB BT ADIO 2/2/16/16 • • • • • • • • • • • • • • • • • Wireless IO device • Bluetooth 1.2 (16 dBm transmission power, adjustable) • Wireless access via FL BT MOD IO AP (Order No. 2884758) or FLM BT BS 3 (Order No. 2736770) • 16 digital inputs • 16 digital outputs • 2 analog inputs • 2 analog outputs • 95 mm design width Wireless point-to-point transmission OMNI omnidirectional antenna Bluetooth 1.2 (16 dBm transmission power) 16 digital inputs 16 digital outputs 2 analog inputs 2 analog outputs 95 mm design width Wireless point-to-point transmission PANEL directional wireless antenna Bluetooth 1.2 (12 dBm transmission power) 16 digital inputs 16 digital outputs 2 analog inputs 2 analog outputs 95 mm design width PHOENIX CONTACT 23 Inline controllers – class 100 high-performance controllers Order No. 2700973 Order No. 2700974 Order No. 2700975 Order No. 2700976 Order No. 2700977 ILC 131 ETH ILC 151 ETH ILC 171 ETH ILC 191 ETH ILC 151 GSM/GPRS • Typical processing speed of 1.7 ms for 1 K instructions • 192 kB program memory • 192 kB data memory • 8 kB retentive data memory • 1 Ethernet interface • 8 digital inputs • 4 digital outputs • 80 mm design width • Typical processing speed of 1.5 ms for 1 K instructions • 256 kB program memory • 256 kB data memory • 8 kB retentive data memory • 1 Ethernet interface • 8 digital inputs • 4 digital outputs • 80 mm design width • Typical processing speed of 1.5 ms for 1 K instructions • 512 kB program memory • 512 kB data memory • 48 kB retentive data memory • 2 Ethernet interfaces • 8 digital inputs • 4 digital outputs • 80 mm design width • Typical processing speed of 1.3 ms for 1 K instructions • 1 MB program memory • 1 MB data memory • 48 kB retentive data memory • 2 Ethernet interfaces • 8 digital inputs • 4 digital outputs • 80 mm design width • Typical processing speed of 1.5 ms for 1 K instructions • 512 kB program memory • 512 kB data memory • 48 kB retentive data memory • Integrated GSM/GPRS modem • 1 Ethernet interface • 16 digital inputs • 4 digital outputs • 80 mm design width Inline controllers – class 300 high-performance controllers Order No. 2988191 Order No. 2876928 Order No. 2876915 Order No. 2985576 Order No. 2985314 ILC 330 PN ILC 350 PN ILC 370 PN 2TX-IB ILC 370 PN 2TX-IB/M ILC 390 PN 2TX-IB • Typical processing speed of 0.7 ms for 1 K instructions • 750 kB program memory • 1.5 MB data memory • 64 kB retentive data memory • 1 PROFINET interface (10/100) • 12 digital inputs • 4 digital outputs • 182 mm design width • Typical processing speed of 0.5 ms for 1 K instructions • 1 MB program memory • 2 MB data memory • 64 kB retentive data memory • 1 PROFINET interface (10/100) • 12 digital inputs • 4 digital outputs • 182 mm design width • Typical processing speed of 0.3 ms for 1 K instructions • 2 MB program memory • 4 MB data memory • 96 kB retentive data memory • 2 PROFINET interfaces (10/100) • 1 INTERBUS interface (slave) • 12 digital inputs • 4 digital outputs • 182 mm design width • Maritime approval • Typical processing speed of 0.3 ms for 1 K instructions • 2 MB program memory • 4 MB data memory • 96 kB retentive data memory • 2 PROFINET interfaces (10/100) • 1 INTERBUS interface (slave) • 12 digital inputs • 4 digital outputs • 182 mm design width • Typical processing speed of 0.2 ms for 1 K instructions • 2 MB program memory • 4 MB data memory • 96 kB retentive data memory • 2 PROFINET interfaces (10/100) • 1 INTERBUS interface (slave) • 12 digital inputs • 4 digital outputs • 182 mm design width 24 PHOENIX CONTACT Power and segment terminals Order No. 2861331 Order No. 2862136 Order No. 2862152 Order No. 2863779 Order No. 2861454 IB IL 24 PWR IN-PAC IB IL 24 PWR IN/2-FPAC IB IL 24 PWR IN/2-FD-PAC IB IL 24 PWR IN/2-FDF-PAC IB IL 120 PWR IN-PAC Power terminal • 24 V DC (UM, US) • 8 A power supply (at UM, US) • 12.2 mm design width Power terminal • 24 V DC (UM, US) • With fuse • 6 A power supply (at UM, US) • 12.2 mm design width Power terminal • 24 V DC (UM, US) • With fuse and diagnostics (UM, fuse) • 4 A power supply (at UM, US) • 12.2 mm design width Power terminal • 24 V DC (UM, US) • With fuse and diagnostics (fuse) • 4 A power supply (at UM, US) • 12.2 mm design width Power terminal • 120 V AC • Incl. distance terminal • 8 A power supply (at UM) • 36.6 mm design width (24.4 mm + 12.2 mm) Order No. 2861535 IB IL 230 PWR INPAC Order No. 2878971 IB IL 230 PWR IN/FD-PAC Order No. 2862987 IB IL PD 24V-PAC Order No. 2862990 IB IL 24 PD GND-PAC Order No. 2861674 IB IL 24 PWR IN/RPAC Power terminal • 230 V AC • Incl. distance terminal • 8 A power supply (at UM) • 36.6 mm design width (24.4 mm + 12.2 mm) Power terminal • 230 V AC • With fuse and diagnostics • Incl. distance terminal • 8 A power supply (at UM) • 36.6 mm design width (24.4 mm + 12.2 mm) Potential distributor terminal • 24 V DC (from US) • 8 contacts • 12.2 mm design width Potential distributor terminal • GND • 8 contacts • 12.2 mm design width Boost terminal for communications power and I/O voltage (logic up to 2 A) • UL, UANA, UM, US • 8 A power supply (at UM, US) • 48.8 mm design width Order No. 2693020 IB IL 24 PWR IN/R/L0,8 A-PAC Order No. 2861344 IB IL 24 SEG-PAC Order No. 2861373 IB IL 24 SEG/F-PAC Order No. 2861904 IB IL 24 SEG/F-D-PAC Order No. 2861409 IB IL 24 SEG-ELF-PAC Boost terminal for communications power • UL • 0.8 A power supply (at UL) • 12.2 mm design width Segment terminal • 24 V DC • 8 A power supply (at US) • 12.2 mm design width Segment terminal • 24 V DC • With fuse • 6 A power supply (at US) • 12.2 mm design width Segment terminal • 24 V DC • With fuse and diagnostics • 6 A power supply (at US) • 12.2 mm design width Segment terminal • 24 V DC • With electronic fuse and diagnostics • 2.5 A power supply (at US) • 12.2 mm design width PHOENIX CONTACT 25 Digital input terminal Order No. 2861917 Order No. 2861548 Order No. 2861483 Order No. 2861234 IB IL 120 DI 1-PAC IB IL 230 DI 1-PAC IB IL 24 DI 2-NPN-PAC IB IL 24 DI 4-PAC • • • • • • • • • • • • • • • • • 1 input 120 V AC 3-wire connection 12.2 mm design width 1 input 230 V AC 3-wire connection 12.2 mm design width 2 inputs 24 V DC 4-wire connection NPN-wired 12.2 mm design width Order No. 2700173 Order No. 2861247 Order No. 2862204 IB IL 24 DI8/HD-PAC IB IL 24 DI 8-PAC IB IL 24 DI 8/T2-PAC • • • • • • • • • • • • 8 inputs 24 V DC Single-wire connection 12.2 mm design width 8 inputs 24 V DC 4-wire connection 48.8 mm design width 4 inputs 24 V DC 3-wire connection 12.2 mm design width 8 inputs 24 V DC 4-wire connection Input according to EN 61131-2/ type 2 • 48.8 mm design width Order No. 2861250 Order No. 2863520 Order No. 2862835 Order No. 2878243 IB IL 24 DI 16-PAC IB IL 24 DI 16-NPN-PAC IB IL 24 DI 32/HD-PAC IB IL 24 DI 32/HD-NPN-PAC • • • • • • • • • • • • • • • • • • 16 inputs 24 V DC 3-wire connection 48.8 mm design width 26 PHOENIX CONTACT 16 inputs 24 V DC 3-wire connection NPN-wired 48.8 mm design width 32 inputs 24 V DC Single-wire connection 48.8 mm design width 32 inputs 24 V DC Single-wire connection NPN-wired 48.8 mm design width Digital output terminal Order No. 2861920 Order No. 2861263 Order No. 2861496 Order No. 2861616 IB IL DO 1 AC-PAC IB IL 24 DO 2-2A-PAC IB IL 24 DO 2-NPN-PAC IB IL 24 EDO 2-PAC • • • • • • • • • • • • • • • • • 1 output 12 - 253 V AC, 500 mA 3-wire connection 12.2 mm design width 2 outputs 24 V DC, 2 A 4-wire connection 12.2 mm design width Order No. 2861276 IB IL 24 DO 4-PAC Order No. 2861658 IB IL 24 DO 4 AC-1A-PAC • • • • • • • • 4 outputs 24 V DC, 500 mA 3-wire connection 12.2 mm design width 2 outputs 24 V DC, 500 mA 4-wire connection NPN-wired 12.2 mm design width 2 outputs 24 V DC, 500 mA Parameterizable output behavior 12.2 mm design width 4 outputs 12 - 253 V AC, 1 A 3-wire connection 48.8 mm design width Order No. 2700172 Order No. 2861289 Order No. 2861603 Order No. 2863546 IB IL 24 DO8/HD-PAC IB IL 24 DO 8-PAC IB IL 24 DO 8-2 A-PAC IB IL 24 DO 8-NPN-PAC • • • • • • • • • • • • • • • • • 8 outputs 24 V DC, 500 mA Single-wire connection 12.2 mm design width 8 outputs 24 V DC, 500 mA 4-wire connection 48.8 mm design width 8 outputs 24 V DC, 2 A 4-wire connection 48.8 mm design width Order No. 2861292 Order No. 2862822 Order No. 2878340 IB IL 24 DO 16-PAC IB IL 24 DO 32/HD-PAC IB IL 24 DO 32/HD-NPN-PAC • • • • • • • • • • • • • 16 outputs 24 V DC, 500 mA 3-wire connection 48.8 mm design width 32 outputs 24 V DC, 500 mA Single-wire connection 48.8 mm design width 8 outputs 24 V DC, 1 A 4-wire connection NPN-wired 48.8 mm design width 32 outputs 24 V DC, 500 mA Single-wire connection NPN-wired 48.8 mm design width PHOENIX CONTACT 27 Relay terminals Order No. 2861881 Order No. 2862178 Order No. 2863119 IB IL 24/230 DOR1/W-PAC IB IL 24/230 DOR1/W-PCPAC IB IL 24/48 DOR2/W-PAC • • • • • 1 SPDT relay contact • For switching inductive and capacitive loads • 5 - 253 V AC, 2.6 A • 12.2 mm design width • • • • Order No. 2861878 Order No. 2862181 Order No. 2897716 IB IL 24/230 DOR4/W-PAC IB IL 24/230 DOR4/W-PCPAC IB IL 24/230 DOR4/HC-PAC • • • • • 4 SPDT relay contacts • For switching inductive and capacitive loads • 5 - 253 V AC, 2.6 A • 48.8 mm design width • • • • • 1 SPDT relay contact For switching lamp loads 5 - 253 V AC, 3 A 12.2 mm design width 4 SPDT relay contacts For switching lamp loads 5 - 253 V AC, 3 A 48.8 mm design width Order No. 2861645 IB IL DOR LV-SET-PAC Distance terminals for use with the relay output terminals • 12.2 mm design width 28 PHOENIX CONTACT 2 SPDT relay contacts 5 - 50 V AC 5 - 120 V DC, 2 A 12.2 mm design width 4 relay contacts 5 - 253 V AC Max. 10 A High switch-on current 48.8 mm design width Analog input terminals Order No. 2861302 Order No. 2862149 Order No. 2700459 Order No. 2700458 Order No. 2878447 IB IL AI 2/SF-PAC IB IL AI 2-HART-PAC IB IL AI 4/U-PAC IB IL AI 4/I-PAC IB IL AI 4/EF-PAC • 2 inputs • 0 - 10 V, ±10 V, 0 - 20 mA, ±20 mA, 4 - 20 mA • 16 bits • 12.2 mm design width • 2 electrically isolated inputs for HART-compatible sensors • With power supply • 16 bits • 48.8 mm design width • 4 differential inputs (voltage) • 0 - 10 V, ±10 V • 12 bits • 12.2 mm design width • 4 differential inputs (current) • 0 - 20 mA, 4 - 20 mA • 13 bits • 12.2 mm design width • 4 differential inputs with initiator supply • 0 - 5 V, ±5 V, 0 - 10 V, ±10 V, 0 - 20 mA, ±20 mA, 4 - 20 mA • Overload protection (mA) • Bus synchronous (≥ 1 ms) • 16 bits • 48.8 mm design width Order No. 2861412 Order No. 2861661 IB IL AI 8/SF-PAC IB IL AI 8/IS-PAC • 8 inputs • 0 - 5 V, ±5 V, 0 - 10 V, ±10 V, 0 - 25 V, ±25 V, 0 - 50 V 0 - 20 mA, ±20 mA, 4 - 20 mA, 0 - 40 mA, ±40 mA • Multiplex mode • 16 bits • 48.8 mm design width • 8 inputs with initiator supply • 0 - 20 mA, ±20 mA, 4 - 20 mA, 0 - 40 mA, ±40 mA • Multiplex mode • 16 bits • 48.8 mm design width Analog output terminals Order No. 2861315 Order No. 2863083 Order No. 2861467 Order No. 2700775 Order No. 2878036 IB IL AO 1/SF-PAC IB IL AO 2/SF-PAC IB IL AO 2/U/BP-PAC IB IL AO 2/UI-PAC IB IL AO 4/8/U/BPPAC • 1 output • 0 - 10 V, 0 - 20 mA, 4 - 20 mA • 500 Ω load • Short-circuit-proof • 16 bits • 24.4 mm design width • 2 outputs • 0 - 10 V, 0 - 20 mA, 4 - 20 mA • 500 Ω load • Short-circuit-proof • 16 bits • 48.8 mm design width • • • • • 2 outputs • 0 - 10 V, ±10 V, 0 - 20 mA, ±20 mA, 4 - 20 mA • Short-circuit-proof • 12 bits • 12.2 mm design width • • • • 2 outputs 0 - 10 V, ±10 V 16 bits 12.2 mm design width 4 or 8 outputs 0 - 5 V, ±5 V, 0 - 10 V, ±10 V Short-circuit-proof Defined (fast) shutdown behavior • 16 bits • 48.8 mm design width PHOENIX CONTACT 29 Temperature measurement terminals Order No. 2861360 Order No. 2861328 Order No. 2861386 IB IL 24 TC-PAC IB IL TEMP 2 RTD-PAC IB IL TEMP 2 UTH-PAC Thermistor terminal for evaluating motor PTC thermistors • 1 input • 1 output • 12.2 mm design width • 2 inputs for resistance temperature detectors • 16 bits • 12.2 mm design width • 2 inputs for thermocouples • 16 bits • 12.2 mm design width Order No. 2863915 Order No. 2897402 IB IL TEMP 4/8 RTD-PAC IB IL TEMP 4/8 RTD/EF-PAC • 4 or 8 inputs for resistance temperature detectors with 2/3-wire connection • 16 bits • 48.8 mm design width • 4 or 8 inputs for resistance temperature detectors with 4-wire connection • 16 bits • High precision • 48.8 mm design width Measurement terminals for strain gauges Order No. 2875638 Order No. 2884907 Order No. 2700064 Order No. 2700165 IB IL SGI 2/F-PAC IB IL SGI 2/P-PAC IB IL SGI 1/CAL IB IL SGI EU CALSET • • • • • • 2 inputs for strain gauge • Very precise • RS-485 interface for external display • 48.8 mm design width • 1 input for strain gauge • Can be calibrated by EC type approval • Up to 3000 pitch values • RS-485 interface for external display • 48.8 mm design width • Calibration set, approval-related • Accessories for IB IL SGI 1/CAL 2 inputs for strain gauge Very fast (≥ 1 ms) Bus-synchronous 16 bits 48.8 mm design width 30 PHOENIX CONTACT Communication terminals Order No. 2700893 IB IL RS UNI-PAC Order No. 2861357 IB IL RS 232-PAC Order No. 2878722 IB IL RS 232-PRO-PAC Order No. 2861933 IB IL RS 485/422-PAC Order No. 2863627 IB IL RS 485/422-PROPAC Serial interface • 1 configurable serial input and output channel in RS-232 or RS-485/RS-422 format • Only process data communication • Max. transmission speed of 250 kbaud • 24.4 mm design width Serial interface • 1 serial input and output channel in RS-232 format • Max. transmission speed of 38.4 kbaud • 24.4 mm design width Serial interface • 1 serial input and output channel in RS-232 format • Only process data communication • Max. transmission speed of 38.4 kbaud • 24.4 mm design width Serial interface • 1 serial input and output channel in RS-485/RS-422 format • Max. transmission speed of 38.4 kbaud • 24.4 mm design width Serial interface • 1 serial input and output channel in RS-485/RS-422 format • Only process data communication • Max. transmission speed of 38.4 kbaud • 24.4 mm design width Order No. 2861441 IBS IL 24 RB-T-PAC Order No. 2878117 IB IL 24 RB-LK Order No. 2736903 IB IL 24 FLM-PAC Order No: 2737009 IB IL 24 FLM MULTIPAC Order No. 2897457 IB IL 24 LSKIP-PAC Branch terminal • INTERBUS remote bus branch • 12.2 mm design width Branch terminal • INTERBUS remote bus branch • Fiber optic connection • 24.4 mm design width Branch terminal for connecting a Fieldline Modular M8 or M12 local bus at the end of an Inline station • 12.2 mm design width Branch terminal for connecting a Fieldline Modular M8 local bus at any point in an Inline station • 12.2 mm design width Inline local bus extension terminal • Can be used with IB IL 24 FLM-PAC • 48.8 mm design width Order No. 2897813 Order No. 2897910 Order No. 2897237 Order No. 2701927 IB IL DALI/PWR-PAC IB IL DALI/PAC SRC-RS485 EVC IB IL MBUS-PAC DALI terminals • Single-channel DALI master • Integrated DALI power supply unit • Safe electrical isolation • 61 mm design width DALI terminals • Single-channel DALI master • Extension for IB IL DALI/PWR-PAC • 12.2 mm design width EnOcean wireless receiver for connecting to IB IL RS 485/422-PRO-PAC M-bus terminal • Single-channel M-bus master • Process data communication only • Up to 30 M-bus devices can be connected • Transmission speed of 19.2 kbaud • 24.4 mm design width PHOENIX CONTACT 31 Communication master Order No. 2700630 Order No. 2700196 Order No. 2862717 Order No. 2736628 Order No. 2692720 IB IL PB-MA-PAC IB IL CAN-MA-PAC IB IL IOL 4 DI 12-PAC ASI MA IL UNI IB IL IFS-MA-PAC PROFIBUS master • PROFIBUS DP V0 master/slave • Max. transmission speed of 12 Mbps • Serial interface (S port) incl. memory stick • 48.8 mm design width CAN master • CAN 2.0A and CAN 2.0B • Transmission speed of 10 kbps to 1 Mbps • Serial interface (S port) incl. memory stick • 12.2 mm design width IO-Link • 4 IO-Link channels • 12 digital inputs, 24 V DC • 48.8 mm design width AS-i master • Inline/AS-i master, universal for all bus couplers • AS-i specification 2.1 • 73.2 mm design width IF system bus master • Integration of up to 8 EMM and EEM modules • Serial interface (S port) incl. memory stick • Up to 31 measured values and 16 manipulated variables • 24.4 mm design width Terminals for open and closed-loop control Order No. 2861865 Order No. 2861852 Order No. 2897020 Order No. 2861632 IB IL SSI-PAC IB IL CNT-PAC IB IL DI 8/S0-PAC IB IL PWM/2-PAC Positioning terminal • Single-axis point-to-point control for absolute encoders with SSI interface • Rapid motion/creeping motion principle • 3 digital inputs • 4 digital outputs • 48.8 mm design width Counter • 1 counter input • 1 control input • 1 output • Max. counting frequency of 100 kHz • 24-bit binary counter • Pulse generator • 24.4 mm design width Counter • 8 inputs for S0 pulse encoder • 32-bit counter range • 48.8 mm design width PWM terminal • Pulse width modulation • 2 channels • Pulse/direction interface for controlling step motor power sections • Max. 50 kHz (5 V) • Max. 500 Hz (24 V) • 24.4 mm design width Order No. 2819574 IB IL SSI-IN-PAC Order No. 2861755 IB IL INC-IN-PAC Order No. 2861768 IB IL IMPULSE-INPAC Position detection terminal • Reads positions of absolute encoders with SSI interface • Input resolution max. 25 bits • 12.2 mm design width Position detection terminal • Reads positions of incremental encoders • 25-bit position actual value • 24.4 mm design width Position detection terminal • Reads positions from magnetostrictive length measuring systems with start/stop interface • Position resolution of 5 μm • 12.2 mm design width 32 PHOENIX CONTACT Energy/power measurement terminal Order No. 2700965 IB IL PM 3P/N/EF-PAC Energy/power measurement terminal • 3 phases plus neutral conductor connection • Direct current acquisition (1 A or 5 A) • Max. outer conductor voltage of 690 V AC (L-L) • 48.8 mm design width Power-level terminals Order No. 2727365 Order No. 2727352 Order No. 2727378 IB IL 400 MLR 1-8A IB IL 400 ELR 1-3A IB IL 400 ELR R-3A Direct starter • Electromechanical load relay • Single-channel direct starter • Up to 3.7 KW/400 V AC • 63 mm design width Direct starter • Electronic load relay • Single-channel direct starter • Up to 1.5 KW/400 V AC • 63 mm design width Reversing starter • Electronic load relay • Single-channel reversing starter • Up to 1.5 KW/400 V AC • 63 mm design width Corresponding accessories can be found in our online catalog www.phoenixcontact.net/products Intrinsically safe Inline terminals (Ex-i) Order No. 2869910 Order No. 2869911 Order No. 2869912 Order No. 2869913 IB IL EX-IS PWR IN-PAC IB IL EX-IS DIO 4/NAM-PAC IB IL EX-IS AIO 4/EF-PAC IB IL EX-IS TEMP 4 RTD/ TC-PAC • • • • • • 4 configurable I/O channels • 2-wire connection • NAMUR sensors supported (EN 60947-5-6) • Single-channel diagnostics • 8.2 V sensor supply • 48.8 mm design width • 4 configurable I/O channels • 2/3-wire connection • Input: 0 - 10 V, 0 - 20 mA, 4 - 20 mA • Output: 0 - 20 mA, 4 - 20 mA • Optional passive output • Module-based electrical isolation • Single-channel diagnostics • 48.8 mm design width • 4 configurable I/O channels • 2/3-wire connection • RTD inputs: Pt, Ni (DIN 100, 200, 500, 1000) • TC inputs: J, K, E, R, S, T • Module-based electrical isolation • Single-channel diagnostics • 48.8 mm design width 24 V DC (UEx) 1000 mA (max.) at UEx Diagnostic LEDs Electronic overload protection 48.8 mm design width PHOENIX CONTACT 33 Safety terminals Order No. 2700606 Order No. 2701625 IB IL 24 LPSDO 8 V2-PAC IB IL 24 LPSDO 8 V3-PAC Safe logic modules for SafetyBridge technology • Connection to 5 safe I/O modules • 4 safety-related two-channel outputs each or 8 safety-related single-channel outputs each • 24 kB logic memory • 24 V DC, 2 A (per channel) • Max. PL e acc. to EN ISO 13849-1 and SIL 3 acc. to IEC 61508 (EN IEC 62061) • 48.8 mm design width Safe logic modules for SafetyBridge technology • Connection to 16 safe I/O modules • 4 safety-related two-channel outputs each or 8 safety-related single-channel outputs each • 60 kB logic memory • 24 V DC, 2 A (per channel) • Max. PL e acc. to EN ISO 13849-1 and SIL 3 acc. to IEC 61508 (EN IEC 62061) • 48.8 mm design width Order No. 2985688 Order No. 2700994 IB IL 24 PSDI 8-PAC IB IL 24 PSDI 16-PAC Safe input I/O modules for SafetyBridge technology, INTERBUS-Safety, and PROFIsafe • 4 safety-related two-channel inputs each or 8 safety-related single-channel inputs each • 2 clock outputs for supplying inputs UT1 and UT2 • Max. PL e acc. to EN ISO 13849-1 and SIL 3 acc. to IEC 61508 (EN IEC 62061) • 48.8 mm design width Safe input I/O modules for PROFIsafe and SafetyBridge technology • Can be used with IB IL 24 LPSDO 8 V3-PAC • 4 safety-related two-channel inputs each or 8 safety-related single-channel inputs • 2 clock outputs for supplying inputs UT1 and UT2 • Max. PL e acc. to EN ISO 13849-1 and SIL 3 acc. to IEC 61508 (EN IEC 62061) • 48.8 mm design width Order No. 2985631 Order No. 2985864 Order No. 2916493 IB IL 24 PSDO 8-PAC IB IL 24 PSDOR 4-PAC IB IL 24 PSDO 4/4-PAC Safe output I/O modules for SafetyBridge technology, INTERBUS-Safety, and PROFIsafe • 4 safety-related two-channel outputs each or 8 safety-related single-channel outputs each • 24 V DC, 2 A (per channel) • Max. PL e acc. to EN ISO 13849-1 and SIL 3 acc. to IEC 61508 (EN IEC 62061) • 48.8 mm design width Safe output I/O modules for SafetyBridge technology, INTERBUS-Safety, and PROFIsafe • 2 safety-related two-channel relays or 4 safety-related single-channel relays (2 floating contacts each) • 2 readback inputs for recording external circuit breakers • 2 clock outputs for supplying the readback inputs • Max. PL e acc. to EN ISO 13849-1 and SIL 3 acc. to IEC 61508 (EN IEC 62061) • 73.2 mm design width Safe output I/O modules for SafetyBridge technology, INTERBUS-Safety, and PROFIsafe • 4 safe positive switching and 4 safe negative switching digital outputs • 24 V DC, 2 A (per channel) • Max. PL e acc. to EN ISO 13849-1 and SIL 3 acc. to IEC 61508 (EN IEC 62061) • 48.8 mm design width 34 PHOENIX CONTACT Product overview Machine Edition (ME) Inline controllers – class 100 compact controllers Order No. 2700075 Order No. 2700074 ILC 191 ME/INC ILC 191 ME/AN • • • • • • • • • • • • • • • • • • • • • • • • Typical processing speed of 1.3 ms for 1 K instructions 1 MB program memory 1 MB data memory 48 kB retentive data memory 2 Ethernet interfaces 1 RS-485/RS-422 interface 1 two-channel pulse/direction interface and PWM (before digital) 8 digital inputs (event task compatible) 4 digital outputs 2 inputs for incremental encoder 2 fast counter inputs (max. 200 kHz) 164 mm design width DI Typical processing speed of 1.3 ms for 1 K instructions 1 MB program memory 1 MB data memory 48 kB retentive data memory 2 Ethernet interfaces 1 RS-485/RS-422 interface 1 two-channel pulse/direction interface and PWM (before digital) 8 digital inputs (event task compatible) 4 digital outputs 2 analog inputs 2 analog outputs 164 mm design width DO Order No. 2863928 Order No. 2897156 Order No. 2863931 Order No. 2897253 IB IL 24 DI 4-ME IB IL 24 DI 16-ME IB IL 24 DO 4-ME IB IL 24 DO 16-ME • • • • • • • • • • • • • • • • • • • • • • • • 4 inputs 24 V DC 3-wire connection Short plug 12.2 mm design width Pack of 4 AI 16 inputs 24 V DC 3-wire connection Short consecutively numbered plugs 48.8 mm design width Pack of 4 4 outputs 24 V DC, 500 mA 3-wire connection Short plugs 12.2 mm design width Pack of 4 16 outputs 24 V DC, 500 mA 3-wire connection Short consecutively numbered plugs 48.8 mm design width Pack of 4 AO Order No. 2863944 Order No. 2863957 IB IL AI 2/SF-ME IB IL A0 2/U/BP-ME • 2 inputs • 3-wire connection • 0 - 10 V, ±10 V, 0 - 20 mA, ±20 mA, 4 - 20 mA • 12 bits • Without shield connection • 12.2 mm design width • • • • • • 2 outputs 2-wire connection 0 - 10 V, ±10 V 12 bits Without shield connection 12.2 mm design width PHOENIX CONTACT 35 Product overview Extreme Conditions (XC) Inline controllers – class 100 high-performance controllers Order No. 2701034 ILC 131 ETH/XC Order No. 2701141 ILC 151 ETH/XC • Typical processing speed of 1.7 ms for 1 K instructions • 192 kB program memory • 192 kB data memory • 8 kB retentive data memory • 1 Ethernet interface • 8 digital inputs • 4 digital outputs • Extended temperature range of -40°C to +60°C • 80 mm design width • Typical processing speed of 1.5 ms for 1 K instructions • 256 kB program memory • 256 kB data memory • 8 kB retentive data memory • 1 Ethernet interface • 8 digital inputs • 4 digital outputs • Extended temperature range of -40°C to +60°C • 80 mm design width Ethernet Fieldbuses Modbus TCP (UDP) Order No. 2701388 Order No. 2701150 Order No. 2701151 IL ETH BK DI8 DO4-2TX-XC-PAC IBS IL 24 BK-T/U-XC-PAC IBS IL 24 RB-T-XC-PAC • • • • • • • • • • • • • • Branch terminal • INTERBUS remote bus branch • Extended temperature range of -40°C to +60°C • 12.2 mm design width Modbus TCP (UDP) HTTP, TFTP, BootP, SNMP 8 inputs, 24 V DC 4 outputs, 500 mA 0.8 A at UL RJ45 connection Extended temperature range of -40°C to +60°C 80 mm design width Communication master Order No. 2701160 IB IL CAN-MA-XC-PAC CAN master • CAN 2.0A and CAN 2.0B • Transmission speed of 10 kbps to 1 Mbps • Serial interface (S port) incl. memory stick • Extended temperature range of -40°C to +60°C • 12.2 mm design width 36 PHOENIX CONTACT INTERBUS Incl. branch bus terminal support 2 A at UL Bus connection via Inline plug Extended temperature range of -40°C to +60°C 48.8 mm design width Power and segment terminals Order No. 2701162 Order No. 2701298 Order No. 2701161 Order No. 2701163 IB IL 24 PWR IN/2-F-XC-PAC IB IL 24 PWR IN/R-XC-PAC IB IL 24 PWR IN-XC-PAC IB IL 24 SEG/F-XC-PAC Power terminal • 24 V DC (UM, US) • With fuse • 6 A power supply (at UM, US) • Extended temperature range of -40°C to +60°C • 12.2 mm design width Power terminal • 24 V DC (UM, US) • 8 A power supply (at UM, US) • Extended temperature range of -40°C to +60°C • 12.2 mm design width Segment terminal • 24 V DC • With fuse • 6 A power supply (at US) • Extended temperature range of -40°C to +60°C • 12.2 mm design width Boost terminal for communications power and I/O voltage (logic up to 2 A) • UL, UANA, UM, US • 8 A power supply (at UM, US) • Extended temperature range of -40°C to +60°C • 48.8 mm design width Digital input terminals Order No. 2701152 Order No. 2701212 Order No. 2701154 IB IL 24 DI 4-XC-PAC IB IL DI 8/HD-XC-PAC IB IL DI 16/XC-PAC • • • • • • • • • • • • 4 inputs 24 V DC 3-wire connection Extended temperature range of -40°C to +60°C • 12.2 mm design width 8 inputs 24 V DC Single-wire connection Extended temperature range of -40°C to +60°C • 12.2 mm design width 16 inputs 24 V DC 3-wire connection Extended temperature range of -40°C to +60°C • 48.8 mm design width Digital output terminals Relay terminal Order No. 2701155 Order No. 2701213 Order No. 2701156 Order No. 2701214 IB IL DO 4-XC-PAC IB IL DO 8/HD-XC-PAC IB IL DO 16/XC-PAC IB IL 24/48 DOR 2/W-XC-PAC • • • • • • • • • • • • • • • • 4 outputs 24 V DC, 500 mA 3-wire connection Extended temperature range of -40°C to +60°C • 12.2 mm design width 8 outputs 24 V DC, 500 mA Single-wire connection Extended temperature range of -40°C to +60°C • 12.2 mm design width 16 outputs 24 V DC, 500 mA 3-wire connection Extended temperature range of -40°C to +60°C • 48.8 mm design width 2 SPDT relay contacts 5 - 50 V AC 5 - 120 V DC, 2 A Extended temperature range of -40°C to +60°C • 12.2 mm design width PHOENIX CONTACT 37 Analog input terminals Order No. 2701157 Order No. 2701215 Order No. 2701159 IB IL AI 2/SF-XC-PAC IB IL AI 4/EF-XC-PAC IB IL AI 8/SF-XC-PAC • • • • • • 4 differential inputs with initiator supply • 0 - 5 V, ±5 V, 0 - 10 V, ±10 V, 0 - 20 mA, ±20 mA, 4 - 20 mA • Overload protection (mA) • Bus synchronous (≥ 1 ms) • 16 bits • Extended temperature range of -40°C to +60°C • 48.8 mm design width • 8 inputs • 0 - 5 V, ±5 V, 0 - 10 V, ±10 V, 0 - 25 V, ±25 V, 0 - 50 V 0 - 20 mA, ±20 mA, 4 - 20 mA, 0 - 40 mA, ±40 mA • Multiplex mode • 16 bits • Extended temperature range of -40°C to +60°C • 48.8 mm design width Order No. 2701219 Order No. 2701389 Order No. 2701164 IB IL AO 1/SF-XC-PAC IB IL AO 2/UI-XC-PAC IB IL AO 4/8/U/BP-XC-PAC • • • • • • • • • • • • • • • • • • • • 2 inputs 0 - 10 V, ±10 V, 0 - 20 mA, ±20 mA, 4 - 20 mA 16 bits Extended temperature range of -40°C to +60°C 12.2 mm design width Analog output terminals 1 output 0 - 10 V, 0 - 20 mA, 4 - 20 mA 500 Ω load Short-circuit-proof 16 bits Extended temperature range of -40°C to +60°C 24.4 mm design width 2 outputs 0 - 10 V, ±10 V, 0 - 20 mA, ±20 mA 4 - 20 mA Short-circuit-proof 12 bits Extended temperature range of -40°C to +60°C 12.2 mm design width 4 or 8 outputs 0 - 5 V, ±5 V, 0 - 10 V, ±10 V Short-circuit-proof Defined (fast) shutdown behavior 16 bits Extended temperature range of -40°C to +60°C 48.8 mm design width Temperature measurement terminals Order No. 2701217 IB IL TEMP 2 RTD-XC-PAC Order No. 2701216 IB IL TEMP 2 UTH-XC-PAC Order No. 2701218 IB IL TEMP 4/8 RTD-EF-XC-PAC • • • • • • • • • 4 or 8 inputs for resistance temperature detectors with 4-wire connection • 16 bits • High precision • Extended temperature range of -40°C to +60°C • 48.8 mm design width 2 inputs for resistance temperature detectors 16 bits Extended temperature range of -40°C to +60°C 12.2 mm design width 38 PHOENIX CONTACT 2 inputs for thermocouples 16 bits Extended temperature range of -40°C to +60°C 12.2 mm design width Product overview Accessories for the Inline I/O system Order No. 2900889 Order No. 2304128 Order No. 2302751 Order No. 2302777 FLKM 14-PA-INLINE /DIO 8 FLKM 14-PA-INLINE /IN 8 FLKM 14-PA-INLINE /IN 16 FLKM 14-PA-INLINE 32 Order No. 2304131 Order No. 2302764 FLKM 14-PA-INLINE /OUT 8 FLKM 14-PA-INLINE /OUT 16 VARIOFACE front adapter for 8-channel Inline HD modules VARIOFACE front adapter for 8-channel Inline modules VARIOFACE front adapter for 16-channel Inline modules VARIOFACE front adapter for 32-channel Inline modules Order No. 2799720 Order No. 2758473 Order No. 2761499 see INTERFACE catalog PSM-SET-FSMA/4-KT IBS DSUB 9/L SUBCON 9/F-SH SUBCON-PLUS-PROFIB /… Order No. 2799487 Order No. 2758486 Order No. 2761509 see INTERFACE catalog PSM-SET-FSMA/4-HCS IBS DSUB 9/C SUBCON 9/M-SH SUBCON-PLUS-CAN /… FSMA plugs for INTERBUS fiber optics D-SUB 9 connectors SUBCON D-SUB plugs for INTERBUS SUBCON plugs for PROFIBUS and CAN Order No. 3022276 Order No. 3022218 Order No. 1201662 Order No. 2740850 CLIPFIX 35-5 CLIPFIX 35 E/AL-NS 35 I-L ATP GN Standard end bracket End bracket for CANopen® and DeviceNet™ bus couplers End bracket for use in the event of vibrations End cover plate Order No. 2727501 Order No. 809492 See CLIPLINE catalog Order No. 2742683 IB IL FIELD 2 ESL 62X10 ZBFM 6-… IL CP Order No. 2727515 Order No. 809502 IB IL FIELD 8 ESL 62X46 Inline marking fields Marking sheets for laser printer Zack marker strip marking Coding profile unit pack: 100 profiles with pins PHOENIX CONTACT 39 Always up-to-date, always available to you. Here you‘ll find everything on our products, solutions and service: phoenixcontact.net Product range • I/O systems • Industrial communication technology • Industrial lighting • Installation and mounting material • Marking and labeling • Measurement and control technology • Modular terminal blocks • Monitoring and signaling • PCB terminal blocks and PCB connectors • Plug connectors • Protective devices • Relays • Sensor cables and connectors • Software • Surge protection devices • System cabling for DCS and PLC • Tools • Wireless data communication PHOENIX CONTACT GmbH & Co. KG 32825 Blomberg, Germany Phone: +49 (0) 52 35 3-00 Fax: +49 (0) 52 35 3-4 12 00 phoenixcontact.net ION03-13.000.L3.2013 MNR 52003508/2013-11-15/03 Printed in Germany © PHOENIX CONTACT 2013 • Cables and connectors • Controllers and PLCs • DIN rail power supplies and UPS • Electronic reversing contactors and motor control • Electronics housing • Ethernet networks • Fieldbus components and systems • Functional safety • HMIs and industrial PCs